(12) months from date of installation or eighteen (18) months from date of delivery, which- ever expires first, and (b) SPX FLOW services are warranted to Buyer to have been performed in a workman- like manner for a period of ninety (90) days from the date of performance. If the goods or services do not conform to the warranty stated above, then as Buyer’s sole remedy, SPX FLOW shall, at SPX FLOW’s option,...
Page 7
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Warranty This page intentionally left blank. 01/2025 95-03109 Page 4...
READ AND UNDERSTAND THIS MANUAL PRIOR TO INSTALLING, OPERATING, OR SERVICING THIS EQUIPMENT SPX FLOW recommends users of our equipment and designs follow the latest Industrial Safety Standards. At a minimum, these should include the industrial safety requirements established by: 1.
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Safety Warnings Read the instructions before installing the pump and starting it up. Always follow the guidelines for assembly in order to achieve optimum operational reliability. Always check that the specifications of the motor and the motor control unit are correct, particularly in operating environments where there may be a risk of explosion.
The following labels are installed on your equipment. If these labels are removed or become unreadable, contact SPX FLOW customer service at 1-800-252-5200 or 262-728-1900, and refer to the part numbers below for replacement labels. See also items 65 and 66 in the parts list section starting on page 67.
Brand Universal 2 ND Pump Care of Component Materials Care of Component Materials NOTE: SPX FLOW recommends the use of an anti-seize compound on all threaded connections. Failure to comply with the Care of Component Materials could lead to bodily injury. Stainless Steel Corrosion Corrosion resistance is greatest when a layer of oxide film is formed on the surface of stainless steel.
Any use exceeding the margins and specifications set forth is considered to be not intended. SPX FLOW is not liable for any damage resulting from such activities. The user bears the full risk. Improper use of the pump leads to:...
300 psi (20.7 bar) 208 gpm (47.2 m /hr.) .752 gal (2.847 liter) 4.25 x 12.70 6" 300 psi (20.7 bar) 300 gpm (68.1 m /hr.) Other inlet/outlet sizes are available. Contact SPX FLOW Application Engineering. 01/2025 95-03109 Page 10...
Page 14
Hot and Extra Hot Clearance -40°F (-40°C) to 300°F (149°C) * Contact SPX FLOW Application Engineering for higher pressures or higher temperature applications. Operating the pump outside the stated operating parameters may result in severe personal injury or death. Page 11...
Some models in some series have a "316SS Hot" clearance rotor option for temperatures above 200°F (93°C). NOTE: Consult SPX FLOW Technical Services for applications near 300°F or above 200°F with 316SS rotors. "Extra Hot" clearance rotors are recommended for use with products such as chocolate, which tend to "plate out"...
® Introduction Waukesha Cherry-Burrell Brand Universal 2 ND Pump Qualification Guidelines for Operating Staff Definitions Operator A person who is capable of handling the installation, interior, operation, warnings, cleaning, repair or transpor- tation of the machine. Trained person A person who is instructed in the tasks given and the possible dangerous situation that may occur. The person is also aware of the protection installations and measures.
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Transportation/ Installation Transportation/ Installation Transportation Handling • Use appropriate lifting equipment to handle the pump. Ensure the lifting equipment is rated for the weight of the pump. • Avoid sudden impacts or jolts during handling to prevent damage to the pump components.
Do not lift by the eye bolts on the pump or motor. Due to the wide range of pump sizes and motors, SPX FLOW cannot give lifting instructions here for all configurations. Contact SPX FLOW or an authorized lifting expert if questions arise. Page 15...
Guards are provided as part of a complete pump and drive package and are selected by SPX FLOW Engineering for the pump, base, and motor ordered. Do not modify the guard provided by SPX FLOW. If the guard provided by SPX FLOW is Figure 6 - Permanent Installation on Foundation...
® Transportation/ Installation Waukesha Cherry-Burrell Brand Universal 2 ND Pump Install Connections and Piping Piping Support To minimize forces exerted on the pump, support all piping to the pump independently with hangers or pedestals. Such forces can cause misalignment of the pump parts and lead to excessive wear of rotors, bearings, and shafts.
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Transportation/ Installation Install Check Valves Inlet Side on Lift Applications Use check valves to keep the inlet line full, particularly with low- viscosity fluids (Figure 11). A. Inlet Check Valve B. Foot Check Valve Figure 11 - Inlet Check Valve Discharge Side For systems with liquid under a vacuum, install a check valve on...
