ZM505
Indicator
User Instructions
AWT35-501338
Issue AC

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZM505 and is the answer not in the manual?

Questions and answers

Summary of Contents for Avery Weigh-Tronix ZM505

  • Page 1 ZM505 Indicator User Instructions AWT35-501338 Issue AC...
  • Page 2 This publication was correct at the time of going to print, however Avery Weigh-Tronix reserves the right to alter without notice the specification, design, price or conditions of supply of any product or service at any time.
  • Page 3: Table Of Contents

    Chapter 2 Introduction ..........................12 Front panel ........................13 Display ........................14 Powering up a ZM505 series indicator ................15 Using the alphanumeric keypad ..................15 Entering negative numbers or decimal point ..............15 Chapter 3 Operator Instructions ......................16 Power Up .........................
  • Page 4 Print ........................... 30 Chapter 5 Error messages ........................31 Chapter 6 Supervisor menu ........................32 Printed Preset Tare report example ................. 33 ZM401/405 Indicator User Instructions...
  • Page 5: Chapter 1 General Information And Warnings

    NOTE: This is a Note symbol. Notes give additional and important information, hints and tips that help you to use your product. 1.2 Installation NO USER SERVICEABLE PARTS. REFER TO QUALIFIED SERVICE PERSONNEL FOR SERVICE. ZM505 Indicator User Instructions...
  • Page 6: Safe Handling Of Equipment With Batteries

    IMPORTANT: This equipment must be routinely checked for proper operation and calibration. Application and usage will determine the frequency of calibration required for safe operation. Always isolate the indicator from the power supply before starting any routine maintenance to avoid the possibility of electric shock. ZM505 Indicator User Instructions...
  • Page 7: Cleaning The Machine

    To avoid the risk of RSI (Repetitive Strain Injury), place the machine on a surface which is ergonomically satisfactory to the user. Take frequent breaks during prolonged usage. 1.6 Sharp objects Do not use sharp objects such as screwdrivers or long fingernails to operate the keys. ZM505 Indicator User Instructions...
  • Page 8: Fcc And Emc Declarations Of Compliance

    Classe A prescrites dans le Règlement sur le brouillage radioélectrique edicté par le ministère des Communications du Canada. European Countries WARNING: This is a Class A product. In a domestic environment, this product may cause radio interference in which the user may be required to take adequate measures. ZM505 Indicator User Instructions...
  • Page 9: Declarations Of Conformity

    Declarations of Conformity 1.8 Declarations of Conformity ZM505 Indicator User Instructions...
  • Page 10 General information and warnings ZM505 Indicator User Instructions...
  • Page 11 Declarations of Conformity ZM505 Indicator User Instructions...
  • Page 12: Chapter 2 Introduction

    The ZM505 indicator will support up to four scales with a maximum total of 24 - 350 ohm load cells. The standard indicator can connect to four scales, three of which can be digital.
  • Page 13: Front Panel

    Never press a key with anything but your finger. Damage to the overlay may result if sharp or rough objects are used. The normal function of the keys on the front panel of the ZM505 are listed below. Press the TARE key for pushbutton, key entry or preset Tare functions.
  • Page 14: Display

    Ethernet preset activity tare Figure 2.2 Annunciators These annunciators will light during operation to inform the user of the weighing mode, active unit of measure, etc. ZM505 Indicator User Instructions...
  • Page 15: Powering Up A Zm505 Series Indicator

    (-) negative sign. Enter the rest of the digits normally. To enter a decimal point (or comma), on a ZM505 use the decimal point key. To enter a value less than 1 requires the entry of the leading 0 before a decimal point is allowed.
  • Page 16: Chapter 3 Operator Instructions

    Operator Instructions Operator Instructions The ZM505 indicator comes standard with a basic accumulation weighing application and 10 Preset Tares. Custom applications can be written in LUA programming language or by installing Macro programs.. SELECT key default function: You can view the gross, net, tare, gross total, net total, tare total and transaction total display values or other configured scale parameters by repeatedly pressing SELECT.
  • Page 17 TARE for 3 seconds the display will show cLEArEd and the Tare weight is cleared. If gross weight is not at 0, press the ZERO key; then press the TARE key to clear the tare value. ZM505 Indicator User Instructions...
  • Page 18 When the item is removed from the scale the Tare is cleared automatically if Auto Tare Clear is enabled. To remove the tare weight manually, select a preset tare that has a value of 0 for the tare or press and hold TARE for three seconds. ZM505 Indicator User Instructions...
  • Page 19: Using The Accumulation Function

