Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
TTI Manuals
Measuring Instruments
PSA1302
Instruction manual
TTI PSA1302 Instruction Manual
2.7ghz & 1.3ghz spectrum analyzers
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
page
of
61
Go
/
61
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
1 Product Introduction
Items Supplied
Using this Manual - Cross References
Product Description and Capabilities
Initial Use - Charging the Battery | Switching on
2 Safety Information
3 Basics of Operation
External Connections
DC Power Input
RF Signal Input
Demodulated Audio Output
USB Host Connector (for USB Flash Memory)
USB Device Connector (for Connection to a PC)
Trigger Input/Output
Bench-Top and Portable Use
Tilt Stand
Screen Protector and Sun Shield
Batteries and AC Line Power
Battery Operation
AC Line Operation
Power Saving for Battery Operation
Display and Controls Layout
Touch Screen Operation
Finger Tip Operation
Stylus Operation
Operation Using Only the Hard Keys
Navigator Keys - Mode Selection
Instrument Status Information
On-Screen Help
4 Operation Using the Menu System
Setting the Frequency Range of the Sweep
Centre
Span
Start/Stop
Step Size
Frequency Presets
Sweep Time
Zero Span Mode
Setting the Sweep Mode and Sweep Bandwidth (RBW)
Rbw
Video Filter
Sweep
Sweep Rate and the Sweep Progress Indicator Line
Manually Controlling the Sweep
Triggered Sweep (When Fitted)
Setting the Level Attenuator, Amplitude Scale, and Limits
Measurement Units and Graticule
Reference Level
Vertical Scaling
Amplitude Offset and Compensation Tables (When Fitted)
Amplitude Limits (When Fitted)
Controlling and Storing Traces and Images
Displaying Traces; Controlling the View Trace
Understanding the Live, View and Reference Traces
Sweep Progress Indicator Line
Setting the Trace Writing Mode
Storing and Recalling Traces and Screen Images
Using Measurement Markers
Setting-Up Markers
Controlling Markers
Controlling Markers with the Hard Keys
Further Notes on the Use of Markers
Data Logging Functions (When Fitted)
Setting-Up the Logging Function
Storing and Recalling Set-Ups | System Settings
Storing and Recalling Instrument Setups
System Settings, Screen Brightness, Filing System and USB Operations
Status Information | On-Screen Help | System Utilities
Status Display
Help Screens
System Utilities
Screen Utilities
Power Options, Power-On State, Clock Setting
Alerts
System Updating and Calibration
Using Instrument Presets | Automatic Setting
The User Preset
Custom Presets (When Fitted)
5 File Storage, File Types and USB Connections
Storing Traces or Screens
Default File Name Rules
Recalling Traces and Images
Traces and States
Storing Instrument Set-Up Files
File Recall Screen
File Utilities Screen
File Operations Screen
Editing File Names
File Names Created or Renamed Externally
Internal Filing System Organisation
Understanding USB Connections
Using an External Flash Drive
Linking to a PC Via USB
File Types
Trace Files
Screen Image Files
Setup Files
Other File Types
Compensation Tables
Limit Pattern Tables
Logging Files
6 Upgrade Option U01
Additional Functions from Option U01
Logging of Values, Traces or Screens
Triggering
Limit Lines and Patterns
Level Offsets
Compensation Tables
View on PC
Custom Presets
PSA-Manager Software
7 Further Notes on Operation
Operation Using the Hard Keys Only
Setting Frequencies
Set by Keyboard
Set by Tab/Jog
Shortcuts to Setting a Specific Frequency Span
Repetitive Operations
Using Custom Presets (When Available)
Measuring Relative Amplitude
Triggered Operation
External Trigger Input
Trigger Output
Level Offset and Compensation Tables
Dynamic Range and Maximum Signal
Creating and Using Compensation Tables
Limit Lines & the Limits Comparator | Creating Limit Patterns
Setting Limits
The Limit Comparator
Creating and Loading Limit Patterns
Limit Offset
Limit Fix/Unfix
The Logging Function
The Logging Control Menu
Manual Logging
The Run/Stop Key and Sweep Control Key
