P M-UP (MIC-UP PG)
Function: One of 52 functions can be preset and
assigned to the [ UP ] key of the micro-
phone.
Available Values: Please see page 16.
Default: UP
Presets of various functions can be assigned to the
[ UP ] key of the microphone using this option.
PEAKHLD (METER PEAK HOLD )
Function: Peak hold setting of S meter.
Available Values: ON/OFF
Default: ON
When this function is set to on the peak S meter read-
ing is held for 0.5 seconds to improve readability.
PNL-C.S
Function: One of 53 functions can be preset and as-
signed to the [ VOICE/C.S ] key.
Available Values: Please see page 16.
Default: VCC
Presets of various functions can be assigned to the
[ VOICE/C.S ] key using this option.
Please see page 16 for a detailed explanation.
QSPL F (QUICK SPLIT FREQ)
Function: offsets the transmit frequency.
Available Values: -20 ~ 0 ~ +20 (kHz)
Default: +5
The Quick Split feature allows you to set a one-touch
offset to be applied to your radio's transmit frequency
compared to the receiving frequency. Also, the trans-
mit mode is set to the same mode as the receive
frequency (See page 41).
RFPOWER (RF PWR SET)
Function: Sets the maximums transmit power level
for the current band.
Available Values: 5 ~ 100 (W)
Default: 100 (W)
RPT (REPEATER SHIFT DIRECTION)
Function: Sets the Repeater shift Direction
Available Values: -SHIFT / SIMPLEX / +SHIFT
Default: SIMPLEX
RPT SFT (REPEATER SHIFT OFFSET)
Function: Sets the magnitude of the repeater shift
on the 28/50MHz band.
Available Values: 0.00 ~ 99.99 (MHz)
Default: HF: 0.10 (MHz) / 50 MHz: 1.00 (MHz)
The FT-450 may be utilized on 29 MHz and 50 MHz
repeaters.
A
:
The conventional repeater shift used on 29 MHz is
100 kHz, while on the 50 MHz band the shift may
vary between 500 kHz and 1.7 MHz (or more). To
program the proper repeater shift, use Menu Item
"RPT SFT" (see page 53).
FT-450 O
in 1kHz increments
M
M
ENU
RTY SFT (RTTY-SHIFT)
Function: Selects the frequency shift for FSK RTTY
operation.
Available Values: 170 / 200 / 425 / 850 (Hz)
Default: 170
RTY TON (RTTY-TONE)
Function: Selects the Mark tone for RTTY opera-
tion.
Available Values: 1275 / 2125 (Hz)
Default: 2125
RTYRPOL (RTTY-RX-POLARITY)
Function: Selects normal or reverse Mark / Space
polarity for RTTY receive operation.
Available Values: NOR/REV
Default: NOR
RTYTPOL (RTTY-TX-POLARITY)
Function: Selects normal or reverse Mark / Space
polarity for RTTY transmit operation.
Available Values: NOR /REV
Default: NOR
SCN RES (SCAN RESUME)
Function: Sets the delay time for scan resume.
Available Values: BUSY / TIME1 ~ 10 (sec)
Default: RIME5 (sec)
SELDIAL (SEL DIAL MODE)
Function: Assigns a second function to DSP/SEL
knob that is activated when the DSP/SEL
knob is momentarily depressed.
Available Values: CWSTONE / CWSPEED
/ 100KHZ /1MHZ/MICGAIN
/ RFPOWER
Default: 100KHZ (100 kHz)
CWSTONE: CW SIDETONE LEVEL
CWSPEED: CW KEYER SPEED
100KHZ:
100KHz Step
1MHZ:
1MHz Step
MICGAIN:
MIC GAIN SET
RFPOWER: RF POWER SET
SQL TYP (SQL TYPE)
Function: Selects the Tone Encoder and/or Decoder
mode.
Available Values: OFF / ENC / ENC/DEC
Default: OFF
OFF:
The function of "SQL knob" that exists in
the front panel is selected.
ENC:
CTCSS Encoder
ENC/DEC: CTCSS Encoder/Decoder(Tone Squelch)
SQL/RFG (SQL/RF GAIN)
Function: Selects the configuration of the front
panel's SQL/RF knob.
Function: SQL/RF-GAIN
Default: RF-GAIN
M