Graphic Meter Display; Swept Swr Display - Yaesu FT DX 9000 TFT Manual

Tft
Table of Contents

Advertisement

VDD
The drain voltage of the final FET is measured
and displayed here. The measurement range is
0-60 V, and the proper voltage is around 50 V. On
TX, if around 50 V is displayed, the transceiver is
operating normally.
BIAS
While operating with the Class-A, and the bias is
changed by rotating the BIAS knob from class A to
class AB, this indication can be used to observe the
current setting. The indication is 0-100 % and "0%"
means class AB, while "100%" means class A.
Even if the Bias is varied, the RF output will not
change (up to the 75 Watts of maximum power
under class A), and you can change the bias safely
even when you are using a linear amplifier.
TEMP
This indicates the temperature (measured) of the
final amplifier FETs' heat sink.
It is possible to show the SWR characteristics and antenna performance on a graph by measuring the SWR at
various points across an amateur band.
In order to measure the SWR of the antenna system
correctly, please turn off the antenna tuner before
measuring the SWR.
1. Please confirm that the RF output is over 10 Watts.
In order to measure the SWR correctly, 10 Watts
of RF output will be required. The TX RF output
may be adjusted using the RF PWR knob.
2. Please confirm that the test transmission will not
cause QRM to other stations (be sure to ask if the
frequency is clear, and identify in accordance with
regulations). Then press the [ F6 ]( SWR CK ) key.
3. Perform the above procedure several times across
the band, and the SWR measured at the various
test frequencies will automatically be plotted on
FT
9000 TFT O
DX
T
EMPERATURE
G
RAPHIC
S
WEPT
M
PERATION
ANUAL
/ SWR I
M
D
ETER
ISPLAYS
The measured temperature range of this meter is
0 - 100 °C, and above 80 °C is the "Red Zone"
temperature range to be avoided, so as to ensure
a safe operating temperature range. When the
temperature rises above 80 °C, the fan speed will
increase by a factor of four, providing a signifi-
cant increase in air flow. The heat sink tempera-
ture may rise appreciably during Class-A opera-
tion, especially if the ambient temperature is warm,
and we recommend that you monitor the tempera-
ture during Class-A transmission, adjusting the
Bias control downward (more toward Class AB) if
excessive heating is observed. A lower bias level
will cause less heat to be dissipated, thus reduc-
ing the heat sink temperature.
SWR
This displays the SWR characteristic of the ama-
teur band that you are currently using, with points
along the graph indicating the frequencies that
have been measured.
SWR D
ISPLAY
the chart, creating a performance characteristic
graph for the current frequency range.
Advice: For the purposes of plotting the SWR across
the band, the resolution of the graph is every 10 kHz
on the 1.8 ~ 24 .9 MHz bands, and 100 kHz on the
28/50 MHz bands.
If a measurement is done on the same frequency as
where a previous measurement was made, the old
data will cleared and the new measurement data will
replace it.
Always observe proper operating courtesy to oth-
ers, and check to be sure the frequency is clear
before performing any SWR measurements.
NDICATION
Page 31