Woodward easYgen-3000 Series Option Manual

Woodward easYgen-3000 Series Option Manual

For operation with group controller gc (option k51)
Hide thumbs Also See for easYgen-3000 Series:

Advertisement

easYgen-3000 Series
Option Manual
K51 Genset Control
EG3500XTP1/P2 for Operation with Group Controller GC (Option K51)
Software Version 1.15-1
37900A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the easYgen-3000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Woodward easYgen-3000 Series

  • Page 1 Series Option Manual K51 Genset Control EG3500XTP1/P2 for Operation with Group Controller GC (Option K51) Software Version 1.15-1 37900A...
  • Page 2 This manual is no translation but the original Technical Manual. Woodward GmbH Handwerkstrasse 29 70565 Stuttgart Germany Telephone: +49 (0) 711 789 54-510 Fax: +49 (0) 711 789 54-101 E-mail: stgt-info@woodward.com Internet: http://www.woodward.com © 2019 EG3500XTP1/P2 for Operation with Group Controller GC (Option K51) | K51 Genset Control...
  • Page 3: Table Of Contents

    Table of contents Table of contents General information........................4 About This Manual........................4 1.1.1 Depiction Of Notes And Instructions................... 4 Introduction..........................7 Overview............................. 7 Description..........................7 Additional Functionality ......................8 Operation with the Group Controller.................... 8 Application........................... 8 3.2.1 Inhibit uncoordinated dead bus closure GCB................8 3.2.2 Droop configuration........................
  • Page 4: General Information

    Woodward reserves the right to update any portion of this publica‐ tion at any time. Information provided by Woodward is believed to be correct and reliable. However, Woodward assumes no respon‐...
  • Page 5 General information About This Manual > Depiction Of Notes And Ins... WARNING! Read this entire manual and all other publications pertaining to the work to be performed before installing, operating, or servicing this equipment. Practice all plant and safety instructions and pre‐ cautions.
  • Page 6 This publication may have been revised or updated since this copy was produced. To verify that you have the latest revision, be sure to check the Woodward website: http://www.woodward.com/pubs/current.pdf The revision level is shown at the bottom of the front cover after the publication number. The latest version of most publications is available at: http://www.woodward.com/publications...
  • Page 7: Introduction

    Introduction Description Introduction This brief manual must be used together with the standard manuals The following standard manuals are required to install, commission, and operate the easYgen-3500XT Packages P1, P2 with Option K51 and the Group Controller: easYgen-3000XT Series Manual (No. 37580 –...
  • Page 8: Additional Functionality

    Parameter “Application mode” (3444) is fixed to “GCB/LS5.” This is because some functions of the Group Controller bear resemblance to Woodward's LS5 device. (For this reason, in some screens "LS5" will appear, even though there is no LS5.) Parameter "Load share interface”...
  • Page 9: Droop Configuration

    Additional Functionality Application > Droop configuration The K51 easYgenXT (GC mode enabled) which has triggered the "Missing easYgen alarm" delays its dead bus closure depending on its device number. This is cascaded through: (Device number easYgen) x 0.5s. The GC dead bus closure is not delayed, if the "Missing easYgen alarm"...
  • Page 10: Home Screen

    Additional Functionality Communication Management / D... 3.2.3 Home Screen If GC mode is on, it is possible to show the mains data measured by the Group Controller “Mains (GC)” like in the screen below. If this is wished, parameter “4103 Home screen data” must be con‐ figured to “Generator/LS5”...
  • Page 11 Additional Functionality Communication Management / D... Example 1 The following HMI screen shows two easYgen devices taught in: the load share interface is configured as “CAN/Ethernet A”. Device 1 is OK, device 3 is only available on CAN (this means: Ethernet A failure).
  • Page 12 Additional Functionality Communication Management / D... Example 2 This screen shows the Group Controller (device 32) as redundant taught in, but only Ethernet A is intact. EG3500XTP1/P2 for Operation with Group Controller GC (Option K51) | K51 Genset Control 37900A...
  • Page 13 Additional Functionality Communication Management / D... Example 3 This screen shows the Group Controller (device 32) as taught in, but it is not recognized anymore. For this reason, command vari‐ able “02.40 Ä p. 16 Own GC not recognized” becomes active. “02.40 Ä...
  • Page 14: Group Controller Alarms

    Additional Functionality Group Controller alarms Group Controller alarms Handling of Group Controller alarms The alarms of the Group Controller are available in the easYgen as Ä Chapter 3.6 “Logical Command in the easYgen command variables. (Refer to Variables (CV)” on page 16 ) These command variables can be assigned to the “Free Alarms”.
  • Page 15: Parameter Overview

    Additional Functionality Parameter overview Alarm “Interface redundancy error” If the application needs an alarm, where the redundancy of the load share interface is lost, “Free Alarms” may be used. Like the standard easYgen device, the K51 provides 16 free alarms. They can be used to drive additional alarms from the LM command var‐...
  • Page 16: Logical Command Variables (Cv)

    Additional Functionality Logical Command Variables (C... Parameter Setting Description Location range [Default] The GC mode is enabled. The easYgen expects to see a GC device on CAN3 / Ethernet A interface. 9924 Load share The communication interface Note: This parameter is Parameter Configura‐...
  • Page 17 Additional Functionality Logical Command Variables (C... Group 04: Application conditions: Name Function Note 04.71 10847 GC LDSS Start The load dependent start/stop TRUE as long as the load dependent start/stop func‐ request (LDSS) function of the GC requests tion of the GC requests an engine start. an engine start.
  • Page 18 Additional Functionality Logical Command Variables (C... Name Function Note 22.12-22 Reserved 22.17 GC GGB fail to GC GGB fail to close TRUE if the GC has attempted to close the GGB for close the configured maximum number of attempts and failed.
  • Page 19: Index

    Index Index Alarms ....... . . 14 Communication between devices ... . 10 Dead busbar closure .
  • Page 20 EG3500XTP1/P2 for Operation with Group Controller GC (Option K51) | K51 Genset Control 37900A...
  • Page 22 Woodward GmbH Handwerkstrasse 29 - 70565 Stuttgart - Germany Phone +49 (0) 711 789 54-510 Fax +49 (0) 711 789 54-101 stgt-info@woodward.com...