Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
ClimateMaster Manuals
Heat Pump
TCH120
Installation operation & maintenance
ClimateMaster TCH120 Installation Operation & Maintenance
Compact belt drive. 60hz - hfc-410a
Hide thumbs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
page
of
80
Go
/
80
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Table of Contents
Model Nomenclature
General Information
TCH Physical Data (Includes Unit W/Wse)
TCV Physical Data (Includes Unit W/Wse)
Horizontal Installation
TCH Field Conversion of Air Discharge
Vertical Installation
TCV Field Conversion of Air Discharge
TCV072-240 Field Conversion of Air Discharge
TCV300 Field Conversion of Air Discharge
TCV Field Conversion of Control Box
TCV Field Conversion of Water Connections
Vertical Condensate Installation
Piping Installation
Water-Loop Heat Pump Applications
Ground-Loop Heat Pump Applications
Ground-Water Heat Pump Applications
Water Quality Standards
Electrical - Line Voltage
Electrical - Power Wiring
Electrical - Power & Low Voltage Wiring
Electrical - Thermostat Wiring
Typical Wiring Diagram - TCH/V Units with CXM
CXM Controls
DXM Controls
Safety Features
CXM and DXM Controls
Blower Adjustment
Tensioning V-Belt Drives
Blower Sheave Information
TCH/V 072 Blower Performance
TCH/V 096 Blower Performance
TCH/V 120 Blower Performance
Blower Performance Data - TCV160 Standard Unit
Blower Performance Data - TCV192 Standard Unit
Blower Performance Data - TCV240 Standard Unit
Blower Performance Data - TCV300 Standard Unit
Unit Starting and Operating Conditions
Piping System Cleaning and Flushing
Unit Starting and Operating Conditions
Unit Start-Up Procedure
Unit Operating Conditions
Start-Up Log Sheet
Preventive Maintenance
Circuit Diagram with Safety Devices
Functional Troubleshooting
Performance Troubleshooting
Warranty (U.S. & Canada)
Revision History
Advertisement
Quick Links
1
Model Nomenclature
2
General Information
3
Tch Physical Data (Includes Unit W/Wse)
4
Functional Troubleshooting
Download this manual
Tranquility
Belt Drive (TCH/V) Series
Models TCH072 - 120
TCV072 - 300
60Hz - HFC-410A
Installation, Operation
& Maintenance
97B0084N01
Revised: July 25, 2017
Compact
®
Table of Contents
Model Nomenclature
General Information
TCH Physical Data
(includes unit w/WSE)
TCV Physical Data
(includes unit w/WSE)
Horizontal Installation
TCH Field Conversion of Air Discharge
Vertical Installation
TCV Field Conversion of Air Discharge
TCV072-240 Field Conversion of Air Discharge
TCV300 Field Conversion of Air Discharge
TCV Field Conversion of Control Box
TCV Field Conversion of Water Connections
Vertical Condensate Installation
Piping Installation
Water-Loop Heat Pump Applications
Ground-Loop Heat Pump Applications
Ground-Water Heat Pump Applications
Water Quality Standards
Electrical - Line Voltage
Electrical - Power Wiring
Electrical - Power & Low Voltage Wiring
Electrical - Thermostat Wiring
Typical Wiring Diagram - TCH/V Units with CXM
CXM Controls
DXM Controls
Safety Features
CXM and DXM Controls
Blower Adjustment
Tensioning V-Belt Drives
Blower Sheave Information
TCH/V 072 Blower Performance
TCH/V 096 Blower Performance
TCH/V 120 Blower Performance
Blower Performance Data - TCV160 Standard Unit
Blower Performance Data - TCV192 Standard Unit
Blower Performance Data - TCV240 Standard Unit
Blower Performance Data - TCV240 Standard Unit
Blower Performance Data - TCV300 Standard Unit
Unit Starting and Operating Conditions
Piping System Cleaning and Flushing
Unit Starting and Operating Conditions
Unit Start-Up Procedure
Unit Operating Conditions
Start-Up Log Sheet
Preventive Maintenance
Circuit Diagram with Safety Devices
Functional Troubleshooting
Performance Troubleshooting
Warranty (U.S. & Canada)
Revision History
3
4
6
9
16
18
21
22
23
26
29
30
31
32
33
34
36
38
39
41
42
44
45
49
50
52
53
54
55
56
57
58
60
62
63
64
65
66
67
68
69
70
72
73
74
75
76
77
79
80
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Troubleshooting
Functional Troubleshooting
76
Performance Troubleshooting
77
Need help?
