Introduction

Table of Contents

1 Introduction
A. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
B. Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
C. Kit Contents of HEAT-OUT-GAS . . . . . . . . . . . . . . . . . . . . 2
D. Installation Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
A. Framing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
B. Installing Vent Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
C. Connecting Insulated Flex Duct . . . . . . . . . . . . . . . . . . . . 13
Installation of the HEAT-OUT-GAS may be done by a
qualified service technician only. Installation MUST com-
ply with local, regional, state and national codes and reg-
ulations.
IMPORTANT:
Failure to read and follow these instruc-
tions may create a possible hazard and will void the fire-
place warranty.
These instructions must remain with the equipment.
1
HEAT-OUT-GAS
- Installation Instructions -
8000C-IFT
8000CL-IFT
8000CLX-IFT
8000CMOD-IFT
CD4842IFTR
CD4842IFTLR
CNXT4842IFTT/H
MERIDPLA36/MERIDPLA42
RAVE32/42-IFT
TRUE-IFT/HEIR-IFT
ESC-42ST-IFT
ECHEL-C
CRAVE-C
RAVE32/36/42-IFT-B
CERONA-36/42-IFT
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Hearth & Home Technologies • HEAT-OUT-GAS Instructions • 2310-939 Rev K • 5/24
NOTICE
• Leave this manual with
party responsible for use
and operation.
CAUTION! Risk of Cuts or Abrasions. Wear protective
gloves and safety glasses during installation. Sheet metal
edges are sharp.
CAUTION! Failure to install, operate, and maintain the
power venting system in accordance with manufacturer's
instructions will result in conditions which may produce
bodily injury and/or property damage.
NOTICE: The fan motors present in the HEAT-OUT-GAS
Heat Management System will generate sound during op-
eration. The effects of the increased sound level can be
minimized with careful planning during installation of the
system.
CAUTION! Risk of Shock! Disconnect electrical power
from fireplace/power vent before performing any mainte-
nance, repair, or electrical wiring.
A. Introduction
The HEAT-OUT-GAS Heat Management system is de-
signed to remove unwanted heat from your home. The
HEAT-OUT-GAS operates on 120VAC, 60Hz electrical
services.
B. Approvals
The HEAT-OUT-GAS kit uses flexible duct marked as meet-
ing requirements of UL-181, Class I ducting.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IntelliFire Touch CNXT4236IFTT/H and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hearth & Home IntelliFire Touch CNXT4236IFTT/H

  • Page 1: Table Of Contents

    HEAT-OUT-GAS - Installation Instructions - For use with these IntelliFire™ Touch models: 6000C-IFT 8000C-IFT 6000CL-IFT 8000CL-IFT 6000CLX-IFT 8000CLX-IFT 6000CMOD-IFT 8000CMOD-IFT CD4236IFTR CD4842IFTR CD4236IFTLR CD4842IFTLR CNXT4236IFTT/H CNXT4842IFTT/H MERID36/MERIDPLA36 MERIDPLA36/MERIDPLA42 COSMO32/42-IFT RAVE32/42-IFT JADE32IN/JADE42IN/JADE42IL TRUE-IFT/HEIR-IFT MARQ36IN/MARQ42IN/MARQ42STIN ESC-42ST-IFT SL-3X/5X/7X/9X-IFT ECHEL-C MEZZO-C CRAVE-C COSMO32/36/42-IFT-B RAVE32/36/42-IFT-B JADE32IN-B/JADE42IN-B/JADE42IL-B CERONA-36/42-IFT NOTICE...
  • Page 2: Kit Contents Of Heat-Out-Gas

    C. Kit Contents of HEAT-OUT-GAS CAUTION! Do not install damaged components. DESCRIPTION SERVICE PART NO. If any parts are missing or damaged, contact your dealer 6 in. Round Duct 659-200 before starting installation. DO NOT install a damaged kit. Fan Base Assembly SRV4086-021 Cover Assembly 4086-022...
  • Page 3: Installation Guidelines

