C O N T E N T S Introduction Limited Warranty (USA Only) Warranty Registration | Features Safety Precautions Overview Installation Guidelines Remote Device Management (RDM) Control Panel System Menu Aria DMX Set Up DMX Traits Pixel Zones RGB Macros Color Temperature Table Dim Modes and Curves Primary-Secondary Set Up | Multi Unit Power Linking...
I N T R O D U C T I O N Unpacking: Thank you for purchasing the Vintage X by ADJ Products, LLC. Every device has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping.
The sole responsibility of ADJ Products, LLC under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of ADJ Products, LLC. All products covered by this warranty were manufactured after August 15, 2012, and bear identifying marks to that effect.
W A R R A N T Y R E G I S T R A T I O N Please fill out the enclosed warranty card to validate your purchase. All returned service items, whether under warranty or not, must be freight pre-paid and accompanied by a return authorization (R.A.) number.
S A F E T Y P R E C A U T I O N S PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED. THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY REPAIRS YOURSELF, AS DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY.
Page 8
S A F E T Y P R E C A U T I O N S • Ambient operating temperature range is 14°F to 113°F (-10°C to 45°C)! • DO NOT expose to rain or moisture, or spill liquids into or onto the device! Any damage resulting from these conditions may void the manufacturer’s warranty.
O V E R V I E W Yoke Omega Bracket Mounting Display Wireless Points Screen Status Indicators Wireless MENU DOWN ENTER Safety Body Menu Down Enter Cable Omega Button Button Button Button Loop Bracket (Installed) Mounting Yoke Yoke Fuse Power Power Adjustment...
I N S T A L L A T I O N G U I D E L I N E S DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO! Fixture MUST be installed following all local, national, and country commercial electrical and construction codes and regulations.
I N S T A L L A T I O N G U I D E L I N E S CLAMP MOUNTING This fixture features mounting holes on the top of the mounting yoke or on the rear of the fixture near the display screen for the attachment of an Omega bracket (the image below shows the Omega bracket mounted onto the rear of the unit).
Page 12
I N S T A L L A T I O N G U I D E L I N E S The unit is fully operational in three different mounting positions: hanging upside-down from the ceil- ing or trussing, sideways on trussing, or set on a flat level surface. Be sure this fixture is kept at least 9.8 ft (3m) away from any flammable materials (decorations, etc).
Page 13
LEDs. This issue is not specific only to ADJ lighting fixtures, it is a common issue with lighting fixtures from all manufacturers. Although there is no true way to fully prevent this issue from happening, the guidelines below can prevent any potential damage from occurring if followed.
R E M O T E D E V I C E M A N A G E M E N T ( R D M ) R E M O T E D E V I C E M A N A G E M E N T ( R D M ) NOTE: In order for RDM to work properly, RDM enabled equipment must be used throughout the entire system, including DMX data splitters and wireless systems.
S Y S T E M M E N U OPTIONS / VALUES (Default Settings in BOLD) MAIN MENU DMX Address 001 - 512 13ch 22ch 39ch 43ch DMX Channel Mode 196ch 200ch SETTINGS 208ch 211ch User Mode Hold Last Blackout No DMX Manual...
Page 17
S Y S T E M M E N U OPTIONS / VALUES (Default Settings in BOLD) MAIN MENU Linear Square Dim Curve Inv Squa S Curve Intensity 1 - 10 Display Invert Yes / No Display Screen Saver Off - 30sec, 1min, 5min, 10min Delay Key Lock Off / On...
S Y S T E M M E N U OPTIONS / VALUES (Default Settings in BOLD) MAIN MENU Red 1 000 - 255 Green 1 000 - 255 Blue 1 000 - 255 Red 2 000 - 255 MANUAL CONTROL Program Speed 000 - 255...
A R I A 2.4GHZ VERSUS SUB-GIG (GHZ) FREQUENCIES: Sub-GHz frequencies provide superior reliability and range compared to higher frequencies, making them perfect for consistent communication across vast distances or in difficult conditions. Devices operating in the sub-GHz range, which refers to frequencies below 1 GHz, can transmit signals over significant distances and can penetrate physical barriers such as walls and buildings more effectively.
D M X S E T U P DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used as a form of commu- nication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN”...
2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will reduce the risk of erratic behavior. DMX ADDRESSING.
