Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
IFM Electronic Manuals
Accessories
PN2094
Operating instructions manual
IFM Electronic PN2094 Operating Instructions Manual
Electronic pressure sensor
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
page
of
35
Go
/
35
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
Preliminary Note
1�1 Symbols Used
Safety Instructions
Functions and Features
3�1 Applications
Function
4�1 Operating Modes
4�2 Communication, Parameter Setting, Evaluation
4�3 Switching Function
4�4 Analogue Function
4�5 IO-Link
4�5�1 General Information
4�5�2 Functions Only Available Via IO-Link Communication
Installation
Electrical Connection
Operating and Display Elements
Menu
8�1 Menu Structure: Main Menu
8�2 Explanation of the Menu
8�2�1 Explanation of Menu Level 1
8�2�2 Explanation of Menu Level 2
Parameter Setting
9�1 Parameter Setting in General
9�2 Define Operating Mode (Optional)
9�3 Configure Display (Optional)
9�4 Set Output Signals
9�4�1 Set Output Functions
9�4�2 Define Switching Limits for the Hysteresis Function
9�4�3 Define Switching Limits for the Window Function
9�4�4 Scale Analogue Value
9�5 User Settings (Optional)
9�5�1 Set Delay Time for the Switching Outputs
9�5�2 Set Output Logic for the Switching Outputs
9�5�3 Set Damping for the Switching Signal
9�5�4 Set Damping for the Analogue Output
9�5�5 Zero-Point Calibration
9�5�6 Reset All Parameters to Factory Setting
9�5�7 Set Colour Change of the Display
9�5�8 Graphical Depiction of the Colour Change of the Display
9�6 Diagnostic Functions
9�6�1 Read Min/Max Values for the System Pressure
Operation
10�1 Read Set Parameters
10�2 Self-Diagnostics / Fault Indications
Technical Data
11�1 Setting Ranges
11�1�1 Setting Ranges in Operating Mode 2
11�1�2 Setting Ranges in Operating Mode 3
Factory Setting
Advertisement
Quick Links
1
4�1 Operating Modes
2
4�2 Communication, Parameter Setting, Evaluation
3
4�4 Analogue Function
4
9�1 Parameter Setting in General
Download this manual
Operating instructions
Electronic pressure sensor
UK
UK
PN2
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the PN2094 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for IFM Electronic PN2094
Accessories IFM Electronic PY2954 Operating Instruction
Combined pressure sensor (19 pages)
Accessories IFM Electronic PA32xx Series Installation Instructions Manual
Electronic pressure sensor (6 pages)
Accessories IFM Electronic PN5 series Operating Instructions Manual
Electronic pressure sensor (33 pages)
Accessories IFM Electronic PN7000 Operating Instructions Manual
Pn70 series pressure sensor (19 pages)
Accessories IFM Electronic Efectorsod PM2053 Operating Instructions Manual
Electronic pressure sensor, pm205 series (13 pages)
Accessories IFM Electronic PN72 Series Operating Instructions Manual
Electronic pressure sensor (25 pages)
Accessories IFM Electronic PY995 Series Operating Instructions Manual
Electronic pressure sensor (38 pages)
Accessories IFM Electronic PI7093 Operating Instructions Manual
Electronic pressure sensor (21 pages)
Accessories IFM Electronic PN50 Series Operating Instructions Manual
Pressure sensor (17 pages)
Accessories IFM Electronic PN5004 Operating Instructions Manual
Pressure sensor (17 pages)
Accessories IFM Electronic efectro 500 Operating Instructions Manual
Pressure sensor (17 pages)
Accessories IFM Electronic PN2 Series Operating Instructions Manual
Electronic pressure sensor (35 pages)
Accessories IFM Electronic PB7 Operating Instructions Manual
Electronic pressure sensor (23 pages)
Accessories IFM Electronic PI209 Series Operating Instructions Manual
Electronic pressure sensor (21 pages)
Accessories IFM Electronic Efectorsod PE70 Series Operating Instructions Manual
Pressure sensor (17 pages)
Accessories IFM Electronic LK1022 Operating Instructions Manual
Electronic level sensor lk10 series lk70 series (35 pages)
Summarization of Contents
Preliminary note
Symbols used
Explains symbols used throughout the document for clarity.
Safety instructions
General safety guidelines
Outlines critical safety precautions for device integration and operation.
Functions and features
Applications
Describes the intended use and applications of the electronic pressure sensor.
Function
Operating modes
Details the different operating modes available for the device.
Communication, parameter setting, evaluation
Covers communication protocols, parameter adjustment, and data evaluation methods.
Switching function
Explains how the sensor's outputs switch based on pressure limits.
Analogue function
Describes the sensor's analogue output signal configuration and behavior.
IO-Link
Introduces the IO-Link communication interface for advanced device integration.
General information
Provides an overview of the IO-Link interface requirements and capabilities.
Functions only available via IO-Link communication
Lists specific features accessible exclusively through IO-Link.
Installation
Installation procedure
Step-by-step guide for physically installing the pressure sensor.
Electrical connection
Wiring instructions
Details the electrical connections and wiring examples for the device.
Operating and display elements
Device interface overview
Explains the function of LEDs, buttons, and the display on the device.
Menu
Menu structure: main menu
Outlines the hierarchical structure of the device's menu system.
Explanation of the menu
Provides detailed descriptions for menu items and their functions.
Explanation of menu level 1
Explains parameters and settings found in the first level of the menu.
Explanation of menu level 2
Details parameters and settings within the second level of the menu.
Parameter setting
Parameter setting in general
Describes the general procedure for setting device parameters.
Define operating mode (optional)
Guides the user on selecting and configuring the device's operating mode.
Configure display (optional)
Explains how to customize the display unit and update rate.
Set output signals
Details how to configure the device's output signals and their behavior.
Set output functions
Defines the specific functions for the switching outputs (hysteresis, window).
Define switching limits for the hysteresis function
Sets the upper and lower limits for hysteresis switching functions.
Define switching limits for the window function
Sets the upper and lower limits for window switching functions.
Scale analogue value
Configures the scaling for the analogue output signal.
User settings (optional)
Covers optional user-configurable settings for enhanced functionality.
Set delay time for the switching outputs
Configures the switch-on and switch-off delay times for outputs.
Set output logic for the switching outputs
Sets the output logic (PNP/NPN) for the switching outputs.
Set damping for the switching signal
Adjusts the damping constant for switching signals and process data.
Set damping for the analogue output
Configures the damping for the analogue output signal.
Zero-point calibration
Guides the user through the process of zero-point calibration.
Reset all parameters to factory setting
Restores the device to its default factory parameter settings.
Set colour change of the display
Configures the display color based on output status or measured value.
Graphical depiction of the colour change of the display
Visual examples illustrating how display colors change with parameters.
Diagnostic functions
Read min/max values for the system pressure
Allows reading and clearing of minimum and maximum recorded pressure values.
Read overload processes
Accesses information about overload events and their thresholds.
Operation
Read set parameters
Instructions on how to view the currently configured parameters.
Self-diagnostics / fault indications
Explains how the device performs self-diagnostics and displays fault/warning messages.
Technical data
Setting ranges
Provides detailed tables of setting ranges for various product models.
Setting ranges in operating mode 2
Lists specific setting ranges applicable to operating mode 2.
Setting ranges in operating mode 3
Lists specific setting ranges applicable to operating mode 3.
Factory setting
Default parameter values
Displays the default factory settings for all configurable parameters.
Table of Contents
Save PDF
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the PN2094 and is the answer not in the manual?
Questions and answers