Advertisement

Quick Links

Shanghai International Holding Corp.GmbH(Europe)
Eiffestrasse 80,20537 Hamburg Germany
JIANGSU YUYUE MEDICAL EQUIPMENT & SUPPLY CO.,LTD.
Yunyang Industrial Park 212300 Danyang jiangsu
PEOPLE'S REPUBLIC OF CHINA
http://www.yuwell.com
Tell: +86-0511-86900833
Date of
issue
:2021.05
W1 、W10S、W10T、W10F
Electronic Blood Pressure Monitor
User's Manual
1630207-0A
Please read the user's manual closely before using!
SYS
mmHg
DIA
mmHg
P
/min
0
m

Advertisement

Table of Contents
loading

Summary of Contents for Yuwell W10

  • Page 1 Shanghai International Holding Corp.GmbH(Europe) W1 、W10S、W10T、W10F Eiffestrasse 80,20537 Hamburg Germany JIANGSU YUYUE MEDICAL EQUIPMENT & SUPPLY CO.,LTD. Electronic Blood Pressure Monitor Yunyang Industrial Park 212300 Danyang jiangsu PEOPLE'S REPUBLIC OF CHINA http://www.yuwell.com User's Manual Tell: +86-0511-86900833 Date of issue :2021.05 1630207-0A...
  • Page 2: Table Of Contents

    Contents Cautions ……………………………………………………01 Using method Important notes…………………………………………02 Wear the monitor on the wrist as the following picture. Maintenance ………………………………………………05 The suitable circumference for wrist is 13.5cm~19.5cm. Parts ………………………………………………………06 Product charging …………………………………………08 Time and date setting ……………………………………10 Voice and unit setting……………………………………11 Using method of cuff ……………………………………12 Measuring posture Measuring posture ………………………………………13...
  • Page 3: Cautions

    Cautions Important notes Pay attention with the symbols shown here to prevent harm or damage to the user. Statement:the device is a medical device. Attention Note on important information 1. Range of application Type BF application part This product is intended to measure the blood pressure and pulse rate of adult whom more than 12 years old at household or medical center (not Follow instructions for use suitable for neonate, pregnancy or pre-eclampsia.)
  • Page 4 Important notes Important notes Please turn off the device and unplug the adapter before cleaning. It will affect the measurement accuracy if the wrist circumference is out The AC adapter cable may cause accidental strangulation in infants. of the given value. Please pay attention to product storage to prevent damage caused by pets, Do not measure continuously.
  • Page 5: Maintenance

    Parts Maintenance Please observe the following items to protect the device and ensure the 1. Main part accuracy of measurement. Bluetooth icons is only Please store the monitor and accessories properly after use. applicable to the model with bluetooth function. Do not place the monitor and accessories in high temperature, moisture, Memory button dust, or exposure to sunshine.
  • Page 6: Product Charging

    Note: Please charge the device in a position where it is easy to disconnect Us er's manual、Warranty card from supply mains. Tips! Please use only the authorized yuwell AC Adapter (output DC 5V 1A) to charge, and you can contact the local dealer for consultation about the relevant information.
  • Page 7: Time And Date Setting

    Product charging Time and date setting Tips! Time and date setting Do not place equipment with lithium batteries near the fire source. The monitor will store the measuring results automatically by the management system. Do not remove and replace the battery or squeeze the battery with It is necessary to reset time and date after installing new batteries.
  • Page 8: Voice And Unit Setting

    Voice and unit setting Using method of cuff Please wear the cuff on bare wrist not too loose or too tight, do not leave Voice volume setting cloth inside of the cuff. Tips! This section applies only to models with voice function. 2.
  • Page 9: Measuring Posture

    Measuring posture Measuring posture The correct wrist posture(as Figure 2) 1. Sit straightly and keep relax. (as Figure 1) Do not bend down or body bend forward. 2. Take 3~4 deeply breath then relax shoulder and arm before measurement. 13.5-19.5cm 3.
  • Page 10: Start Measuring

