Troubleshooting When Using the Copy Function
Problem
When using the Margin
Adjustment function,
parts of the original im-
age are not copied.
2
When using the Image
Repeat function, the orig-
inal image is not copied
repeatedly.
❖ Stamp
Problem
The stamp position is
wrong.
❖ Combine
Problem
Copies made with the
Booklet or Magazine
function cannot be folded
into a book correctly.
When using the Combine
function, parts of the im-
age are not copied.
Copies are not in correct
order.
❖ Duplex
Problem
Cannot print in duplex
mode.
Cannot print in duplex
mode.
Cannot print in duplex
mode.
22
Cause
There is a lack of margin
space on the opposite side
of the binding position.
You selected copy paper
the same size as the orig-
inals, or you did not se-
lect the proper
reproduction ratio.
Cause
The paper orientation is
wrong.
Cause
You selected a setting
("Open to Left" or "Open
to Right") that does not
match the orientation of
originals.
You specified a repro-
duction ratio that does
not match the sizes of
your originals and copy
paper.
You placed the originals
in the incorrect order.
Cause
You have loaded paper
on the bypass tray.
You have loaded paper
2
exceeding 105 g/m
.
You have selected a tray
which is set to [1 Sided
Copy] in [Tray Paper Set-
tings] in [System Settings].
Solution
Set a narrower margin with User Tools.
You can set the width between 0 - 30
mm (0" - 1.2").
See "Front Margin: Left / Right", "Back
Margin: Left / Right", "Front Margin:
Top / Bottom", and "Back Margin: Top
/ Bottom", General Settings Guide.
Select copy paper larger than the origi-
nals or select the proper reproduction
ratio.
Solution
Check the paper orientation and stamp
position.
Solution
Change the setting. See "Orientation:
Booklet, Magazine", General Settings
Guide.
When you specify a reproduction ratio
using the Manual Paper Select function,
check that the ratio matches your origi-
nals and the copy paper. Select the cor-
rect reproduction ratio before using the
Combine function.
When placing a stack of originals in the
ADF, the last page should be on the bottom.
If you place an original on the exposure
glass, start with the first page to be copied.
Solution
Remove paper loaded on the bypass
tray. Load paper in another tray.
Change the paper.
Set the tray to [2 Sided Copy] in [Tray Pa-
per Settings] in [System Settings]. See "Pa-
per Type: Tray 1-4", General Settings
Guide.