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Transportation/ Installation Inlet Side Strainers and Traps Inlet side strainers and traps (Figure 17, items A and B, respec- tively) can be used to prevent foreign matter from damaging the pump. Select carefully to prevent cavitation caused by restricting the inlet.
15 min- bypass may be used. To determine the appropriate bypass utes for the pump fluid components to arrangement, contact SPX FLOW Application Engineering. thermally expand, then re-start the • Ensure that a differential pressure is created across the pump.
Periodic re-checking is advisable during the pump service life. • SPX FLOW recommends using a flexible coupling to connect the drive to the pump. Several different types are available, including couplings with slip or overload provisions. SPX ®...
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Transportation/ Installation Check Belt and Chain Use a straight edge to visually check the belt or chain alignment. Drive Alignment Keep the shaft distance to a minimum (Figure 25, item A). After the piping is complete and before the belts are installed, manually turn the pump shaft to ensure it turns freely.
® Transportation/ Installation Waukesha Cherry-Burrell Brand Universal 2 ND Pump Check Pump Rotation After the correct drive rotation is verified, connect the coupling and assemble the pump and coupling guards. NOTE: The pump is bidirectional unless it is supplied with optional suction vents.
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Operation Operation The pump contains internal moving These pumps are positive displacement, low slip design and will parts. DO NOT put hands or fingers into be severely damaged if operated with closed valves in the the pump body ports or drive area at any discharge or inlet lines.
® Maintenance Waukesha Cherry-Burrell Brand Universal 2 ND Pump Maintenance Important Safety Maintenance should be performed only by trained personnel. See Information “Qualification Guidelines for Operating Staff” on page 13. The pump contains internal moving Make sure the pump is securely bolted or clamped down prior to parts.
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Maintenance Lubrication Drive Lubrication Refer to the manufacturer’s manual shipped with the drive for proper drive lubrication and frequency. Gears Gears are factory-lubricated with gear oil at the quantity shown in Table 3. Change the oil every 750 hours. NOTE: Aggressive washdown or extreme running conditions may require more frequent lubrication intervals.
® Maintenance Waukesha Cherry-Burrell Brand Universal 2 ND Pump Maintenance Inspections The pump contains internal moving parts. DO NOT put hands or fingers into the pump body ports or drive area at any time during operation. To avoid serious injury, DO NOT install, clean, service, or repair the pump unless all power is off and locked out.
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Maintenance Inspection of Gears and Bearings Gear backlash With the fluid head and seals removed, feel for gear backlash by rotating either shaft by hand. The other shaft must engage imme- diately. Perform this check three times at 60-degree intervals. If play (backlash) is evident, remove the gear case cover, check the gear teeth for wear, and ensure that the gear is not loose on the shaft.
® Maintenance Waukesha Cherry-Burrell Brand Universal 2 ND Pump Maintenance Inspection Chart Frequency Check for Possible Causes Possible Solutions At least Low oil level, oil Oil leak from gear case cover oil Replace oil seals (items 12 & 13 in the weekly contamination, seal or gear case rear oil seal...
NOTE: Always replace the rotor nut O-rings and rotor hub O- rings when reassembling the pump. If the area behind these seals becomes soiled, contact SPX FLOW Application Engineer- ing for a specific cleaning and sanitizing procedure validated to remove bacteria. If a chlorine solution (200 ppm available chlo- rine) is used, it should leave no residual deposits which would remain in the pump.
® Maintenance Waukesha Cherry-Burrell Brand Universal 2 ND Pump Fluid Head Disassembly The pump contains internal moving parts. DO NOT put hands or fingers into the pump body ports or drive area at any time during operation. To avoid serious injury, DO NOT install, clean, service, or repair the pump unless all power is off and locked out.
Page 37
2-1/4" 139797+ 210, 214, 320, 324 2-3/8" 126536+ NOTE: SPX FLOW recommends using the Non-Marring Socket Tool for Rotor Nuts to protect the rotor nut. See Table 5 above and page 121. Figure 35 - Loosen Bottom Rotor Remove Rotors 1.
Page 38
® Maintenance Waukesha Cherry-Burrell Brand Universal 2 ND Pump Remove Pump Body 1. Remove the two body retaining cap screws (Figure 37, item 45). 2. Using a plastic mallet, tap the body off the gear case, dowel pins and body studs. 3.