Logging from the Timer
Logging from External Trigger
Logging from Amplitude Limits
Logging Every Sweep (Continuous)
File Sizes and Maximum Logging Times
Viewing and Analyzing Logging Files
8 Default Settings | Power on State |Hard Reset
Standard Preset
Factory Default Set-Up
Restoring to Factory Defaults
Power-On State
Unrecoverable Fault Condition - Hard Reset
9 Firmware Updates | Upgrades | Maintenance
Updating the Firmware
Upgrading the Firmware (Option U01)
Maintenance, Re-Calibration & Cleaning
10 Emc
11 Declaration of Conformity
12 Specification
Frequency Measurement
Amplitude Measurement (Level)
Traces
Sweep
Data Logging (Only with Option U01)
Demodulation (Zero Span Mode)
Display
Memory Storage
Connectors
AC Line Operation
Battery Operation
Mechanical
Environmental and Safety
13 Appendix A: PSA-Manager and PSA-View Software
14 Appendix B: Optional Accessories
15 Appendix C: Menu Tree Diagram
Advertisement
Quick Links
1
Setting the Frequency Range of the Sweep
2
Operation Using the Menu System
Download this manual
PSA2702 & PSA1302
2.7GHz & 1.3GHz Spectrum Analyzers
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the PSA1302 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for TTI PSA1302
Measuring Instruments TTI PSA2702 Instruction Manual
2.7ghz & 1.3ghz spectrum analyzers (61 pages)
Measuring Instruments TTI PSA2701T Instruction Manual
1.3ghz & 2.7ghz rf spectrum analyzers; thurlby thandar instruments (47 pages)
Measuring Instruments TTI PSA1301T Instruction Manual
1.3ghz & 2.7ghz rf spectrum analyzers; thurlby thandar instruments (47 pages)
Measuring Instruments TTI PFM3000 Instruction Manual
Portable frequency meter (21 pages)
Measuring Instruments TTI 1604 Service Manual
Digital multimeter (22 pages)
Measuring Instruments TTI LD300 Service Manual
300w dc electronic load (51 pages)
Measuring Instruments TTI TTIDM1000VAR Operating Instructions Manual
Auto-ranging multimeter (24 pages)
Measuring Instruments TTI PROFESSIONALS TTICM1000V Operating Instructions Manual
600a ac clamp meter, auto ranging (20 pages)
Measuring Instruments TTI PROFESSIONALS TTICM600V Operating Instructions Manual
400a ac/dc clamp meter auto ranging (20 pages)
Measuring Instruments TTI FTE-7000A User Manual
Optical time domain reflectometer (50 pages)
Measuring Instruments TTI FTE-7000A-DWDM User Manual
Optical time domain reflectometer (59 pages)
Measuring Instruments TTI FTE6100 User Manual
Tunable laser source (26 pages)
Summarization of Contents
Product Introduction
1.1 Items Supplied
Lists all components included with the spectrum analyzer.
1.2 Using this Manual - Cross References
Explains how to navigate and use cross-references within the manual.
1.3 Product Description and Capabilities
Details the features and capabilities of the PSA2702 and PSA1302 spectrum analyzers.
Safety Information
Basics of Operation
3.1 External Connections
Details the instrument's input and output connectors for power, signals, and peripherals.
3.2 Bench-top and Portable Use
Describes how to set up and use the instrument in both bench-top and portable configurations.
3.3 Batteries and AC Line Power
Covers battery operation, AC line power, and power saving features for extended use.
3.4 Display and Controls Layout
Provides an overview of the instrument's display screen and physical control buttons.
3.5 Touch Screen Operation
Explains how to operate the instrument using the touch screen interface and its modes.
3.6 Instrument Status and On-screen Help
Accesses current instrument status information and context-sensitive help.
Operation using the Menu System
4.1 Frequency and Sweep Settings
Manages frequency range, sweep time, zero span, and sweep mode/bandwidth.
4.2 Level, Amplitude, and Trace Control
Adjusts level settings, amplitude scaling, limits, and controls traces/markers.
4.3 Data Logging and System Settings
Configures data logging and manages instrument setup storage and system functions.
