About sensor configuration
14
1
To reset the unit, set all six sensors to default sensor type
None.
2
Choose the sensor you wish to use for the PI Spread/Depth
sensor; 1 to 6.
3
Define the sensor type (by default None) to Dual.
4
Set
to the correct update rate.
Update
5
Set
to the chosen sensor type Spread.
Measure 1
6
Set the communication
7
Set
to the chosen sensor type Depth 300M, Depth
Measure 2
600M or Depth 1000M depending on the depth rating on
your PI Remote/Depth sensor.
8
Set the communication
9
Press the
button to save the changes and exit.
ENT
All sensors are provided with default communication channels
and update rates. Refer to the table in section About sensor
configuration on page 14.
All sensors are provided from Simrad with predefined
communication channels and update rates.
Default communication channels and
update rates
See the table below for the initial values for the communication
channels and update rates for the various sensors.
Table 1 Default communication channels and update rates
Sensor
PI Bottom Contact
PI Catch
PI Depth (300 m)
PI Depth (600 m)
PI Depth (1000 m)
PI Height
PI Remote/Depth
PI Spread
PI Spread/Depth
PI Twin Spread
to its correct value.
Channel
to its correct value.
Channel
Com.channel(s)
6
4
16
12
10
14
Depth 300M: 11
Depth 600M: 15
Depth 1000M: 13
2
Depth 300M: 16
Depth 600M: 12
Depth 1000M: 10
Spread: 2
2 and 7
Update rate
Normal
Normal
Fast
Fast
Fast
Fast
Fast
Fast
Fast
Fast
316870/A