Page 39
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Maintenance 3. Inspect the three seal body pins for damage and repair or replace them as necessary. If the pins are loose, replace them with new ones. 4. Remove the rotary seal from each shaft. Use caution not to damage the seals during removal.
® Maintenance Waukesha Cherry-Burrell Brand Universal 2 ND Pump Gear Case Disassembly To avoid serious injury, DO NOT install, To avoid serious injury, shut off and drain product from the pump clean, service, or repair the pump unless prior to disconnecting piping. all power is off and locked out.
“off-the-shelf” bearings can be many times larger than required. Although they are considered in-spec in the bearing industry, they can cause internal damage within an SPX FLOW PD Pump. SPX FLOW’s proprietary bearing “MATCHING” process starts with top quality bearing assemblies, then sorts, measures, pairs, grinds and adds spacers to them to ensure the matched bearing sets meet the required tight internal tolerances.
Page 43
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Maintenance NOTE: The following instructions cover the assembly of a six- piece front bearing assembly. For a four-piece assembly, only one spacer and cup is used. 1. Lubricate the front bearing area of the shaft (Figure 47, item 7, 8) with oil or grease.
® Maintenance Waukesha Cherry-Burrell Brand Universal 2 ND Pump 7. Place the upper cup (Figure 51, item E) on top of the outer spacer. 8. Lubricate the remaining upper cone and roller assembly (Figure 51, item F) with oil or grease and slip it over the shaft with the roller radius facing up.
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Maintenance Gear Case Assembly Shimming 1. When installing the shafts in the gear case, shim behind the front bearing to achieve the proper backface clearance between the back of the rotors and the body. The backface To lift the gear case assembly on pumps clearance must be equal for both rotors to prevent the rotors larger than 015-U2 ND, attach lifting...
14. If the rotor to body clearance is not met or is uneven, contact SPX FLOW Application Engineering for proper adjustment procedures. 15. After obtaining proper clearance, remove the rotor nuts, rotors, body, and bearing retainers.
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Maintenance 16. Grease the front and rear bearing through the grease fittings until grease is visible around the bearing assemblies. The amount of grease required is listed in “Grease Quantity (per Bearing)” on page 28. Rotate the shafts while greasing to disperse the grease.
® Maintenance Waukesha Cherry-Burrell Brand Universal 2 ND Pump Install Timing Gears 1. Place the gear keys into the shaft key slots. Angle the keys out for easier installation of the gears. NOTE: To aid in timing setup, rotate the rotors until they are at right angles to each other before installing the gears.
Page 49
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Maintenance NOTE: It is generally best to keep 1. To check backface clearance, first mount the body (less backface clearance to a minimum. seals) onto the housing. Assemble the rotors and secure them with rotor jam nuts.
NOTE: If the clearance corrections in Table 9 have been performed and desired performance is not achieved, contact SPX FLOW technical services for guidance. Install Gear Case Cover 1. Lubricate the inside diameter of a new oil seal (3).
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Maintenance Fluid Head Assembly Install Mechanical Seal Single Mechanical seal Double Mechanical seal 37. Stop Pin 95. Inner Wave Spring 91. Inner Seal O-ring 96. Outer Seal O-ring 92. Shaft O-ring 97. Outer Wave Spring 93.
Page 52
® Maintenance Waukesha Cherry-Burrell Brand Universal 2 ND Pump 6. Place the inner seal into the back of the pump body. Ensure that the notches are aligned in the inner seal with the stop pins in the body. Press firmly and evenly into place. 7.
Page 53
NOTE: Always block the rotor against the body, not against the other rotor. NOTE: SPX FLOW recommends using the Non-Marring Socket Tool for Rotor Nuts to protect the rotor nut when torquing. 7. Screw the rotor nuts (item 26) onto the shafts (clockwise) and tighten them to the required torque.
Page 54
® Maintenance Waukesha Cherry-Burrell Brand Universal 2 ND Pump Table 10: Rotor Nut Wrench Size and Socket Tool Use a torque wrench to tighten the rotor nuts to the proper torque. Wrench Socket U2 ND Model (See Tables 10 and 11 for wrench sizes and torque values.) Size Tool Failure to tighten the nuts properly could result in the nuts...
Page 55
Continued pump operation with the entire flow by-passing will rapidly build heat within the pump body. Con- tact SPX FLOW Application Engineering for assistance. Figure 73 - Manual Cover NOTE: The vented cover is not CIP-able. It must be manually disassembled for cleaning.
