Circuit Connection - Haier HR-SC Operating Instructions Manual

Solar station
Table of Contents

Advertisement

Installation introduction

Circuit connection

Screw off bolts on the bottom shell of solar station, open its front shell and connect the circuit
as shown in the diagram.
Circuit connection of water storage tank
The nominal cross-sectional area of the wires shall not less than 1.5mm
Conductors identified by the colour combination green/yellow shall only be
Notice
used for grounding conductors
The wires shall provide non-detachable lining or non-detachable bushing.
The wires shall be protected so that they do not come into contact with burrs,
cooling fins or similar edges which may cause damage to their insulation.
The wires shall be protected so that they do not come into contact with hot
surface, wet, or significant amounts of ultraviolet radiation except the wires are
suitable for the conditions.
1
Connect respectively L end (brown) and N end (blue) of wire of water storage tank with L
end and N end of relay. ( N label of relay represents the N electrode of power)
2
Connect temperature sensor of water storage tank with corresponding interface on the
power plate. Insert properly.
3
Fix the grounding wire of water storage tank on the grounding plate of solar station with
grounding bolts.
4
Disassemble wire clamp and fix and press wire connection of water storage tank.
Solar collector
sensor interface
Water storage tank
sensor interface
Signal wire interface
of Display board
Creepage detection
coil interface
Clamp for holding
the wire
Earth plate
Schematic diagram of power
board interface of solar station.
6
Haier solar station
2
.
Relay output
L end
Wire interface
of water pump
Relay output
N end
Relay output
N label

Advertisement

Table of Contents
loading

Table of Contents