    D. Installation Guidelines The HEAT-OUT-GAS accessory is tested and safe when installed in accordance with this installation manual. It is your responsibility to read all instructions before starting installation and to follow these instructions carefully during installation. Installation of this kit MUST be performed by a qualified service technician.
  • Page 4 HEAT-OUT-GAS Configuration NOTICE: Damper MUST be installed properly or it will not function properly. • Vertical Mounting: Install crimped side up. • Horizontal Mounting: Rotate so the damper closes shut when the HEAT-OUT-GAS kit is not running. IMPORTANT: See appliance installation manual for Heat Management prep and location of approved knockout use specific to each model unit.
  • Page 5 Possible Air Duct Runs/Locations Maximum Duct Run Length: 35 FT. Minimum Duct Run Length: 36 IN. Clearance to flexible duct = 0 Maximum Number of 90 Degree Elbows (Turns) = 6 Figure 1.3 HEAT-OUT-GAS Locations Power Vent Termination Clearances PV = PVLP-SLP HO = HEAT-OUT-GAS 24 IN.
  • Page 6: Framing Dimensions

    Framing A. Framing Chassis Dimensions The dimensions are measured as shown in Figure 2.1. Mounting Hole Locations 10-1/8 in. (258mm) 5-7/8 in. (149mm) 16-3/4 in. 14-1/8 in. (360mm) (425mm) 8-3/4 in. (222mm) 2-3/4 in. (70mm) 7/8 in. (21mm) 13-1/2 in. 11 in.
  • Page 7 Roof Top Termination 1. If the HEAT-OUT-GAS is going to terminate on a flat roof, an enclosure similar to the one shown in Figure 2.3 will need to be constructed. Insulated Flex Duct 12 in. (305 mm) Figure 2.3 Flat Roof Enclosure Hearth &...
  • Page 8: Installing Vent Cap

    B. Installing Vent Cap 1. Remove the four screws holding the shipping bracket to the base of the HEAT-OUT-GAS. See Figure 2.4 and 2.5. 2. Remove the shipping bracket. See Figure 2.6. 3. The HEAT-OUT-GAS base should look like the picture in Figure 2.7.
  • Page 9 If installing with finishing material less than Formed Tabs 1 inch thick go to step 15. Note: A HEAT-OUT-BEK kit will be needed for installations with exterior finishing materials greater than 1 in. thick. Order with the appliance and venting system. It will be used to ensure that the finishing is done to the appropriate size for the HEAT-OUT-GAS to be installed properly.
  • Page 10 13. Apply a bead of silicone (with a minimum of 300° F continuous exposure rating) around the entire metal flange of the HEAT-OUT-GAS. See Figure 2.14. Align with HEAT-OUT-BEK as shown in Figure 2.12. Ensure cap is level and square, then secure HEAT-OUT-GAS to HEAT-OUT-BEK as shown in Figure 2.13.
  • Page 11 17. Once the cap is fastened to the wall, remove the junc- 20. Reinstall the junction box cover. See Figure 2.16. tion box cover to wire the Heat-Out. See Figure 2.16. 21. Install the decorative front cover onto the Heat-Out 18.
  • Page 12 Figure 2.19 22. Once the decorative front cover is installed, apply a bead of silicone (with a minimum of 300°F continuous exposure rating) between the decorative cover and the finishing material around the cap. See Figure 2.20. Figure 2.20 23. If the HEAT-OUT-GAS is being installed on a building with vinyl siding, the vinyl siding shield needs to be installed using three #8 x 1/2 Phillips screws.
  • Page 13: Connecting Insulated Flex Duct

    C. Connecting Insulated Flex Duct Connections Splices 1. Fold back jacket and insulation from core. Butt 2 cores 1. After desired length is determined, cut completely together on a standard 4" [100 mm] length metal sleeve. around or through duct with knife or scissors. Cut wire with wire cutters.
  • Page 14: Electrical Information

    Electrical Information A. Wiring the Appliance for the HEAT-OUT- Note: The process of pairing the IntelliFire™ Touch remote control with the appliance will need to be NOTICE: Electrical wiring must be done in accordance performed at this time in order for the HEAT-OUT- with national, provincial, and/or local electric codes.
  • Page 15 110 VOLTS - AC POWER SUPPLY GROUND BLACK WHITE WALL BOX CONTROL GREEN COVER PLATE BLACK WHITE To heat-out junction box assembly Figure 3.2 Wiring Diagram for Appliances Equipped with Convection Fan Hearth & Home Technologies • HEAT-OUT-GAS Instructions • 2310-939 Rev K • 5/24...
  • Page 16 From fan outlet on ACM or variable wall Rheostat White (neutral) depending on installation Ground Black (hot) Capacitor Terminal Block Blue Brown Black Green/Yellow Blower Figure 3.3 Wiring Diagram (HEAT-OUT-GAS) Please contact your Hearth & Home Technologies dealer with any questions or concerns. For the location of your nearest Hearth &...