® Maintenance Waukesha Cherry-Burrell Brand Universal 2 ND Pump Installation Adjustment Manual Turn the adjusting screw counterclockwise to its farthest position, then clockwise until a light spring pressure is felt. Pneumatic Diaphragm 1. Set air/gas pressure to 2-5 psig. 2. Turn on the pump. 3.
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Maintenance Jacketed Cover The jacketed cover is designed to allow circulation of a heating or cooling medium. The purpose is to help preheat or cool the pumping head and sustain operating temperature during short shutdown periods.
Page 58
® Maintenance Waukesha Cherry-Burrell Brand Universal 2 ND Pump 3. Remove and inspect the Jacketed cover gasket (36C). Figure 80 - Remove Gasket Jacketed Cover Assembly 1. Install the Jacketed cover gasket (36C) into the groove on the Jacketed cover. NOTE: Press on hump with fingers firmly and evenly into place.
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Maintenance Low Pressure Flush Model Pipe Tap O-ring 1. Set flow rate of approximately 1/4 GPM for most applications. Number For high temperature applications, increase flow. (See “If the 3/4 NPT V70252 pumped product contains abrasive solids or hardens on the 006 - 018 seal faces, an alternate high pressure barrier flush...
Page 60
® Maintenance Waukesha Cherry-Burrell Brand Universal 2 ND Pump 2. Remove all the retainer-tab bolts (72) and retainer-tabs (71) from the pump body, as shown in Figure 84. This is applicable for model 180-370. Figure 84 - Remove Screws and Retainer-tab 3.
Page 61
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Maintenance Install Lip Seal 1. Lubricate the two sleeve O-rings (78) with a lubrication com- pound compatible with the O-ring material and process fluid(s). Install the sleeve O-rings (78) into the groove of the sleeve (74), 2.
Page 62
® Maintenance Waukesha Cherry-Burrell Brand Universal 2 ND Pump Figure 90 - Install Screws and Retainer-tab Install Pump body 1. Install the installation guide (A) on both shafts to avoid dam- aging the lip seals as the pump body is drawn over the shafts. Ensure the front face of installation guide is attached to the back face of sleeve, as shown in Figure 91.
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Troubleshooting Troubleshooting PROBLEM POSSIBLE CAUSE SUGGESTED ACTION No flow, pump rotors are Drive motor not running. Check resets, fuses, circuit breakers. not turning Keys sheared or missing. Replace. Drive belts, power transmission Replace or adjust.
Page 66
Insufficient flow Speed too low or too high to Check flow-speed curve (available from obtain desired flow. SPX FLOW website) and adjust as necessary. Air leak due to bad seals, pipe Replace seals, check inlet fittings. connections, or other equipment.
Page 67
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Troubleshooting PROBLEM POSSIBLE CAUSE SUGGESTED ACTION Noisy operation Cavitation High fluid viscosity. Slow down pump, reduce temperature, High vapor pressure fluid. change system setup. High temperature. Net Inlet Pressure Available Increase NIPA - Net Inlet Pressure less than Net Inlet Pressure Available or reduce NIPR - Net Inlet Required.
Page 68
® Troubleshooting Waukesha Cherry-Burrell Brand Universal 2 ND Pump PROBLEM POSSIBLE CAUSE SUGGESTED ACTION Pump requires excessive Fluid sets in line and pump during Insulate lines or heat trace lines. power (overheats, stalls, shutdown. Install a “soft start” drive. high current draw, breakers trip) Install a recirculating bypass system.
Page 69
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Troubleshooting This page intentionally left blank. 01/2025 95-03109 Page 66...
® Parts List Waukesha Cherry-Burrell Brand Universal 2 ND Pump Parts List 006, 014, 015, 018-U2 ND Pump Parts Jacketed cover Page 67 95-03109 01/2025...
Page 71
Gear Case Assemblies listed are upper drive, side mount left hand, and include shafts and timing gears. CI assemblies are painted WCB blue. Contact customer service for other options. Please contact the SPX Flow Customer Service for Gear Case options. 13. Single wing rotors cannot be used with rectangular flange inlet pumps.
® Parts List Waukesha Cherry-Burrell Brand Universal 2 ND Pump 006, 014, 015, 018-U2 ND Common Parts Jacketed cover Page 69 95-03109 01/2025...
