Chapter 7
14. Remove the replacement system board and any cables from the anti-static shipping container.
15. Place the system board on an anti-static pad and set all jumper connections and settings as recorded
during the system board removal.
16. Place the system board in the chassis aligning the rear panel connectors to the rear chassis and the
mounting holes in the board with the holes in the chassis.
17. Snap the board into place.
18. Install the eight screws securing the system board to the chassis.
19. Replace memory, processors and/or CPU terminator.
NOTE
A tube of grease is provided with the replacement system board. One half of the tube
should be used for each processor.
a. Wipe the grease off of the heatsink and processor.
b. Place a round dollop of the grease in the center of the CPU heat spreader.
c. Push the heatsink straight down to evenly spread the grease.
d. Install the heatsink to the CPU.
20. Replace all cables that were removed.
21. Replace any removed accessory boards.
22. Return the machine to its upright position.
23. Replace the system fan.
24. Connect the power cord and any external cables to the server.
25. Close the side panel.
26. Power up the server and return it to normal operation.