Page 2
This manual covers the following appliances: Single burner: Clear 40 RS/LS/TS/Tunnel, Stand Alone 40 TS, Clear 40H90 RS/ ® LS/TS/Tunnel, Clear 40H70 RS/LS/TS/Tunnel, Small Square, Corner Classic/ Modern , 4 glass 14 Harash St. Neve Neeman, Hod Hashron, 45240, Israel P.O Box 7213...
Page 3
NEW LOGS ( 6 pcs SET) 1 SET The Building Regulations issued by the Department of the Environment, the The Building Regulations issued by the Department of the Environment, the The Building Regulations issued by the Department of the Environment, the The Building Regulations issued by the Department of the Environment, the Flue Design Options Building Standards (Scotland) (Consolidation) Regulations issued by the Scottish...
Page 4
If the appliance is located in a recess, then the recess must have adequate This appliance can be installed in a completely sealed or mechanically ventilated ventilation, we recommend a minimum total vent area of 600 cm². house without extra ventilation and/or fume extraction. General Balanced Flue Notes The stove must be located at least 280mm from any combustible materials.
Page 5
INSTALLER INFORMATION Terminal Locations Roof Termination “Distance” = minimum distance required for positioning of the outlet to avoid adverse effects with respect to: A ventilation opening serving an occupied room, a toilet or a bathroom A heating air supply, when the supply flows through an occupied room. A window that can be opened and that is near an occupied room, a toilet or a bathroom.
COMMISSIONING THE STOVE A soundness test MUST be made before the installed stove is left with the Burner – 30 Clear 40 RS/LS/TS/Tunnel, Stand Alone 40 TS, Clear 40H90 RS/LS/TS/ customer. Tunnel, Clear 40H70 RS/LS/TS/Tunnel, Small Square, Corner Classic/ Modern , Ensure that the fire is burning at full rate for a minimum of 5 minutes to warm the flue.
Page 7
Troubleshooting Countries of Destination The gas pilot will not ignite or stay lit? The following tables gives detail of the Countries that these appliances are approved Ensure the gas is turned on at the appliance and the meter/cylinder. for use within. The tables following immediately on give the technical characteristics of the appliances.
Page 9
Instructions for changing Burner from Natural Gas to LPG General Notes Although it is possible to modify the Burner from Natural to LPG in the appliance, we would recom mend removing the burner from the appliance. This is done by removing the door and window, remove the Grate Plates which will then give access to the burner base.
Page 10
Measuring the Burner Pressure. The picture below shows 9.2 Setting the burner pressure. There are two different types of control the two Pressure Measuring Tappings available on the control. used for this burner, the FULLY REMOTE and SEMI REMOTE, the There is an arrow by each tapping.
Page 11
Contents- Single Step Burner (N) 1. Injector: 0.30M burner: marked Bray 220 for LPG & Bray 650 for Natural Gas which reveals the setting screw. 0.45M burner: marked Bray 220 for LPG & Bray 650 for Natural Gas 1.00M burner: marked Bray 260 for LPG & Bray 1200 for Natural Gas 1.35M burner: marked Bray 380 for LPG &...
Page 12
Output Class fireplace hood. The Ortal direct vent appliances have been tested and approved by CSA for safety and efficiency for use with either Natural Gas (NG) or Propane (LP). 0.30m Recommendation: Ortal recommends the use of high temperature paint (rated 175° F burner or higher) on the underside of the mantel.
Page 13
Clear 40 Tunnel, Stand Alone 40 TS Clear 40 Tunnel, Stand Alone 40 TS The Ortal direct vent appliances have been tested and approved by CSA for safety and The Ortal direct vent appliances have been tested and approved by CSA for safety and efficiency for use with either Natural Gas (NG) or Propane (LP).
Page 14
Clear 40 Tunnel, Stand Alone 40 TS Clear 40 Tunnel, Stand Alone 40 TS The Ortal direct vent appliances have been tested and approved by CSA for safety and The Ortal direct vent appliances have been tested and approved by CSA for safety and efficiency for use with either Natural Gas (NG) or Propane (LP).
Page 15
Clear 40 Tunnel, Stand Alone 40 TS Clear 40 Tunnel, Stand Alone 40 TS The Ortal direct vent appliances have been tested and approved by CSA for safety and The Ortal direct vent appliances have been tested and approved by CSA for safety and efficiency for use with either Natural Gas (NG) or Propane (LP).
Page 16
DECORATION ARRANGEMENT English Long Branch & English Short Branch Burner – 30 Clear 40 RS/LS/TS/Tunnel, Stand Alone 40 TS, Clear 40H90 RS/LS/TS/Tunnel, Clear 40H70 RS/LS/TS/Tunnel, Small Square, Corner Classic /Modern Burner- 45 Clear 75 RS/LS/TS, Stand Alone 75 /TS, Space...
Page 17
Burner 100 3 LONG BRANCHES & 9 SHORT BRANCHES + 2 Bag Beige Embers 75 RS/LS/TS, Stand Alone 75 /TS, Space Creator 75, 75 Hark RS/LS/TS, 60x80 OVAL, Classic F 75/80, 80 RS/LS/TS, 80H70 RS/LS/TS Clear 110/Tunnel, Stand Alone 110, Clear 110H /Tunnel, Clear 130, Island 130, 130 Top 2 LONG BRANCHES &...
Page 18
6 LONG BRANCHES & 12 SHORT BRANCHES +2 Bag Beige Embers Burner 135 4 LONG BRANCHES & 11 SHORT BRANCHES +2 Bag Beige Embers 170 RS/LS/TS/Tunnel Clear 150, Stand Alone 150 4 LONG BRANCHES & 11 SHORT BRANCHES +2 Bag Beige Embers Burner 160 6 LONG BRANCHES &...
Page 19
TS, 60x80 OVAL, Classic F 75/80, 80 RS/LS/TS, 80H70 RS/LS/TS Burner 30 Only Three Small + 1 Bag Beige Embers Clear 60x80 /Tunnel, Clear 40 RS/LS/TS/Tunnel, Stand Alone 40 TS, Clear 40H90 RS/LS/TS/Tunnel, Clear 40H70 RS/LS/TS/Tunnel, Small Square, Corner Classic/ Modern...
Page 20
2 SET’S + 2 Bag Beige Embers Clear 75x65 /Tunnel, , 4 glass Island, 130 RS/LS/TS/Tunnel, Space Creator 120, 4 glass 2 burners Clear 250 RS/LS/TS/Tunnel Burner 100 Burner 135 2 SET’S + 1 Bag Beige Embers 2 SET’S + 2 Bag Beige Embers Clear 110/ Tunnel, Stand Alone 110, Clear 110H /Tunnel, Clear 150, Stand Alone 150 Clear 130, Island 130, 130 Top...
Need help?
Do you have a question about the Space Creator120 and is the answer not in the manual?
Questions and answers