Changing Camera Settings Using the RM-P2580
PANIC ALARM SET Screen
Used for settings related to the panic alarm input. (
Item
DURATION
Sets the duration of the alarm mode operation
when alarm signal is input.
When set to SERIES, alarm mode operation continues.
Note:
When used in a system with the RM-P2580, this
setting becomes invalid. Make the setting using
the RM-P2580 ALARM TIME option.
POLARITY
Sets the polarity of the alarm input.
MAKE:
BREAK: Alarm condition generated when
POSITION
Sets the camera position at the time of alarm
input.
MODE
Sets whether or not manual operation should
be accepted during alarm operation.
ALARM: Manual operation not accepted dur-
MANUAL: Manual operation is accepted also
Note:
When used in a system with the RM-P2580, this
setting becomes invalid. The mode becomes the
ALARM priority mode.
FACTORY SETTINGS Screen
Used for returning all settings to the default values.
Item
Used to return menu settings to the factory
FACTORY
settings.
SETTINGS
YES: Returns settings to the factory settings.
NO: Settings are not returned to the factory
settings.
Memo:
When YES is selected and the SET button is
pressed, after "EXECUTING" has been
displayed for about 10 seconds on the screen,
"DATA CLEARED" is shown for about 3 seconds.
Do not turn off the power during this interval.
24
Function
Alarm condition generated when
MAKE connected.
BREAK connected.
ing alarm operation.
during alarm operation.
Function
See "PANIC ALARM" on page 32.)
Variable
range
5, 6, 7, 8, 9,
10, 15, 20,
25, 30,
60 s,
SERIES
MAKE
BREAK
HOME
POS 1 to
POS 15
ALARM
MANUAL
Variable
range
YES
NO
Factory
setting
10 s
MAKE
POS 1
ALARM
Factory
setting
NO
Need help?