Page 73
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Parts List 006, 014, 015, 018-U2 ND Common Parts QTY. PER ITEM NO. DESCRIPTION PART NO. NOTES PUMP Pump Cover 307625+ Jacketed Cover Pump Cover Vented - Complete Assembly Gear Case Cover, Steel 020106000+ Gear Case Cover, SS;...
Page 74
® Parts List Waukesha Cherry-Burrell Brand Universal 2 ND Pump 006, 014, 015, 018-U2 ND Common Parts, cont’d Jacketed cover Page 71 95-03109 01/2025...
Page 75
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Parts List 006, 014, 015, 018-U2 ND Common Parts, cont’d QTY. PER ITEM NO. DESCRIPTION PART NO. NOTES PUMP 006-014-015-U2 ND Key, Rotor 101817+ 018-U2 ND Key, Rotor 101819+ Shim Kit 117889+ Spacer, Gear to Rear Bearing 015055000+ Bearing Spacer...
Page 76
® Parts List Waukesha Cherry-Burrell Brand Universal 2 ND Pump 030, 034, 040-U2 ND Pump Parts Jacketed cover Page 73 95-03109 01/2025...
Page 77
Gear case assemblies listed are upper drive, side mount left hand, and include shafts and timing gears. CI assemblies are painted WCB blue. Contact customer service for other options. Please contact the SPX Flow Customer Service for Gear Case options. 12. Replaces P/N 104707 (straight) and P/N 104836 (90 degree) rotors.
Gear case assemblies listed are upper drive, side mount left hand, and include shafts and timing gears. CI assemblies are painted WCB blue. Contact customer service for other options. Please contact the SPX Flow Customer Service for Gear Case options. 12. Replaces (obsolete) P/Ns 104728 (straight) and 104857 (90 degree) rotors.
Page 83
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Parts List 045, 060, 064, 130, 134-U2 ND Pump Parts QTY PER ITEM NO. DESCRIPTION PART NO. NOTES PUMP 045-U2 ND Pump Body See Note 1 045-U2 ND Pump Body with Flush See Note 1 060-U2 ND Pump Body See Note 1...
® Parts List Waukesha Cherry-Burrell Brand Universal 2 ND Pump 180, 184, 220, 224-U2 ND Pump Parts Jacketed cover Page 87 95-03109 01/2025...
Page 91
Gear Case Assemblies listed are upper drive, side mount left hand, and include shafts and timing gears. CI assemblies are painted WCB blue. Contact customer service for other options. Please contact the SPX Flow Customer Service for Gear Case options. 12. Replaces (obsolete) P/Ns 104764 (straight) and 104893 (90 degree) rotors.
® Parts List Waukesha Cherry-Burrell Brand Universal 2 ND Pump 180, 184, 220, 224-U2 ND Common Parts Jacketed cover Page 89 95-03109 01/2025...
Page 93
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Parts List 180, 184, 220, 224-U2 ND Common Parts QTY. PER ITEM NO. DESCRIPTION PART NO. NOTES PUMP Pump Cover 307628+ Jacketed Cover Pump Cover Vented - Complete Assembly Gear Case Cover, Steel 230106000+ Gear Case Cover, SS;...
Page 94
® Parts List Waukesha Cherry-Burrell Brand Universal 2 ND Pump 180, 184, 220, 224-U2 ND Common Parts, cont’d Jacketed cover Notes: (See "Notes" column on page 92) * Recommended Spare Parts For pumps purchased before about 1990, replace both spacers, as 40878+ will not work correctly with the old design spacer (200055000).
Page 95
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Parts List 180, 184, 220, 224-U2 ND Common Parts, cont’d ITEM NO. DESCRIPTION QTY. PER PUMP PART NO. NOTES 180-184-U2 ND Key, Rotor 101828+ 220-224-U2 ND Key, Rotor 101827+ Shim Kit 117892+ Spacer, Gear to Rear Bearing 40878+ Bearing Spacer...
Gear case assemblies listed are upper drive, side mount left hand, and include shafts and timing gears. CI assemblies are painted WCB blue. Contact customer service for other options. Please contact the SPX Flow Customer Service for Gear Case options. 12. Replaces (obsolete) P/Ns 107662 (straight) and 107663 (90 degree) rotors.
Page 97
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Parts List 210, 214, 320, 324, 370-U2 ND Pump Parts ITEM NO. DESCRIPTION QTY. PER PUMP PART NO. NOTES 210-U2 ND Pump Body See Note 1 210-U2 ND Pump Body with Flush See Note 1 214-U2 ND Pump Body See Note 1...
