Yuwell YE680B User Manual

Yuwell YE680B User Manual

Electronic blood pressure monitor

Advertisement

Shanghai International Holding Corp.GmbH(Europe)
Eiffestrasse 80,20537 Hamburg Germany
JIANGSU YUYUE MEDICAL EQUIPMENT & SUPPLY CO.,LTD.
Sales Center Address: Huanyuan East Road No.1,Xuzhuang
Software Park, Nanjing, Jiangsu Province, P.R. China, 210000
Manufacturing Address: YunYang Industrial Park
DanYang, Jiangsu Province, P.R. China, 212300
http://www.yuwell.com
1530173-0A
YE680B
Electronic Blood Pressure Monitor
User's Manual
Please read the user's manual closely before using!

Advertisement

Table of Contents
loading

Summary of Contents for Yuwell YE680B

  • Page 1 YE680B Electronic Blood Pressure Monitor Shanghai International Holding Corp.GmbH(Europe) Eiffestrasse 80,20537 Hamburg Germany JIANGSU YUYUE MEDICAL EQUIPMENT & SUPPLY CO.,LTD. User's Manual Sales Center Address: Huanyuan East Road No.1,Xuzhuang Software Park, Nanjing, Jiangsu Province, P.R. China, 210000 Manufacturing Address: YunYang Industrial Park DanYang, Jiangsu Province, P.R.
  • Page 2: Table Of Contents

    Product Features Contents Before using Product features............ Data storage Backlit display Operation guide............Parts................Important notes............Maintenance............Battery installation..........Time and date setting........... Voice/Unit setting..........Measuring method Using method of cuff..........Measuring posture..........Start measuring............Blood pressure range indicator......Memory function............ Auxiliary measuring function......
  • Page 3: Operation Guide

    Operation guide Operation guide Measurement This device uses the oscillometric method of 1. Using method of cuff blood pressure measurement。 Wearing the cuff and make the lower edge 2~3cm above the elbow, keep the air tube Please follow the steps as shown below inside of the arm.
  • Page 4: Parts

    Parts Operation guide 1. Main part Check the records Press the button of " " check the measuring Display records. mmHg mmHg This monitor can display the average P/min measurement store records. Member MEMBER button (Please turn to page 24 for details) Memory Start/Pulse button...
  • Page 5 Parts Parts Display 2. Cuff: The suitable upper-arm circumference: 22cm~45cm Time and date Rubber air Air plug tube Low voltage SYS(systolic) Cuff Blood pressure Member level display 3. Adapter DIA(diastolic) Memory Cuff Wrapping Pressure unit Detection Pulse rate Records number Deflation/Inflation Movement Error...
  • Page 6: Important Notes

    Important notes Important notes signs and symbols 1. Range of application Pay attention with the symbols shown here to This product is intended to measure the blood prevent harm or damage to the user. pressure and pulse rate of adult at household or Caution medical center(not suitable for neonate,...
  • Page 7 Important notes Important notes Do not measure continuously. (5 minutes or arm with an arterio-venous (A-V) shunt. more should be spared between Do not use the cuff on the arm where the side measurements). of a mastectomy. Please reinstall the batteries and start again if Note that It will lose function on the same limb cannot measure.
  • Page 8: Maintenance

    Important notes Maintenance Please observe the following items to protect Please disconnect the plug of adapter with the device and ensure the accuracy mains when you need to safely terminate measurement. operation of ME EQUIPMENT. Please store the monitor and accessories When it is dirty in single patient daily use, properly after use.
  • Page 9: Battery Installation

    Time and date setting Battery installation Open the battery cover and install four AA The monitor will store the measuring results batteries properly. Then close the cover with a automatically by the management system. click sound. It is necessary to reset time and date after Aligning the +ve and poles of each battery installing new batteries or connecting to DC with the +ve and -ve signs imprinted on the...
  • Page 10: Voice/Unit Setting

    Time and date setting Voice/Unit setting Pressing the " " button to enter the voice setting. The size of the sound ranges from 01 to 05 and OFF. Press " "choose the volume. After finishing the volume setting, pressing the " "...
  • Page 11: Using Method Of Cuff

    Using method of cuff Using method of cuff Using method of cuff Tips! Wind the cuff around the upper arm. ( as shown Either of arms can be measured. In the picture) Keep the lower edge of the cuff at the position Cuff connecting above 2-3cm to the Connect the air connector of the cuff to the...
  • Page 12: Measuring Posture

    Measuring posture Start measuring Don't eat, smoke, drink, take bath or do any Keep upper high impact sport within half an hour before bareness wearing thin clothes measuring. Measurements shall be taken at the same time every day. Keep the center of cuff and heart at the same level Sit still for 5 minutes before the...
  • Page 13 Start measuring Start measuring mmHg mmHg P/min MEMBER measurement state Full screen display state 2. Measurement finished After measurement, the monitor will show the SYS, DIA and pulse rate, then inflate the air automatically. Inflate state The zeroing state Cuff wear state The monitor starts measuring automatically after inflation finished, and the measuring icon "...
  • Page 14: Blood Pressure Range Indicator

    Start measuring Blood pressure range indicator 3. Take off the cuff If the SYS is higher than 139mmHg or DIA higher than 89mmHg means having high blood 4. Shut pressure. Please contact with doctor for advice. Press the" "button to shut down. Also it Also the Blood pressure range indicator can show the blood pressure intuitively.
  • Page 15: Memory Function

    Memory function Memory function Tips! 1. Press the " "button for the records. The monitor will store the measurement data A. Press the" "button to show the average automatically (including time, date, blood value of the latest 3 times measurement. pressure and pulse), and the upper limit of B.
  • Page 16: Auxiliary Measuring Function

    Memory function Auxiliary measuring function Cuff Wrapping Detection C. Read the recorded data by pressing the If the cuff winded properly, it will show the " "button as the sequence: "1", "2" " "icon. Otherwise it will show the" " .."99"(max).
  • Page 17: Static Mode

    Static mode Static mode This function is mainly for professional Entering the static mode personnel to enter the static mode to test the Press the " "button and hold, meanwhile monitor through standard pressure gauge. install the batteries. Hold on for about 3 Warning: Normal users don't need to know this function and also do not operate.
  • Page 18 kPa/mmHg k a/mmHg 12.0~18.5kPa 8.0~11.9kPa 90~139mmHg 60~89mmHg 12.0~13.2kPa 18.7~21.2kPa 140~159mmHf 90~99mmHg 21.3~23.9kPa 13.3~14.5kPa 160~179mmHg 100~109mmHg ≥24.0kPa ≥14.7kPa ≥110mmHg ≥180mmHg...
  • Page 19 Note: There is no definition about hypopiesia, and generally SYS(systolic pressure) less than 90mmHg or DIA (diastolic pressure) less than 60mmHg is called hypotension. 5. Blood pressure variations? An individual's blood pressure varies greatly on a daily and seasonal basis. It may vary by 30 to 50 mmHg due to various conditions during the day.
  • Page 20 (300mmHg) The " "icon twinkle...
  • Page 21: Technical Parameters

    Technical parameters Technical parameters Operating/Storage 70kPa to 106kPa Model YE680B atmospheric Display LCD digital display pressure Measuring Oscillation mensuration There is the potentia risk of radio frequency method interference between the device and other Measuring range 0-300mmHg devices. If there is, please find out the...
  • Page 22: Electromagnetic Compatibility Information

    The customer or the user of the specified below. The customer or the user of the YE680B YE680B should assure that it is used in such and environment should assure that it is used in such and environment. Immunity...
  • Page 23 (MHz) (V/m) (MHz) (MHz) The YE680B is intended for use in the electromagnetic environment Pulse specified below. The customer or the user of YE680B should assure TETRA 400 380-390 modulation that it is used in such an environment. 18 Hz...
  • Page 24: Health Diary