Content Components The posts Fixators and tools The Nylofor panels Rolltop and Paladin panels Nylofor City system Installation Foundations Installation of posts & panels Installation of Nylofor City system 18/05/2020 – Nylofor / Twilfix - Installation manual ®...
The posts are equipped with M8 inserts to attach the panels with clamps and security bolts Additionally inserts for panel stepping are available Each post is fitted with a PP post cap with Betafence logo Posts with inserts in 2 adjacent sides are available to make corners...
1. Components Fixators and tools PA fixators with caps, to be attached with M8x40 – security bolts (ISO 7380) Different fittings are available, depending on the – type of panel being installed – – 2D Super – – – 3D INT* –...
Page 6
1. Components Fixators and tools Metal fixators for panel Rolltop are to be attached with – M8x40 security bolts Tri-Lobe Bolt (Countersunk Head) Metal cover for Paladin panel – 18/05/2020 – Nylofor / Twilfix ® - Installation manual...
1. Components The Nylofor panels – Range: Type 3D Pro Super Super Height 1,03 – 1,03 – 1,03 – 1,63 – 0,63 – 1,03 – 2,43 m 2,43 m 2,03 m 2,43 m 2,03 m 2,43 m Width 2,5 m 2,5 m 2,5 m 2,5 m...
Page 8
1. Components The Rolltop & Paladin panels – Range: Type Roll top Paladin Height 900; 1200; 1500; 1800; 2400 mm 1240; 1850; 2038; 2445 mm Width H: 5mm V: 5mm H: 4mm V: 3mm Wire dia Mesh size 150 x 50mm 50,8x50,8 ;...
The posts are pre-fitted with the appropriate holes and inserts for the fixation of the panels Posts are covered with plastic post cap with Betafence logo Nylofor City is always installed with Nylofor F panels. The panels are mounted with the pins on the bottom...
Page 10
1. Components Nylofor City system Nylofor City is installed with one metal clamp on top to hold the rail, the other clamps are standard Nylofor F clamps (PA) — There are 3 types of metal clamps: an intermediate clamp, a left corner clamp and a right corner clamp.
2. Installation Foundations To obtain the best result, it is advisable to level the ground over the whole length of the fence For correct positioning, maintain the centre-centre distances. (with a tolerance of +/- 5 mm) The distance is determined the type of panel being installed Panel type Centre-Centre distance Nylofor...
2. Installation Installation of posts & panels Installation principle: when placing square posts, first all the posts can be placed and then the panels can be attached. ALIGNING THE POSTS Installation on an even surface Place a pin before the first post of the fence and another behind the last post.
Page 13
2. Installation Installation of posts & panels PLACEMENT OF THE POSTS (USE A TEMPLATE) A template makes it much easier to place the posts correctly: a mould of 2530 mm* needs to be used to see if the posts are placed at a correct distance (measured center-center, with a tolerance of +/- 5 mm) The template must be made by the installer and must have 2...
Page 14
2. Installation Installation of posts & panels INSTALLATION OF THE PANELS Join two panels together on an intermediate post at the correct height Place a clamp in the upper insert of the post and tighten the security bolt halfway Now place an additional clamp in the lower insert and tighten the security bolt halfway Repeat this procedure for all intermediate posts and finish with the corner post...
Page 15
2. Installation Installation of posts & panels MAKING CORNERS – RIGHT ANGLE Only for Nylofor 3D / 3D Pro – ACUTE/OBTUSE ANGLE Place two intermediate posts 50 cm from the corner 18/05/2020 – Nylofor / Twilfix ® - Installation manual...
Page 16
2. Installation Installation of posts & panels PANELS ON TOP OF EACH OTHER SLOPES On slopes extra fixators must Connect the panels using 3 be placed brackets per panel - Measure the area accurately compared to the zero level - Do this in different places - The zero level can be determined by means of a laser or similar instrument - Determine all differences in height on...
Page 17
2. Installation Installation of posts & panels INSTALLATION WITH CONCRETE SLABS Use concrete slab supports for 60x60 posts (hard PVC) width 4cm – height 30cm 18/05/2020 – Nylofor / Twilfix - Installation manual ®...
2. Installation Installation of Nylofor City system ASSEMBLING THE PANEL – Glue the neoprene strips on the top of the horizontal wire of the panel. Divide 3 strips over the complete width of the panel – Slide the panel into the top rail –...
Page 19
2. Installation Installation of Nylofor City system INSTALLING THE PANELS – Fasten the top of the panels with a metal clamp – Fasten the other positions of the panels with the PA clamps – Repeat these steps to complete the installation –...
Page 20
2. Installation Installation of Nylofor City system INSTALLING CORNERS / SLOPES – In case of a corner, use a corner post with inserts on two adjacent sides. Fasten the top of the panel with left and right corner clamps – Only corners of 90°...