Closed System Fireplace Operation
Explains Element4's closed system fireplaces and their intake/exhaust operation.
Flue Gas Terminal Requirements
Highlights the necessity of meeting flue gas terminal requirements for proper fireplace function.
System Compatibility and Waste Material
Details CE quality mark requirements for drainage and compatible flue systems.
Power-Fan for Challenging Flues
Discusses the use of Power-Fans for flue configurations where natural draught is insufficient.
Flue Gas Discharge Rules
Determine Flue Gas Outlet Diameter
Specifies how to determine the correct flue gas outlet diameter for installation.
Maximum Vertical Flue Length Limits
Defines the maximum permitted vertical length for flue gas outlets based on diameter.
Calculate Total Horizontal Flue Length
Explains the process for calculating total horizontal flue length, including bends.
Impact of Bends on Flue Resistance
Details how flue bends contribute to resistance and affect total length calculations.
Interpreting Flue Calculation Results (X, V, R)
Explains the meaning of 'X', 'V', and 'R' codes in flue calculation tables.
Flue Calculation Example
Six Questions for Flue Configuration
Outlines the essential questions for assessing flue configuration feasibility for a fireplace.
Visualizing Flue Configuration Components
Illustrates flue components and their designations for calculation purposes.
Appliance Categories and Calculation Tables
Metric Category 1 (Ratio 1:4) Tables
Provides calculation tables for Metric Category 1 (1:4 ratio) for horizontal and vertical terminals.
Metric Category 3 (Ratio 1:2) Tables
Provides calculation tables for Metric Category 3 (1:2 ratio) for horizontal and vertical terminals.
Imperial Category 2 (Ratio 1:2.5) Tables
Provides calculation tables for Imperial Category 2 (1:2.5 ratio) for horizontal and vertical terminals.
Imperial Category 4 (Ratio 1:1) Tables
Provides calculation tables for Imperial Category 4 (1:1 ratio) for horizontal and vertical terminals.
Existing Chimney Installation Guidelines
CE Approval and Flexible Pipe Usage
Details CE approval (C91) and guidelines for using flexible pipes in existing chimneys.
Chimney Requirements for Flexible Pipes
Specifies minimum chimney cross-sections and conditions for flexible pipe installations.
Important Chimney Safety and Closure
Emphasizes closing the chimney top/bottom and checking for leaks for safe operation.