Do you have a question about the TCH120 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for ClimateMaster TCH120
Heat Pump ClimateMaster Tranquility 16 Compact Series Installation, Operation & Maintenance Manual
Compact (tc) series 60 hz - hfc-410a water-source heat pump systems (52 pages)
Heat Pump ClimateMaster Tranquility 16 Compact Series Installation Operation & Maintenance
Water-source heat pumps (84 pages)
Heat Pump ClimateMaster Tranquility TCH Series Installation Operation & Maintenance
Compact belt drive. 60hz - hfc-410a (80 pages)
Heat Pump ClimateMaster TCV096 Installation Operation & Maintenance
Compact belt drive. 60hz - hfc-410a (80 pages)
Heat Pump ClimateMaster TCV120 Installation Operation & Maintenance
Compact belt drive. 60hz - hfc-410a (80 pages)
Heat Pump ClimateMaster TCH096 Installation Operation & Maintenance
Compact belt drive. 60hz - hfc-410a (80 pages)
Heat Pump ClimateMaster Tranquility 16 Series Installation Operation & Maintenance
Commercial horizontal & vertical packaged water-source heat pumps (52 pages)
Heat Pump ClimateMaster Tranquility Digital Troubleshooting Manual
Residential packaged digital geothermal heat pumps (62 pages)
Heat Pump ClimateMaster Tranquility TRH 006 Installation Operation & Maintenance
(72 pages)
Heat Pump ClimateMaster Tranquility 20 Series Installation Operation & Maintenance
Water-source heat pumps (68 pages)
Heat Pump ClimateMaster Tranquility 20 Series Installation, Operation & Maintenance Instructions Manual
Residential horizontal & vertical packaged geothermal heat pumps (68 pages)
Heat Pump ClimateMaster Tranquility TY Series Installation, Operation, Maintenance Manual
Water -source heat pumps (56 pages)
Heat Pump ClimateMaster Tranquility 30 Digital TE Series Installation, Operation & Maintenance Instructions Manual
Residential horizontal, vertical & downflow packaged geothermal heat pumps (68 pages)
Heat Pump ClimateMaster TRANQUILITY LARGE Series Installation Operation & Maintenance
Commercial vertical packaged heat pump-50hz (68 pages)
Heat Pump ClimateMaster TRC09 Installation Operation & Maintenance
Commercial console water-source heat pumps 50hz & 60hz tranquility console (trc) series (44 pages)
Heat Pump ClimateMaster Tranquility TTD026 Series Installation Operation & Maintenance
60 hz - hfc-410a (56 pages)
Summarization of Contents
Model Nomenclature
Model Type and Configuration
Defines model type (TCH/TCV) and installation configuration.
Unit Size and Voltage Options
Lists available unit sizes and voltage selections.
Controls and Drive Options
Details control types (CXM/DXM) and blower drive packages.
General Information
Safety Warnings and Precautions
Covers DANGER, WARNING, CAUTION, and NOTICE statements for safe operation.
Inspection, Storage, and Unit Protection
Guidelines for receiving, storing, and protecting units on site.
Pre-Installation Site Requirements
Requirements for unit location and service access.
TCH Physical Data
TCH Model Specifications
Lists technical data like compressor quantity, charge, motor specs.
TCH Unit Dimensions and Filters
Details air coil dimensions, face area, and filter sizes.
TCH Corner Weights
Weight distribution for TCH models.
TCH Unit with WSE Option Data
Physical specifications for TCH units with Water Side Economizer.
TCH072-120 Dimensional Data
TCV Physical Data
TCV Model Specifications
Lists technical data like compressor quantity, charge, motor specs.
TCV Unit Dimensions and Filters
Details air coil dimensions, face area, and filter sizes.
TCV Corner Weights
Weight distribution for TCV models.
TCV Unit with WSE Option Data
Physical specifications for TCV units with Water Side Economizer.
TCV072-120 Dimensional Data
TCV160-240 Dimensional Data
TCV300 Dimensional Data
Horizontal Installation
Horizontal Unit Location and Access
Guidance on selecting indoor locations for horizontal units.
