Display screen is blank or difficult to read
Cause
Brightness set too low.
Power saving has been activated
(monitor is blank).
The cursor does not correctly follow the pen movements
Cause
Pin incorrectly calibrated
Infrared data transfer is not working
Cause
No visual contact between Tablet PC
and infrared receiver.
Distance between Tablet PC and
infrared receiver > 1 m.
The infrared receiver on the Tablet
PC is not in the effective field (approx.
30° horizontal and approx. 15°
vertical) of the infrared interface on
the other device.
The other device does not comply
with the IrDA standard, revision 1.1 or
1.0.
A26391-K279-Z220-1-7619, edition 1
Troubleshooting
►
Press the Fn button twice to open the Fujitsu
Menu.
This menu contains the tab for changing the brightness.
►
Tap on the display screen to reactivate the display.
Note that this is a normal power-saving feature.
Troubleshooting
Windows XP:
►
Calibrate the pen under Tablet and Pen Settings in the
Control Panel, see "Calibrating the pen".
Windows Vista:
►
Calibrate the pen under Mobile PC - Tablet PC
Settingsin the Control Panel, see "Calibrating the
pen".
►
Check whether the battery is installed correctly in its
compartment.
►
Switch the notebook on.
Troubleshooting
►
Ensure visual contact between Tablet PC and
infrared receiver.
►
Reduce the distance between the Tablet PC and the
infrared receiver.
►
Check the effective field.
►
Only use devices that comply with the IrDA
standard, revision 1.1 or 1.0.
Troubleshooting and tips
61