4.4 Instrument Presets and Status
Utilizes presets for quick setup, accesses status, help, and system utilities.
File Storage, File Types and USB Connections
5.1 Storing and Recalling Data Files
Covers saving and retrieving traces, screens, and instrument setups.
5.2 File Management and USB Operations
Details file operations, utilities, and USB connectivity for data transfer.
5.3 File Types and PC Software Integration
Explains various file formats and PSA-View/Manager software integration.
Upgrade Option U01
6.1 Additional Functions from Option U01
Details features added by Option U01, including logging, triggering, and limits.
Further Notes on Operation
7.1 Hard Key Operation
Explains operating the instrument using only the physical control keys.
7.2 Setting Frequencies
Provides methods for setting frequencies using keyboard, tab/jog, and shortcuts.
7.3 Measuring Relative Amplitude
Describes how to measure amplitude differences between markers.
7.4 Triggered Operation
Details sweep and logging triggering using external or internal sources.
7.5 Level Offset and Compensation Tables
Manages level offsets and compensation tables for accurate amplitude measurements.
7.6 Limit Lines and Comparator
Sets and uses limit lines/patterns for automated actions and comparisons.
7.7 The Logging Function
Controls logging of sweep data, defining triggers and file storage.
Default Settings, Power On State & Hard Reset
8.1 Standard Preset
Restores the instrument to a known set of default operating conditions.
8.2 Factory Default Set-up
Describes the instrument's initial state as shipped from the factory.
8.3 Power-On State Configuration
Configures the instrument's behavior upon startup (e.g., Last Used, User Preset).
8.4 Hard Reset Procedure
Explains how to perform a hard reset to recover from unrecoverable faults.
Firmware Updates, Upgrades & Maintenance
9.1 Updating the Firmware
Process for updating instrument firmware to add features or fix bugs.
9.2 Upgrading the Firmware (Option U01)
Procedure for installing the U01 firmware upgrade with activation.
9.3 Maintenance, Re-calibration & Cleaning
Guidelines for instrument upkeep, calibration, and cleaning procedures.
EMC Compliance
Emissions and Immunity Standards
Details the instrument's compliance with EMC directives for emissions and immunity.
Declaration of Conformity
EC Declaration of Conformity
Formal statement of compliance with European directives for safety and EMC.
Specification
12.1.1 Frequency Measurement Specifications
Specifies frequency range, span, resolution, and accuracy parameters.
12.1.2 Amplitude Measurement Specifications
Details amplitude range, accuracy, noise floor, and distortion specifications.
12.1.3 Trace Specifications
Describes graticule, displayed points, trace modes, and reference trace options.
12.1.4 Sweep Specifications
Specifies sweep method, time, modes, and trigger capabilities.
12.1.5 Data Logging Specifications
Outlines data logging file capabilities, triggers, and time intervals.
12.1.6 Demodulation Specifications
Specifies demodulation modes, audio output, and filter settings.
12.1.7 Display Specifications
Details display type, resolution, and graticule options.
12.1.8 Memory Storage
Covers memory types and storage/recall capabilities for traces, screens, and setups.
12.1.9 Connector Specifications
Lists and describes the instrument's input and output connectors.
12.1.10 AC Line Operation
Details continuous operation using AC power and battery recharging.
12.1.11 Battery Operation
Specifies battery type, life, recharge time, and auto-sleep modes.
12.1.12 Mechanical Specifications
Provides physical dimensions, weight, tilt stand, and screen protector details.
12.1.13 Environmental and Safety Specifications
Outlines operating/storage ranges, environmental conditions, and safety compliance.
Appendix A: PSA-Manager and PSA-View Software
PSA-Manager Software Functions
Explains PC software for file creation, editing, analysis, and management.
PSA-View Software Application
Describes PC application for viewing the instrument's display remotely via USB.
Appendix B: Optional Accessories
Optional Accessories List
Lists available accessories and firmware upgrades for the instrument.
Appendix C: Menu Tree Diagram
Menu Tree Diagram
Visual representation of the instrument's menu structure and navigation paths.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the PSA1302 and is the answer not in the manual?
Questions and answers