Sartorius Gem Series Service Manual

Sartorius Gem Series Service Manual

Electronic analytical and precision balances and precious metal scales

Advertisement

Service Manual
Sartorius Talent | Gem, Gold
TE Models
Electronic Analytical and Precision
Balances and Precious Metal Scales
Including Service Specification Sheets
WTE5001-e03101

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Gem Series and is the answer not in the manual?

Questions and answers

Summarization of Contents

Generals Information
Important Information
Critical safety and procedural guidelines for servicing.
General Notes and Service Guide
Service Guide
Step-by-step guide for performing essential service tasks.
BPI Mode and Write-Protect Management
Instructions for enabling/disabling BPI mode and write protection.
Write-Protect Reset Procedure
Procedure to reset write protection settings.
Main PCB Replacement
Steps for replacing the main printed circuit board.
Weighing Systems Identification
Identifies the types of weighing systems used.
Housing Opening Procedure
Instructions for safely opening the balance/scale housing.
Service Software Usage
Details on the required service software and its usage.
Off-Center Load Adjustment
Method for adjusting the off-center load error.
Span Adjustment Procedure
Procedure for adjusting the span of the balance.
Models with Special Weighing Systems
Model 1 Specifications
Specifications and weighing system for Model 1.
Model 2 Specifications
Specifications and weighing system for Model 2.
Model 3 Specifications
Specifications and weighing system for Model 3.
Model 4 Specifications
Specifications and weighing system for Model 4.
Auxiliary Service Tools and Weights
Accompanying Literature
References to related documentation and manuals.
Required Weights for Service
Details on required weight sets for calibration and testing.
Handling and Operating TE Balances/Scales
Function of the Keys
Explanation of the purpose and function of each key on the balance.
Displaying Hardware and Software Versions
Procedure to view the balance's hardware and software versions.
Operating Menu Access Switch
Location and usage of the menu access switch for configuration.
Balance/Scale Operating Menu Navigation
Instructions for accessing and navigating the operating menu.
Menu Code Settings (Version 19.41)
Configuration options and settings within the menu system.
Activating the BPI Mode
Steps to enable BPI mode for service software communication.
Balances/Scales with Strain Gauge Systems
Checking the Overload Stop
Procedure for checking the overload stop function.
Table of Weights for Overload Stop
List of test weights required for overload stop checks.
Zero-point Offset Value Adjustment
Understanding and adjusting the zero-point offset value.
Table of Adjustment Resistors
Resistor values for zero-point offset adjustment.
Repeatability (Standard Deviation) Check
Procedure for checking and calculating repeatability.
Off-center Error Check and Adjustment
Procedure for checking and adjusting off-center loading errors.
Span Adjustment Procedure
Procedure for adjusting the span of the balance.
Linearity Check and Adjustment
Procedure for checking and adjusting linearity.
Balances/Scales with Double Lever Systems
Checking and Adjustment Sequence
Steps for checking and adjusting double lever systems.
Overload Stops in Double Lever Systems
Information regarding overload stops in double lever systems.
Repeatability Check for Double Lever Systems
Procedure for checking repeatability in double lever systems.
Off-center Error in Double Lever Systems
Guidance on checking off-center loading errors.
Off-Center Error Adjustment (Double Lever)
Steps to adjust the off-center loading error.
3-point Measurement for Off-Center Error
Method for determining off-center loading error using 3 points.
System Position for Off-Center Adjustment
Diagrams showing filing positions for off-center error adjustment.
Span Adjustment for Double Lever Systems
Procedure for adjusting the span of the balance.
Linearity Check and Adjustment (Double Lever)
Procedure for checking and adjusting linearity.
Opening and Closing the Balance/Scale
Opening the Balance/Scale
Steps to open the balance/scale for service access.
Closing the Balance/Scale
Steps to reassemble the balance/scale after service.
Error Codes and Solutions
Error Codes H, L
Error codes H and L related to load and placement.
Error Codes E01, E02, E10, E11
Error codes E01, E02, E10, E11 and their resolutions.
Error Code E22
Error code E22 related to weight or sample.
Error Code E30
Error code E30 related to BPI mode.
Error Codes E50, E53, E54, E55
Error codes E50, E53, E54, E55 related to converters and sensors.
Service Specification and Tolerances
TE214S, TE124S, TE64 Specifications
Service specifications for TE214S, TE124S, and TE64 models.
TE313S, GD103, GD603 Specifications
Service specs for TE313S, GD103, and GD603 models.
TE153S, GD252 Specifications
Service specs for TE153S, TE153S-DS, and GD252 models.
TE612, TE412, GE412 Specifications
Service specs for TE612, TE412, and GE412 models.
TE212, GE212, GE812 Specifications
Service specs for TE212, GE212, and GE812 models.
TE1502S, GE2102, GE1302, TE3102S Specifications
Service specs for TE1502S, GE2102, GE1302, TE3102S models.
TE6101, TE4101, GE4101, GE7101 Specifications
Service specs for TE6101, TE4101, GE4101, GE7101 models.
TE2101, TE601, GE811 Specifications
Service specs for TE2101, TE601, GE811 models.
TE12000, TE6100, TE4100 Specifications
Service specs for TE12000, TE6100, TE4100 models.

Table of Contents

Save PDF