Maintenance

Hayward pumps have self-lubricating motor bearings and shaft seals. No lubrication is necessary.
Keep motor clean. Insure motor air vents are free from obstruction to avoid damage. Do NOT use water to hose off
motor.
Occasionally, shaft seals must be replaced, due to wear or damage. Replace with genuine Hayward seal assembly kit.
See "Shaft Seal Change Instructions" in this manual.
Storage/Winterization
ATTENTION –
ATTENTION –
toxic and will not damage plastic system components; other anti-freezes are highly toxic and may damage plastic components
in the system.
Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time (see
instructions below). Gravity drain system as far as possible.
Keep motor dry and covered during storage. To avoid condensation/corrosion problems, do NOT cover or wrap pump with
plastic film or bags.

Storing Pump For Winterization

Shaft Seal Change Instructions

When servicing electrical equipment, basic safety precautions should always be observed including the following. Failure to follow
instructions may result in severe personal injury or death.
WARNING –
A.
B. Disconnect all electrical power service to pump before beginning shaft seal replacement.
C. Only qualified personnel should attempt rotary seal replacement. Contact your local authorized Hayward Dealer or
service center if you have any questions.
Exercise extreme care in handling both the rotating and the stationary sections of the two-part replacement seal. Foreign matter or
improper handling will easily scratch the graphite and ceramic sealing surfaces.
WWW.HAYWARDPOOL.COM
WARNING –
Separation Hazard. Do not purge the system with compressed air. Purging
the system with compressed air can cause components to explode, with risk of severe injury or death to
anyone nearby. Use only a low pressure (below 5 PSI), high volume blower when air purging the pump,
filter, or piping.
Allowing the pump to freeze will void the warranty.
Use ONLY propylene glycol as antifreeze in your pool/spa system. Propylene glycol is non-
WARNING –
before draining pump. Failure to disconnect power may result in serious personal injury or death.
1. Turn booster pump off before turning off the filtration system pump.
2. Turn the filtration system pump off.
3. Remove drain plug from seal plate (see Parts Diagram on page 11 of this manual for pump
component locations), and completely drain water from booster pump.
4. Winterize above and below ground piping in accordance with winterizing practices.
5. Refer to pressure cleaner owner's guide for cleaner system winterizing practices.
IMPORTANT SAFETY INSTRUCTIONS
PLEASE READ AND FOLLOW ALL INSTRUCTIONS
To reduce risk of injury, do not permit children to use this product.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
_____________________________ Page 9 of 16
To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor