Yuwell YE650ARS User Manual
Yuwell YE650ARS User Manual

Yuwell YE650ARS User Manual

Electronic blood pressure monitor

Advertisement

Quick Links

JIANGSU YUYUE MEDICAL EQUIPMENT & SUPPLY CO.,LTD.
NO.1 Baisheng Road Development Zone, Danyang, Jiangsu 212300 CHINA
www.yuwell.com
Tell: +86-0511-86900833
Date of
issue
:2023.12
YY-BPM0088D-01(A/0)
YE650ARS
Electronic Blood Pressure Monitor
User's Manual
Please read the user's manual closely before using!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the YE650ARS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Yuwell YE650ARS

  • Page 1 YE650ARS Electronic Blood Pressure Monitor User's Manual JIANGSU YUYUE MEDICAL EQUIPMENT & SUPPLY CO.,LTD. NO.1 Baisheng Road Development Zone, Danyang, Jiangsu 212300 CHINA www.yuwell.com Tell: +86-0511-86900833 YY-BPM0088D-01(A/0) Please read the user's manual closely before using! Date of issue :2023.12...
  • Page 2: Table Of Contents

    Product Features Contents Bluetooth icon is only applicable to the model Before using with bluetooth function. Product features............. Voice function Operation guide............Product structure and parts......... Cautions..............Important notes............. Battery charging ............Time and date setting..........Voice volume and unit setting....
  • Page 3: Operation Guide

    Operation guide Operation guide 2 Measuring posture This device uses the oscillometric method of blood pressure measurement。 Sit straightly, keep the center of cuff and heart at Please follow the steps as shown below. the same level. (Please turn to page 17 for details.) Power-on Connect the power source for charging as shown...
  • Page 4: Product Structure And Parts

    US Model: HT-C38B-0510WW Power adapter socket reset hole 2. Cuff 4. Display There are 6 types of cuff provided by yuwell. Bluetooth icon Time and date Please subject to the received type. Bluetooth icon is only applicable to the model Battery power icon with bluetooth function.
  • Page 5: Cautions

    Important notes Cautions Statement:The device is a medical device. Pay attention with the symbols shown here to 1. Intended purpose prevent harm or damage to the user. This product is intended to measure the blood Caution pressure and pulse rate of adult who is more than 12 years old at household or medical center (not Type BF applied part suitable for neonate, pregnancy or pre-eclampsia).
  • Page 6 Important notes Important notes Please start again if cannot measure. Avoid compression or bending of the cuff connection For patient of arrhythmia, arterial sclerosis, poor tubing while using the device. Otherwise the perfusion, diabetes, pergnancy, pre-eclampsia, renal measurement results will be inaccurate. diseases, patient motion, trembling, shivering, Warning: Do not tangle the connection tubing,...
  • Page 7: Battery Charging

    If you want your blood pressure measurements to be sent to your phone via Bluetooth, get a phone that supports Android 5.0 and above or IOS 9.0 and above to download Yuwell HealthCare+. Note: This section applies only to the model with bluetooth function.
  • Page 8: Time And Date Setting

    Time and date setting Tips! The monitor will store the measuring results Please use only the authorized Yuwell AC Adapter automatically by the management system. It is (output DC 5V 1A) to charge, and you can contact necessary to reset time and date after charging the local dealer for consultation about the relevant and starting up again.
  • Page 9: Voice Volume And Unit Setting

    Voice volume and unit setting Using method of cuff Voice volume setting Tips! After finishing the time and date setting, press Either of the upper-arms can be measured. Do not the【 START|STOP】 button to enter the voice measure other parts of the body. volume setting.
  • Page 10: Using Method Of Cuff

    Using method of cuff Measuring posture Stick the cuff tightly. Keep the upper arm Note: The cuff should be wearing comfortably, bareness or wearing thin clothes avoiding too tight or loose. Keep the center of cuff and heart at the same level Sit straight and flat the arm on table with palm up, also keep the center of cuff and heart at The ideally height...
  • Page 11: Start Measuring

    Start measuring Start measuring high- 2. Measurement finished Don't eat, smoke, drink, take bath or do any intensity sport within an hour before measuring. After measurement, the monitor will show the SYS, Measurements shall be taken at the same time pulse rate, then...
  • Page 12: Blood Pressure Range Indicator

    Start measuring Blood pressure range indicator 3. Take off the cuff If the SYS is higher than 139mmHg or DIA higher than 89mmHg means having high blood 4. Shut down pressure, please contact with doctor for advice. Press the【START|STOP】button to shut down. Also it will power off automatically in 3 minutes If unexpected readings are obtained, please without any operation.
  • Page 13: Memory Function

    Memory function Memory function Tips! C. Read the recorded data by pressing the【 】 button as the sequence: "01", "02" .."60" (max). The monitor will store the measurement data Then return to the 1st. Holding the【 】button automatically (including blood pressure and pulse), to search the data quickly.
  • Page 14: Auxiliary Measuring Function

    Auxiliary measuring function Static mode This function is mainly for professional personnel to Detection for cuff wearing enter the static mode to test the monitor through The icon " " appears when the cuff is wrapped standard pressure gauge. correctly, and the icon " "...
  • Page 15: Common Questions Of Blood Pressure Measurement

    Static mode Common question of blood pressure measurement 1. What is blood pressure? Note:When the measured pressure Blood pressure is the force exerted by blood exceeds 300mmHg during static test, against the walls of the arteries. Systolic pressure pressure value and " "...
  • Page 16 Common question of blood pressure Common question of blood pressure measurement measurement 4. WHO Blood Pressure Classification? 5. Blood pressure variations? Standards to assess high blood pressure, without An individual's blood pressure varies greatly on a regard to age, have been established by the world daily and seasonal basis.
  • Page 17: Common Fault And Trouble Shooting

    Common fault and trouble shooting Common fault and trouble shooting The table below shows the possible fault Common fault Solutions displaying icon, possible reason, and solutions. It doesn't work after pressing the 【START|STOP】 Please try again after charging button Wrong Fault cause Solution indication...
  • Page 18: Alarm System

    Alarm system Maintenance Please observe the following items to protect the When the determined blood pressure is outside device and ensure the accuracy of measurement. the rated range, there is a visual alarm signal on Please store the monitor and accessories properly the display screen.
  • Page 19: Features And Technical Parameters

    Features and technical Parameters Features and technical Parameters 1. Features Suitable upper-arm circumference: 22-32cm or 22-45cm (optional) Detection for cuff wearing Dimension: Approx.127x92x68 (mm) Indication for irregular heartbeats Weight: about 306g Indication for Movement Error 60 groups of memory 3. Operation and storage conditions Average value display of three times measurement Operation conditions: 2.
  • Page 20: Electromagnetic Compatibility Information

    Electromagnetic compatibility information Features and technical Parameters Essential performance: The contact materials detail of product 1. Limits of the error of the manometer: Air plug Over the temperature range of 5℃ to 40℃ and the Part Rear Cover Top Cover Cuff Air tube connect...
  • Page 21 The customer WARNING: Use of accessories and cables other or the user of the YE650ARS Electronic Blood Pressure Monitor than those specified or provided by the should assure that it is used in such an environment.
  • Page 22 Service frequency Modulation the electromagnetic environment specified below. The customer or the LEVEL (MHz) (MHz) user of the YE650ARS Electronic Blood Pressure Monitor should (V/m) assure that it is used in such an environment. Pulse 380 to 390 TETRA 400...
  • Page 23 Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates,uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.

Table of Contents