    1077 lb Tare Total 50 lb Net Total 1027 lb CHAN key (F1) Press this key and the alphanumeric entry screen appears. Key in the Channel number and press the ENTER key. The main screen appears. ZM505 Indicator User Instructions...
  • Page 20: Performing Accumulation Weighments

    If enabled, press and hold the PRINT key to transmit current active total channel data out serial port #1. This will also clear the current active channel data if the clear feature is enabled under the Supervisor’s Menu. ZM505 Indicator User Instructions...
  • Page 21: Chapter 4 Menus

    Password protected menus are available to configure the indicator and/or view information. 4.1 Accessing the menus Follow these steps to access the menus in the ZM505 indicator. With the indicator powered up and in normal operating mode, press and hold SETUP …...
  • Page 22: Exiting The Menus

    User About Audit page page page Figure 4.1 USER level (password 111) menus To access the USER level, from normal weighing mode, press and hold the F1 key. Enter password 111 and press the ZERO key. ZM505 Indicator User Instructions...
  • Page 23: User Menu

    24 hr. m- x s- x The Time and Date can be used in print formats. Use this to enter values for the time. h- x, = Hour m- x = Minute s- x = Seconds ZM505 Indicator User Instructions...
  • Page 24: Date

    This is the status of the physical seal jumper inside the View Seal indicator. If the unit is sealed, no changes can be made to Status the configuration of the indicator. To exit the menu, see Exiting the menus on page 22. ZM505 Indicator User Instructions...
  • Page 25: About Menu

    Use this menu to display information about the various items shown in Figure 4.3. Each is explained below: Definitions: Bootloader Software that makes the electronics run. Firmware Embedded system software that creates core functions of the product. Specific software that controls the behaviour for a given installation. ZM505 Indicator User Instructions...
  • Page 26: Boot (Bootloader)

    Use this to view the Serial Number of the indicator. The Serial number is displayed in two parts. Press RIGHT arrow key or LEFT arrow key to toggle the display between the (View SN) xxxx xxxxx first and second parts of the serial number. ZM505 Indicator User Instructions...
  • Page 27: Enet

    Use this to view the description and version of an installed option card. Option Bus 1 or 2 There are 2 Busses in the ZM505. Bus 1 Bus 2 Card 1 or 2 There can be 2 Cards on each bus in the ZM505.
  • Page 28: Download

    View the serial number of the cell that is connected. cAL.SEr View the serial number of the cell that WAS connected at the time of calibration. To exit the menu, see Exiting the menus on page 22. ZM505 Indicator User Instructions...
  • Page 29: Audit Menu

    Use this to view these items: Counter conFig View how many times the indicator has been Config Calib configured. Displays Displays cALib View how many times the number of number of indicator has been configurations calibrations calibrated. ZM505 Indicator User Instructions...
  • Page 30: Print

    Printing to USB requires that a USB flash drive is connected to the indicator host USB. Printing to USB will create a folder on the flash drive and a comma separated file with the data. To exit the menu, see Exiting the menus on page 22. ZM505 Indicator User Instructions...
  • Page 31: Chapter 5 Error Messages

    Indicator did not reach a stable zero weight within time window set for automated weighing process. BSQ Cal Error / Indicator and BSQ have not been calibrated together. #1 denotes the scale number. Communication error between indicator and BSQ. ZM505 Indicator User Instructions...
  • Page 32: Chapter 6 Supervisor Menu

    The tare portion of the menu appears only if Preset Tare is enabled. Refer to the Service manual. To access the Supervisor menu enter the Supervisor password, 1793. The ZM505 has a Preset Tare register memory which can store 10 tares.
  • Page 33: Printed Preset Tare Report Example

    2524.000000 442.000000 rESEt This clears the entire 200-channel database. This completes the Supervisor menu. To return to normal mode repeatedly press the TARE key to exit. 6.1 Printed Preset Tare report example Tare Index Preset Tare ZM505 Indicator User Instructions...
  • Page 34 Supervisor menu ZM505 Indicator User Instructions...
  • Page 36 Avery Weigh-Tronix USA 1000 Armstrong Dr. Fairmont MN 56031 USA Tel:507-238-4461 Fax:507-238-4195 Email: usinfo@awtxglobal.com www.averyweigh-tronix.com Avery Weigh-Tronix UK Foundry Lane, Smethwick, West Midlands, England B66 2LP Tel:+44 (0) 8453 66 77 88 Fax:+44 (0)121 224 8183 Email: info@awtxglobal.com www.averyweigh-tronix.com...