1.3ghz & 2.7ghz rf spectrum analyzers; thurlby thandar instruments
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
page
of
47
Go
/
47
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Table of Contents
1 Supplied Items
2 Using this Manual & Meaning of Terms
3 Initial Operations
Charging the Batteries
Initialising the Palm T|X
Software Provided by Palm on CD
Linking to a Personal Computer
4 First Use of the Spectrum Analyzer
Quick Start Guide
Detailed Operating Guide
5 Product Description and Capabilities
6 Specification
Frequency Measurement
Amplitude Measurement
Sweep
Signal Input
Demodulation (Zero Span Mode)
Display
Memory Storage
Connectors
Power Sources
Mechanical
Environmental and Safety
7 Declaration of Conformity
8 Emc
9 Safety
10 Connections
RF Signal Input
DC Power Input
Demodulated Audio Output
USB 'Through' Connector
11 Stylus
12 Memory Card
Removing and Inserting the Card
Using an Alternative Card
Card Storage Capacity
13 Removing and Re-Fitting the Palm T|X
14 Re-Initialising the Palm T|X
Procedure for Re-Initialising
Technical Note about the off State
15 Language Choice for the Palm T|X
16 Turning on and Turning off
Palm T|X On/Off
PSA1301/2701 On/Off Control
Operation Delay after Turning on
17 Battery and AC Power
Battery Operation
AC Power Operation
Extended Periods Without Use
18 Using the Psanalyzer Application
Initial Conditions
Selecting and Leaving the Application
Touch Screen or Hard Key Operation
The Psanalyzer Screen
Operation and Navigation
Turning off / Power Saving
19 The Psanalyzer Menu System
Home Menu
Menus Summary
Mode Menu
Centre Menu
Step Value Sub Menu
Span Menu
Start Frequency Menu
Stop Frequency Menu
AM/FM Menu
Level Menu
Markers Menu
Sweep Menu
Traces Menu
Stores Menu
System Menu
Exit Menu
Quick Menu
20 Psanalyzer Operating Techniques
Menu Navigation
Frequency Setting
Performing Sweeps
Level Measurements
The PRESET Key
Using Markers
Reference Trace
Store, Recall and Copy
Creating and Displaying Limit Lines
Screen Resolution and Trace Thickness
Changing the Palm Input Area Type
Adjusting the Display Brightness
21 Help Screens
22 Functions Outside of Psanalyzer
Viewing a Stored Screen Image
Printing a Stored Screen Image (Using a Printer Connected to a PC)
Transferring Psanalyzer Files to a Personal Computer
23 Psanalyzer Files and Defaults
Factory Default Settings for Psanalyzer
File Locations for Psanalyzer Data Files
File Structures for Psanalyzer Data Files
24 Maintenance, Calibration and Repair
Screen Protection
Cleaning
Maintaining Battery Condition
Calibration
25 Trouble Shooting
Correcting Unexpected Conditions in Psanalyzer
Resetting the Palm T|X
Reinstalling or Updating the Psanalyzer Application
Optional Accessories
Creating a Shortcut to Psanalyzer
Advertisement
Quick Links
1
Charging the Batteries
2
Quick Start Guide
3
Frequency Measurement
4
Calibration
Download this manual
THURLBY THANDAR INSTRUMENTS
PSA-T Series PSA1301T & PSA2701T
INSTRUCTION MANUAL
1.3GHz & 2.7GHz RF Spectrum Analyzers
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the PSA1301T and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for TTI PSA1301T
Measuring Instruments TTI PSA2702 Instruction Manual
2.7ghz & 1.3ghz spectrum analyzers (61 pages)
Measuring Instruments TTI PSA1302 Instruction Manual
2.7ghz & 1.3ghz spectrum analyzers (61 pages)
Measuring Instruments TTI PSA2701T Instruction Manual
1.3ghz & 2.7ghz rf spectrum analyzers; thurlby thandar instruments (47 pages)
Measuring Instruments TTI PFM3000 Instruction Manual
Portable frequency meter (21 pages)
Measuring Instruments TTI 1604 Service Manual
Digital multimeter (22 pages)
Measuring Instruments TTI LD300 Service Manual
300w dc electronic load (51 pages)
Measuring Instruments TTI TTIDM1000VAR Operating Instructions Manual
Auto-ranging multimeter (24 pages)
Measuring Instruments TTI PROFESSIONALS TTICM1000V Operating Instructions Manual
600a ac clamp meter, auto ranging (20 pages)
Measuring Instruments TTI PROFESSIONALS TTICM600V Operating Instructions Manual
400a ac/dc clamp meter auto ranging (20 pages)
Measuring Instruments TTI FTE-7000A User Manual
Optical time domain reflectometer (50 pages)
Measuring Instruments TTI FTE-7000A-DWDM User Manual
Optical time domain reflectometer (59 pages)
Measuring Instruments TTI FTE6100 User Manual
Tunable laser source (26 pages)
Summarization of Contents
Supplied Items
Understanding the Manual
Manual Cross References
Explains how cross-references are presented in the manual, including hyperlink usage.
