9 Specifications
This chapter provides the power requirements, operating conditions (environmental requirements), physical
requirements, hardware specifications, and video resolutions of the HP Server tc3100.
The following tables provide the specifications required for normal operation of the HP Server tc3100.
NOTE
The specifications and requirements for the power supply and environment can vary if
you install a mass storage device in the server that has more stringent environmental limits
than required for the HP Server. Ensure the operating environment for any mass storage
devices you intend to install are compatible with the server environmental requirements.
Power Supply Requirements
Parameter
Input Type
Input Voltage
Operating Current
In-rush Current
Operating Power
Environment
Parameter
Temperature
Operating
Non-operating
Humidity
Operating
Non-operating
Altitude
Operating
Non-operating
Thermal Output
Maximum Operating
Acoustic Emissions
Characteristics
Wide-ranging, PFC
100 to 127 VAC ± 10%, 50/60 Hz
200 to 240 VAC ± 10%, 50/60 Hz
100 VAC:
3.49 A, 345 W
120 VAC:
2.69 A, 339 W
200/208 VAC:
1.80 A, 329 W
220/230 VAC:
1.56 A, 325 W
50 A peak, 240 VAC
320 W Continuous
Conditions
5° to 35° C (41° to 95° F)
-40° to +65° C (-40° to +149° F)
20% to 80% relative humidity,
non-condensing
5% to 95% relative humidity,
non-condensing
-30 to 3,000 m (~ 10,000 ft)
-30 to 12,000 m (~ 40,000 ft)
1662 BTU/hr
Sound level (LpA): <40 dB(A)
97