D M X T R A I T S Features subject to change without notice MODE / CHANNELS VALUES FUNCTION 13CH 22CH 39CH 43CH 196CH 200CH 208CH 211CH Red All 000-255 0 - 100% Green All 000-255 0 - 100% Blue All 000-255 0 - 100%...
Page 23
D M X T R A I T S Features subject to change without notice MODE / CHANNELS VALUES FUNCTION 13CH 22CH 39CH 43CH 196CH 200CH 208CH 211CH Red Group 6 000-255 0 - 100% Green Group 6 000-255 0 - 100% Blue Group 6 000-255 0 - 100%...
Page 24
D M X T R A I T S Features subject to change without notice MODE / CHANNELS VALUES FUNCTION 13CH 22CH 39CH 43CH 196CH 200CH 208CH 211CH Dimmer Fine 000-255 16 bit fine adjustment Dim Modes 000-020 Default to Unit Setting 021-040 Standard 041-060...
Page 25
D M X T R A I T S Features subject to change without notice MODE / CHANNELS VALUES FUNCTION 13CH 22CH 39CH 43CH 196CH 200CH 208CH 211CH Internal Programs RGB (continued) 110-119 Program 11 120-129 Program 12 130-139 Program 13 140-149 Program 14 150-159...
Page 26
D M X T R A I T S Features subject to change without notice MODE / CHANNELS VALUES FUNCTION 13CH 22CH 39CH 43CH 196CH 200CH 208CH 211CH Special Functions No Function (Default LED 000-010 Refresh Rate = 1200 Hz) 900 Hz 910 Hz 920 Hz...
Page 27
D M X T R A I T S Features subject to change without notice MODE / CHANNELS VALUES FUNCTION 13CH 22CH 39CH 43CH 196CH 200CH 208CH 211CH Special Functions (continued) 1360 Hz 1370 Hz 1380 Hz 1390 Hz 1400 Hz 1410 Hz 1420 Hz 1430 Hz...
P I X E L Z O N E S In both images below, the unit is viewed from the front, with the display screen on the rear panel oriented upright. Individual RGB pixels are designated with numbers from 1 to 64. RGB pixel 1 is located at the left edge of the top face of the unit, and successive RGB pixels progress around the unit in a clockwise direction until reaching RGB pixel 64.
R G B M A C R O S MACRO DMX VALUES GREEN BLUE R02 Bastard Amber 001-007 R04 Medium Amber 008-015 R09 Pale Amber Gold 016-023 R316 Gallo Gold 024-031 R21 Golden Amber 032-039 R26 Light Red 040-047 R27 Medium Red 048-055 R36 Medium Pink 056-063...
C O L O R T E M P E R A T U R E T A B L E Colors shown are an approximate representation. https://www.luxalight.eu/en/cie-convertor DMX VALUE COLOR TEMPERATURE (K) DMX VALUE COLOR TEMPERATURE (K) 2300 6200 2400 6300 2500...
D I M M O D E S A N D C U R V E S DIMMER DIMMER 100% 100% Time (ms) Time (ms) Rise Time Down Time 0 Sec 0 Sec Rise Time Down Time 0 sec Fade Time 1 sec Fade Time 0 sec Fade Time 1 sec Fade Time...
P R I M A R Y - S E C O N D A R Y S E T U P This function allows you to link units together to run in a Primary-Secondary set-up, in which one unit will act as the controlling unit and the others will react to the controlling unit’s built-in programs.
Regular inspections are recommended to ensure proper function and extended life. There are no user serviceable parts inside this fixture. Please refer all other service issues to an authorized ADJ service technician. Should you need any spare parts, please order genuine parts from your local ADJ dealer.
Remove the fuse and replace with a fresh fuse. Always use a fuse of the same 3AL / 250V rating for replacement. Fuse O R D E R I N G I N F O R M A T I O N SKU (US) SKU (EU) DESCRIPTION VIN004 1226100440 Vintage X...
(1) IP65 Locking Power Cable • Safety Eyelet • Digital Display Optional Accessories: • Coffin Lock System to Interlock up to 8 Vintage X • Omega Clamp (107mm) units • Adjustable Hanging Bracket • Omega Clamp Receivers (Omega Clamp Sold...
F C C S TAT E M E N T Please note that changes or modifications to this product that have not been expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
Need help?
Do you have a question about the VINTAGE X and is the answer not in the manual?