Sentera Controls RXT Mounting And Operating Instructions

Room temperature transmitter / switch

Advertisement

Quick Links

RXT
Mounting and operating instructions
ROOM TEMPERATURE
TRANSMITTER / SWITCH

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RXT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sentera Controls RXT

  • Page 1 ROOM TEMPERATURE TRANSMITTER / SWITCH Mounting and operating instructions...
  • Page 2: Table Of Contents

    STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS MOUNTING & OPERATING INSTRUCTIONS IN STEPS MODBUS REGISTER MAPS VERIFICATION OF INSTALLATION INSTRUCTIONS TRANSPORT AND STOCK KEEPING INFORMATION WARRANTY INFORMATION AND RESTRICTIONS MAINTENANCE MIW-RXT-EN-001 - 20 / 11 / 2015 2 - 10 www.sentera.eu...
  • Page 3: Safety And Precautions

    In case there are any questions that are not answered, please contact your technical support or consult a professional. MIW-RXT-EN-001 - 20 / 11 / 2015 3 - 10 www.sentera.eu back to the table of contents...
  • Page 4: Product Description

    ROOM TEMPERATURE TRANSMITTER / SWITCH PRODUCT DESCRIPTION The RXT is a combined room temperature transmitter  /  switch. It provides four pre-defined ranges, one user-definable range, Modbus RTU (RS485) communication, an analogue output and a relay output. ARTICLE CODES Code Supply...
  • Page 5: Operational Diagrams

    Modbus RTU (RS485) signal /B Analogue output (0—10 VDC / 0—20 mA) Ground Normally open contact COM1 Common contact Normally closed contact Connections Cable cross section: max. 1,5 mm MIW-RXT-EN-001 - 20 / 11 / 2015 5 - 10 www.sentera.eu back to the table of contents...
  • Page 6: Mounting & Operating Instructions In Steps

    ROOM TEMPERATURE TRANSMITTER / SWITCH MOUNTING & OPERATING INSTRUCTIONS IN STEPS Before you start mounting the RXT transmitter / switch, read carefully “Safety and Precautions”. Choose a smooth surface for an installation location (a wall, panel and etc.). Open the white cover by releasing the locking plates on both sides of the cover and remove it.
  • Page 7 Fig. 6 Analogue output selection jumper Fig. 7 Sensor range selection jumper 0—20 mA 0—10 VDC 0—30 °C 10—40 °C 20—50 °C 0—50 °C MIW-RXT-EN-001 - 20 / 11 / 2015 7 - 10 www.sentera.eu back to the table of contents...
  • Page 8 Customise the factory settings to the desired ones, through 3SModbus software (if necessary). For the default factory setting see Table Modbus register maps. MIW-RXT-EN-001 - 20 / 11 / 2015 8 - 10 www.sentera.eu back to the table of contents...
  • Page 9: Modbus Register Maps

    100 % value to 1. 22-30 Reserved, returns 0 If you want to find out more about Modbus over serial line, please visit: http://www.modbus.org/docs/Modbus_over_serial_line_V1_02.pdf MIW-RXT-EN-001 - 20 / 11 / 2015 9 - 10 www.sentera.eu back to the table of contents...
  • Page 10: Verification Of Installation Instructions

    In case of heavy pollution, clean with a non-aggressive product. In these circumstances the unit should be disconnected from the supply. Pay attention that no fluids enter the unit. Only reconnect it to the supply when it is completely dry. MIW-RXT-EN-001 - 20 / 11 / 2015 10 - 10 www.sentera.eu...