Known Problems

1. Dual homed systems: If you have a problem communicating with your arrays on a dual
homed system, including failure of the armdiscover command, there are several items that
should be investigated:
Check to make sure the following file exists
o
/opt/sanmgr/hostagent/config/commIpAddr.txt
This file contains the IP address of the default or onboard NIC (LAN0). If the file
does not exist, you should create it.
The netconf file can tell you the IP address of LAN0. It is found in the following
o
directory:
/etc/rc.donfig.d
Settings in the following files in the /etc directory should also be checked:
o
hosts - Lists hostname of system with its associated IP address. The first host
resolv.conf - The first nameserver listed needs to be on the same network as

HP NAS VA User's Guide (Print Version)

82
entry needs to be the default (LAN0) setting.
the default (LAN0).