Divar | Installation Manual | Menu system
>>> Disk Full Alarm Setup
•
Set the percentage of used disk space at which the disk-full warning
message is displayed.
•
Set the time in minutes before the disk is full at which a disk-full
alarm is generated.
•
Select the number of the output relay that is activated when a disk-
full alarm is generated.
•
Enable the beeper to activate it when a disk-full alarm is generated.
>> PLAYBACK SETUP
Use the Playback Setup list to block the playback of recordings from particular
cameras after a specified period of time.
•
Choose from No Block, 1 to 7 days, 14 days, 21 days, 28 days or 31 days.
When the specified time has elapsed, the recordings of that camera from
before that time cannot be played back.
>> EVENT SETUP
Use the Event Setup menu to specify the display behavior for an input, detected
motion or video loss.
•
Set the Alarm Dwell Time to select the period during which the output
relay and the beeper remain active after activation.
•
Set the Trigger Dwell Time to select the period during which the
triggered view mode is displayed after activation.
•
The value Follows activates the beeper and relay or view, only as long as
the event is present.
>>> Input Setup
•
To restore the default input settings select the Clear Input Settings
item.
•
Select the Display Monitor submenu to choose the view mode and
cameras to be displayed when an input is activated.
•
Select the number of the output relay to be activated when any
alarm input is activated.
•
Enable the beeper to activate it when an alarm input is activated.
Bosch Security Systems
•
Select the Input Name submenu to assign a name to each of the 16
Divar inputs.
•
If a Bilinx camera is connected, select the Alarm Input Mapping
submenu to associate the alarm input of a Bilinx camera with one of
the 16 Divar inputs. ***
•
If an alarm panel is connected to the RS232 port and enabled,
select the Alarm Input Mapping submenu to associate alarms from
the alarm panel with the 16 Divar inputs.
•
Select the Auto-protect submenu to choose automatic protection of
video clips activated by a specified input.
Display mon A
•
Select the input number (1 to 16) for which you wish to set the view
mode.
•
If you have controllable cameras, set a camera number and a pre-
position number. The specified camera goes to this position when
the numbered input is activated.
•
Select a view mode. Only view modes that are enabled can be
selected.
•
If you have selected the full-screen or quad view mode, select the
cameras to be displayed.
Display mon B
•
Select the input number (1 to 16) for which you wish to set the view
mode.
•
If you have controllable cameras, set a camera number and a pre-
position number. The specified camera goes to this position when
the numbered input is activated.
•
Select up to four cameras to be displayed in sequence.
Alarm Input Mapping
•
Only shown if alarm panel is connected and enabled.
•
The control console type is displayed.
•
For each of the 16 alarm inputs, select either the physical Divar
input (the physical input is automattically mapped to its
EN | 5-10