® Parts List Waukesha Cherry-Burrell Brand Universal 2 ND Pump Universal 2 ND Standard Seals Figure 93 - Standard Single Mechanical Seal Figure 94 - Standard Double Mechanical Seal Page 101 95-03109 01/2025...
Page 105
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Parts List Universal 2 ND Standard Seals Part No. (by model) Qty. per Pump Item 006, 014, 030, 034, 045, 060,064, 180, 220, 210, 214, Description 015, 040-U2 ND 130, 224-U2 ND 320, 324, Seal Seal...
® Parts List Waukesha Cherry-Burrell Brand Universal 2 ND Pump Universal 2 ND Narrow Face (NF) Seals The Universal 2 Narrow Face (NF) seal is available in the single or double mechanical seal design. The smaller diameter rotating seal seat (item 93) is only used with the SM NF seal. PD100-078b PD100-079a Figure 95 - NF Single Mechanical Seal...
Page 107
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Parts List Universal 2 ND Narrow Face (NF) Seals Part No. (by model) Qty. per Pump Item 006, 014, 045, 060,064, 210, 214, Description 030, 034, 180, 220, 015, 018- U2 130, 134-U2 320, 324, Seal Seal...
® Parts List Waukesha Cherry-Burrell Brand Universal 2 ND Pump Triple Lip Seal Triple Lip Seal components SECTION VIEW Triple Lip Seal components ITEM QTY PER PART NO. PART NO. PART NO. PART NO. PART NO. DESCRIPTION NOTES PUMP 006-015-018 030-040 045-060-130 180-220...
® Parts List Waukesha Cherry-Burrell Brand Universal 2 ND Pump Grease Seals, Bearing Retainers, and Bearing Isolator Kits For pumps manufactured: U2 ND Model Item Description Notes after 7/12/04 before 7/12/04 Number (Newest) 006, 014, Grease Seal, Bearing Retainer, standard 000030018+ 121679+ 015, 018,...
® Parts List Waukesha Cherry-Burrell Brand Universal 2 ND Pump ™ Tru-Fit Universal 2 ND PD Pump PD100-433a OPPOSITE SIDE Page 119 95-03109 01/2025...
Page 123
Depends on the Nord motor, material, paint. Contact customer service with serial number for part number. Item 12, Oil seal, Adapter, is the same seal that is used on non-Tru-Fit pumps. It is not included with item 4A. Please contact the SPX Flow Customer Service for Gear Case options. 01/2025...
® Waukesha Cherry-Burrell Brand Universal 2 ND Pump Long Term Storage Long Term Storage Long-term storage (greater than six months) of Waukesha Cherry-Burrell brand pumps: Before Storage 1. Lubricate all bearings and seals, including: • Rubber o-rings and mechanical seal faces (new pump bearings installed from the factory are already lubricated).
Guards are provided as part of a complete pump and drive package and are selected by SPX FLOW Engineering for the pump, base, and motor ordered. Do not modify the guard provided by SPX FLOW. If the guard provided by SPX FLOW is lost, contact SPX FLOW Customer Service and provide your order number or PO number of the pump to order a correctly-sized replacement guard.
® ATEX Declaration Waukesha Cherry-Burrell Brand Universal 2 ND Pump ATEX Declaration for Universal 2 ND 1. The ATEX Declaration of Conformity must be included with the order. The declaration on the next page is not valid but is supplied for example purposes only. 2.
Please see the certificate received with your order for your serial number. This declaration only provides an example of SPX FLOW’s Declaration. Manufacturer Name SPX Flow US, LLC. Address 611 Sugar Creek Road, Delavan, WI 53115, USA. EU Declaration of Conformity EC Declaration of Conformity...
200°F (93°C); Hot Clearance Rotors: -40°F (-40°C) to 300°F (149°C). Contact SPX FLOW Application Engineering if alternate rotors are needed. NOTE: The assembly clearances stated above are for reference only. Actual pump clearances may vary based on pump performance testing.
200°F (93°C); Hot Clearance Rotors: -40°F (-40°C) to 300°F (149°C). Contact SPX FLOW Application Engineering if alternate rotors are needed. NOTE: The assembly clearances stated above are for reference only. Actual pump clearances may vary based on pump performance testing.
Need help?
Do you have a question about the Waukesha Cherry-Burrell Universal 2 ND Series and is the answer not in the manual?
Questions and answers