    Start measuring Start measuring 1. Do not move and keep quiet until measurement finished. 2. Keep the monitor and heart at the same level. 3. Restart if the cuff got loose while measurement. mmHg 4. Press the " " button to stop measurement. If it does not work, mmHg please take off the cuff.
  • Page 11 Start measuring Start measuring Please maintain the position during the measurement and don't speak or Please contact with doctor for advice if the SYS is higher than 139mmHg move body or hand. or DIA is higher than 89mmHg. Also the blood pressure range indicator can show the blood pressure intuitively.
  • Page 12: Memory Function

    Memory function Memory function 1. Press the " " button for the records. The 74th data may be replaced by the 73rd when the memory Tips! A. Press the " " button to show the average value of the latest 3 times capacity is full.
  • Page 13: Static Mode

    Auxiliary measuring function Static mode Cuff detection This function is mainly for professional personnel to enter the static mode to test the monitor through standard pressure gauge. If the cuff winded properly, it will show the '' '' icon. Otherwise it will Warning: normal users don't need to know this function and also do not show the '' '' icon, then press the ''...
  • Page 14 Common questions of blood Pressure measurement Static mode 2. Entering the static mode Press the '' '' button and hold, meanwhile p oke the side reset key with the tool. Hold for about 3 seconds then release the '' button. Then screen will show the pressure value '' '' , the date and time, mmHg.
  • Page 15: Common Questions Of Blood Pressure Measurement

    Common questions of blood Pressure measurement Common questions of blood Pressure measurement 1. What is blood pressure? 3. Why measure Blood Pressure at home? Blood pressure measured at a clinic or doctor's office may cause apprehension Blood pressure is the force exerted by blood against the walls of the arteries. can produc e an elevated reading, 25~30 mmHg higher than that measured Systolic pressure occurs when the heart contracts.
  • Page 16 Common questions of blood Pressure measurement Common questions of blood Pressure measurement 6. When is the best time to measure blood pressure? Note: There is no definition about hypopiesia, and generally SYS (systolic pressure) less than 90mmHg or DIA (diastolic pressure) less than After urination, before breakfast in the morning.
  • Page 17: Common Fault And Trouble Shooting

    Common fault and trouble shooting Common fault and trouble shooting The table below shows the possible fault displaying icon, possible reason, and solutions. Common fault Solutions Wrong Fault cause Solution indication It doesn't work after pressing the The pressure value did not reach Please check the cuff for tightness...
  • Page 18: Features And Technical Parameters

    Features and technical parameters Features and technical parameters 1. Features Suitable wrist circumference: 13.5-19.5cm Small delicate design Dimensions:Approx.L89 mm x W62 mm x H21 mm 74 groups of memory Wight: about 109g Average value display of three times measurement 4. Operation and storage conditions: kPa &...
  • Page 19: Electromagnetic Compatibility Information

    1) during and after exposure to non-transient phenomena; and Guidance and manufacture s declaration- electromagnetic emission 2) after exposure to transient phenomena. The W10/W10S/W10T/W10F Electronic Blood Pressure Monitor is intended for use in the e) The maximum error of repeated BLOOD PRESSURE DETERMINATION is electromagnetic environment specified below.
  • Page 20 Table 3 For ME EQUIPMENT and ME SYSTEMS that are not LIFE-SUPPORTING Guidance and manufacture s declaration-electromagnetic emission Guidance and manufacture s declaration-electromagnetic immunity W10/W10S/W10T/W10F Electronic Blood Pressure Monitor is intended for use in the W10/W10S/W10T/W10F Electronic Blood Pressure Monitor is intended for use in the electromagnetic environment specified below.
  • Page 21 Electromagnetic compatibility information Electromagnetic compatibility information Table 4 Test specifications for ENCLOSURE PORT IMMUNITY to RF wireless communications equipment Maximum IMMUNITY Test NOTE If necesary to achieve the IMMUNITY TEST LEVEL, the distance between the transmitting antenna and the Band Distance frequency power...