Terminology Definitions
Defines abbreviations like TTi and terms like 'handheld computer' for clarity.
Product Identification
Clarifies terminology for the spectrum analyzer unit and the complete system.
Initial Operations and Setup
Charging the Batteries
Instructions for charging the unit's batteries using the supplied mains adaptor for 4 hours.
Palm T|X Initialization
Procedure for re-initializing the Palm T|X after a full battery discharge.
Palm Software and PC Link
Guidance on Palm software installation and connecting the unit to a PC.
First Use Guide
Quick Start Guide
Step-by-step instructions for quickly setting up and making initial measurements.
Detailed Operating Guide
Recommends reading key sections for comprehensive understanding of operation.
Product Overview
PSA-T Series Summary
Overview of portability, battery life, frequency range, and resolution bandwidth.
Key Features and Capabilities
Details on amplitude range, sweep modes, markers, trace storage, and auto-sleep.
Instrument Specifications
Frequency Measurement Specs
Covers frequency span, range, setting modes, resolution, accuracy, and phase noise.
Amplitude Measurement Specs
Details amplitude range, units, reference level, accuracy, flatness, linearity, and noise floor.
Sweep and Signal Input Specs
Information on sweep methods, time, modes, signal input connector, and VSWR.
Demodulation and Display Specs
Details demodulation modes, audio output, display type, trace area, and resolution.
Memory and Connector Specs
Covers memory storage types and connector types for the instrument.
Power Sources and Mechanical Specs
Details AC/battery power, auto-sleep, size, weight, and tilt stand.
Environmental and Safety Compliance
Specifies operating conditions, storage, and compliance with safety standards.
Declaration of Conformity
EC Declaration
Statement of compliance with EMC and Low Voltage Directives.
Electromagnetic Compatibility (EMC)
Spectrum Analyzer EMC
Details EMC standards compliance for emissions and immunity.
Adaptor/Charger EMC
Specifies EMC compliance for the AC adaptor/charger.
Safety Precautions
Spectrum Analyzer Safety
Covers safety class, design requirements, operating warnings, and electrical safety.
Adaptor/Charger Safety
Provides safety information for the AC adaptor/charger.
Instrument Connections
RF Signal Input
Details the RF input connector, impedance, and maximum allowable signal levels.
DC Power Input
Explains DC power connection, usage of TTi adaptor, and charging indicators.
Audio Output and USB
Describes the audio output jack and the USB connector for Palm Desktop.
Stylus and Memory Card Management
Stylus Usage
Information on using the provided stylus with the Palm T|X.
Memory Card Handling
Instructions for removing, inserting, and using alternative memory cards.
Card Storage Capacity
Details the size of memory cards and the typical file sizes for PSAnalyzer data.
Palm T|X Removal and Re-fitting
Removing the Palm T|X
Steps to detach the Palm T|X handheld computer from the spectrum analyzer.
Re-fitting the Palm T|X
Steps to reattach the Palm T|X handheld computer to the spectrum analyzer.
Preventing Unauthorized Removal
Method for securing the top cover to prevent unauthorized removal of the Palm T|X.
Palm T|X Re-initialization and Language
Re-initializing the Palm T|X
Procedure for re-initializing the Palm T|X after battery discharge.
Palm T|X OFF State Technical Note
Explains the Palm T|X's low power 'off' (sleep) state and its memory retention.
Language Settings
Information on changing the Palm T|X operating language.
Powering On and Off
Palm T|X Power Control
Methods for turning the Palm T|X on and off, including sleep mode.
