If USB is selected, a USB flash drive must be installed to create the text file of the
indicator configuration.

6.4.8 Archive

ArchiVE
The indicator has memory capacity to store approximately 5,000 transactions.
The Archive report uses a rolling memory configuration (FIFO) so the oldest
transaction will be written over first when all the memory slots are filled.
ZM400 Series Indicators Service Manual
Print
Use this to print the indicator configuration information. You
pick the port to use for printing in the following steps. See the
extensive list in Chapter
Choices are Port 1 , Port 2 and uSb (text file).
rESEt
Under this item you can choose to reset the APP.cnFg (reset
configuration settings back to how the application had it set
when it was last downloaded), conFig (factory default
settings) and cAL (factory default calibration) memory or
choose ALL to reset both config and cal factory defaults at
once.
Archive
Enable
Print
Off
On
Port 1
This stands for electronic archive. In other regions it is known as an alibi
memory or tally roll. These will be transmitted via configured
communications ports. These reports can be used to confirm a weighment
if it is ever in dispute. Only records that are qualified as a LEGAL record,
per site motion criteria, are considered as entries to this log.
EnAbLE
Choose on to enable a PC query. If enabled, a Print menu
item appears to the right of EnAbLE .
Print
You can choose to print the archive from Port 1, 2 or to USB.
(USB device must be installed)
9 - Printed reports (page 104)
Appears if
Archive enabled
Port 2
USB
6.4