Mounting Horizontal Units
Instructions and illustrations for hanging horizontal units.
Horizontal Units Condensate Piping
Duct System Installation Guidelines
TCH Field Conversion of Air Discharge
Side to Back Discharge Conversion
Step-by-step guide to convert air discharge.
Vertical Installation
Vertical Location and Access
Guidance on unit placement and service access.
Duct System Design & Installation Guidelines
Recommendations for ductwork for vertical units.
TCV Field Conversion of Air Discharge
TCV Field Conversion of Control Box
TCV Field Conversion of Water Connections
Vertical Condensate Installation
Piping Installation
Installation of Supply and Return Piping
Guidelines for connecting water lines and hoses.
Water-Loop Heat Pump Applications
Commercial Water Loop Applications
Details for connecting units to commercial loops.
Low Water Temperature Cutout Setting - CXM Control
Setting for low temp protection with CXM controls.
Ground-Loop Heat Pump Applications
Pre-Installation and Piping
Site preparation and loop piping guidelines.
Ground-Water Heat Pump Applications
Open Loop - Ground Water Systems
Guidelines for open loop configurations.
Expansion Tank and Pump
Sizing and installation of expansion tanks and pumps.
Water Control Valve
Placement and selection of water control valves.
Water Quality Standards
Electrical - Line Voltage
General Line Voltage Wiring
Basic principles for connecting line voltage.
Electrical Data Tables
Specifications for voltage, amps, FLA, and fuses.
Electrical - Power & Low Voltage Wiring
Thermostat Connections
Wiring instructions for thermostats to CXM/DXM.
Low Water Temperature Cutout Selection
Configuring low temp limits for water coils.
Electrical - Thermostat Wiring
Thermostat Installation
Guidelines for thermostat placement and wiring.
Typical Wiring Diagram - TCH/V Units with CXM
Typical Wiring Diagram - TCH/V Units with MPC
Typical Wiring Diagram - TCH/V Units with DXM
Typical Wiring Diagram - TCH/V Units with LON
CXM Controls
Field Selectable Inputs
Options for testing and diagnostics.
Field Configuration Options
DIP switch and jumper settings for configuration.
DXM Controls
Field Selectable Inputs
Options for testing and diagnostics.
Field Configuration Options
DIP switch and jumper settings for configuration.
Safety Features
CXM/DXM Control Safety Features
Details on safety protections like anti-short cycle, lockout.
CXM and DXM Controls Start-up Operation
Blower Adjustment
Sheave Adjustment
How to adjust the fan sheave for airflow.
Belt Tensioning Procedure
Steps to properly tension the blower belt.
Tensioning V-Belt Drives
Tension Measurement Procedure
Method to measure and set belt tension accurately.
Blower Sheave Information
TCH/V 072 Blower Performance
TCH/V 096 Blower Performance
TCH/V 120 Blower Performance
Blower Performance Data – TCV160 Standard Unit
Blower Performance Data – TCV192 Standard Unit
Blower Performance Data – TCV240 Standard Unit
Blower Performance Data – TCV300 Standard Unit
Unit Starting and Operating Conditions
Operating Limits
Environmental and operational constraints for the unit.
Piping System Cleaning and Flushing
Unit Starting and Operating Conditions
BEFORE POWERING SYSTEM Checks
Essential checks before energizing the system.
Unit Start-Up Procedure
Initial Start-Up Steps
Step-by-step guide for initial system operation.
UNIT OPERATING CONDITIONS
Unit Operating Conditions
TCH/V072-120 Series Operating Pressures/Temperatures
Typical operating pressures and temperatures for specific models.
TCV160-300 Series Operating Pressures/Temperatures
Typical operating pressures and temperatures for specific models.
Start-Up Log Sheet
Preventive Maintenance
Water Coil Maintenance
Procedures for cleaning heat exchanger coils.
Filters and Condensate Drain Maintenance
Maintaining filters and drain pans for optimal performance.
Compressor and Fan Motor Maintenance
Checks and maintenance for motors.
Circuit Diagram with Safety Devices
Functional Troubleshooting
Fault Diagnosis and Solutions
Table listing common faults, causes, and solutions.
Performance Troubleshooting
Functional Troubleshooting - I-P Units
Warranty (U.S. & Canada)
Revision History
Table of Contents
Save PDF
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the TCH120 and is the answer not in the manual?
Questions and answers