Analyzer Power Control
How the spectrum analyzer unit's power is controlled via the Palm T|X.
Power-On Delay
Describes the delay and potential issues during the analyzer's power-on sequence.
Battery and AC Power Management
Battery Operation Details
Covers battery types, life, recharge times, and indicators for both units.
AC Power Operation
Information on using the AC adaptor as the permanent power source.
Extended Non-Use Battery Care
Advice on maintaining battery charge during prolonged periods of inactivity.
Using the PSAnalyzer Application
Initial Conditions for Use
Pre-operation checks including signal connection and disabling wireless functions.
Launching and Exiting
Steps to start the PSAnalyzer application and return to the Palm's home menu.
Touch Screen vs. Hard Key Operation
Explains how to operate the application using either the touch screen or physical keys.
PSAnalyzer Screen Layout
Overview of the different display areas and information presented on the screen.
Menu Navigation and Controls
How to navigate through menus using hard keys and the 5-way navigator.
Power Saving and Shutting Down
Methods for turning off the unit or enabling auto-sleep for battery conservation.
PSAnalyzer Menu System
Home Menu Overview
Description of the main menu structure and navigation principles.
Menu Functions Summary
Brief descriptions of the functions available in each main menu.
Mode Menu Functions
Allows selection of operating modes like Centre/Span, Start/Stop, Zero Span, and Quick Menu.
Centre Frequency Menu
Details on how to set the centre frequency of the sweep.
Span and Step Value Menus
Functions for setting the sweep span and step values for frequency adjustments.
Start and Stop Frequency Menus
Procedures for setting the start and stop frequencies of the sweep.
AM/FM, Level, and Marker Menus
Controls for audio demodulation, reference level, and marker settings.
Sweep and Traces Menus
Options for selecting sweep modes, RBW, and managing trace displays.
Stores and System Menus
Functions for storing data, managing settings, and system configurations.
Exit and Quick Menu
Options to exit the application and details on the Quick Menu mode.
PSAnalyzer Operating Techniques
Menu Navigation Tips
Tips for navigating menus using hard keys and the hidden key.
Frequency Setting Methods
Overview of different modes for setting sweep frequencies.
Frequency Setting Shortcuts
Shortcuts for setting centre, span, start, and stop frequencies.
Numeric Entry and Tab/Jog
Methods for entering frequencies via keypad or navigator controls.
Performing Sweeps and Levels
How to start, stop, and control sweeps, and make level measurements.
Preset Key and Marker Usage
Using the Preset key for quick setup and controlling markers.
Reference Traces and Data Storage
Managing reference traces and storing/recalling instrument data.
Limit Lines and Display Settings
Creating limit lines and adjusting screen resolution/trace thickness.
Input Area and Brightness Adjustments
Changing input types and adjusting display brightness.
Help and External Functions
Accessing Help Screens
Information on accessing context-sensitive help screens and system info.
Viewing and Printing Screen Images
How to view stored screen images and print them via a PC.
Transferring Files to PC
Methods for transferring PSAnalyzer files using the USB card reader.
Using the Memory Card Reader
Installation and file transfer procedures for the USB memory card reader.
PSAnalyzer Files and Defaults
Factory Default Settings
Lists the default configurations for PSA1301 and PSA2701 models.
File Locations and Structures
Specifies where PSAnalyzer data files are stored and their formats.
Maintenance and Calibration
Screen Protection
Advice on using screen protectors for the touch screen.
Cleaning Procedures
Instructions for cleaning the instrument, especially the touch screen.
Battery Maintenance
Tips for maintaining the health of rechargeable batteries.
Calibration Checks
Information on the importance and frequency of calibration checks.
Troubleshooting Guide
Resolving PSAnalyzer Issues
Steps to resolve unexpected conditions within the PSAnalyzer application.
Resetting the Palm T|X
Procedures for performing soft and hard resets on the Palm T|X handheld computer.
Reinstalling PSAnalyzer
Instructions for reinstalling or updating the PSAnalyzer application.
Optional Accessories
Information on available optional accessories for the PSA1301/2701T and Palm T|X.
Creating Application Shortcuts
How to create hard key or favourites shortcuts for launching PSAnalyzer.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the PSA1301T and is the answer not in the manual?
Questions and answers