4.7.4 03-0011 Forced Transmission
Transmission is done, regardless of the flow control between the TM printer and the UB-E02.
4.7.4.1 Set-up data
Off-set
Size
14
1
15
2
17
n
4.7.4.2 Reply data
Off-set
Size
14
1
15
2
17
n
4.7.5 03-0012 Reset
4.7.5.1 Set-up data
Off-set
Size
14
1
4.7.5.2 Reply data
Off-set
Size
14
1
To reset the printer, the reset function should be enabled by a DIP switch of the printer.
The UB-E02 is also reset when the printer is reset.
After resetting, wait for approximately 10 seconds before accessing to the UB-E02, which is
the same as when turning on the power.
Rev. A
Description
Flow control
0: With flow control
1: No flow control (forced transmission)
Data length (n: maximum: 255)
Data length (maximum: 255)
Description
Result
0: Normal
Except for 0: Failure
Data length
Data string
Description
Reserved (undefined)
Description
Result
0: Normal
Except for 0: Failure
UB-E02 Technical Reference Guide
4-9 Programming Samples