Yuwell YE660D User Manual
Yuwell YE660D User Manual

Yuwell YE660D User Manual

Electronic blood pressure monitor
Hide thumbs Also See for YE660D:

Advertisement

Quick Links

142.5mm
技术要求:
材质:80g双胶纸
尺寸:180x142.5mm
骑马订
第6页中标识"
"图标中蓝色部分保持蓝色印刷:C90%, M60%, Y10%, K0
标记 处数
更改文件号
签 字
180mm
YE660D
英文说明书(CE)
日期
80g双胶纸
A/0
注:此中虚线仅作工艺示意,无实际生产意义。
YY-BPM0034C-01
图样标记
B
1
江苏鱼跃医疗设备股份有限公司
数量
重量
比例
1:1
1
让科技律动生命

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the YE660D and is the answer not in the manual?

Questions and answers

Summary of Contents for Yuwell YE660D

  • Page 1 180mm 142.5mm 注:此中虚线仅作工艺示意,无实际生产意义。 技术要求: 材质:80g双胶纸 尺寸:180x142.5mm 骑马订 第6页中标识“ ”图标中蓝色部分保持蓝色印刷:C90%, M60%, Y10%, K0 YY-BPM0034C-01 YE660D 英文说明书(CE) 图样标记 数量 重量 比例 日期 标记 处数 更改文件号 签 字 设 计 视 角 共 张 第 张 制 图 工 艺 80g双胶纸 审 核...
  • Page 2 YE660D Electronic Blood Pressure Monitor Metrax GmbH Rheinwaldstr. 22, D-78628 Rottweil, Germany User's Manual JIANGSU YUYUE MEDICAL EQUIPMENT & SUPPLY CO.,LTD. NO.1 Baisheng Road Development Zone, Danyang, Jiangsu 212300 CHINA www.yuwell.com YY-BPM0034C-01(A/0) Date of issue :2024.05 Please read the user's manual closely before using!
  • Page 3: Table Of Contents

    Product Features Contents Before using Voice function Indication for Product features............This feature only applies irregular to the model with voice Operation guide............heartbeats function. Product structure and parts........Cautions..............Important notes............Battery installation..........Voice volume and u nit setting.....
  • Page 4: Operation Guide

    Operation guide Operation guide Measurement This device uses the oscillometric method of blood pressure measurement. 1. Using method of cuff Please follow the steps as shown below. Wearing the cuff and make the lower edge 2 ~3cm above the elbow, keep the air tube inside of the arm. Power-on (Please turn to page 13 for details.) Connect the power source as shown below.
  • Page 5: Product Structure And Parts

    MFR: WEIHAI HITAI ELECTRONICS Co.,LTD. Battery cover EU Model: HT-C38B-0510EW US Model: HT-C38B-0510WW 2. Cuff UK Model: HT-C38B-0510UW There are 6 types of cuff provided by yuwell. 4. Display Please subject to the received type. Battery power icon Rubber air tube SYS(systolic)
  • Page 6: Cautions

    Important notes Cautions Pay attention with the symbols shown here to Statement:The device is a medical device. prevent harm or damage to the user. 1. Intended purpose This product is intended to measure the blood Caution pressure and pulse rate of adult who is more than 12 years old at household or medical Type BF applied part center (not suitable for neonate, pregnancy or...
  • Page 7 Important notes Important notes Operator can't touch the accessible part of adapter/ Do not take the measurement in a moving vehicle. main unit and patient at the same time. Do not measure continuously. (At least 2~3 Warning: Do not use the cuff on the arm where minutes or more should be spared between two the side of a mastectomy or lymph node clearance.
  • Page 8: Battery Installation

    Tips! mode. Please use only the authorized Yuwell AC adapter Statement: If the monitor has not been used and (output DC 5V 1A). If you need to use a AC adapter, stored in the required temperature, altitude and...
  • Page 9: Voice Volume And Unit Setting

    Voice volume and unit setting Using method of cuff Tips! Either of the upper-arms can be measured. Voice volume setting Do not measure other parts of the body. Press the" " button and the" " button at the same time for more than 3 seconds till the Cuff connecting number starts flashing.
  • Page 10: Using Method Of Cuff

    Using method of cuff Measuring posture Stick the cuff tightly. Keep the upper arm Note: The cuff should be wearing comfortably, bareness or wearing thin clothes avoiding too tight or loose. Keep the center of cuff and heart at the same level Sit straight and flat the arm on table with palm up, and keep the center of cuff and heart at the same level.
  • Page 11: Start Measuring

    Start measuring Start measuring Please relax as much as possible and not talk or Don't eat, smoke, drink, take bath or do any move during the measurement procedure. high-intensity sport within an hour before measuring. Measurements shall be taken at the same time every day.
  • Page 12: Blood Pressure Range Indicator

    Start measuring Blood pressure range indicator 3. Take off the cuff If the SYS is higher than 139mmHg or DIA higher than 89mmHg means having high blood 4. Shut down pressure, please contact with doctor for advice. Press the " "...
  • Page 13: Memory Function

    Memory function Memory function C. Read the recorded data by pressing the " " Tips! button as the sequence: "1", "2" .."90" (max). The monitor will store the measurement data Then return to the 1st. Holding the " " button automatically (including blood pressure and to search the data quickly.
  • Page 14: Static Mode

    Static mode Static mode Note: When the measured This function is mainly for professional personnel to enter the static mode to test the monitor pressure exceeds 300mmHg during static test, pressure value and " " through standard pressure gauge. are displayed, indicating the Warning: Normal users don't need to know measurement result exceeds the this function and also do not operate.
  • Page 15: Common Questions Of Blood Pressure Measurement

    Common question of blood pressure Common question of blood pressure measurement measurement 1. What is blood pressure? 4. WHO Blood Pressure Classification? Blood pressure is the force exerted by blood Standards to assess high blood pressure, without against the walls of the arteries. Systolic pressure regard to age, have been established by the world occurs when the heart contracts.
  • Page 16: Common Fault And Trouble Shooting

    Common question of blood pressure Common fault and trouble shooting measurement Common fault Solutions 5. Blood pressure variations? It doesn't work after pressing Check the batteries are installed correctly An individual's blood pressure varies greatly on a the '' '' button with batteries Replace new batteries installation daily and seasonal basis.
  • Page 17: Alarm System

    Alarm system Maintenance Please observe the following items to protect the When the determined blood pressure is outside device and ensure the accuracy of measurement. the rated range, there is a visual alarm signal on Please store the monitor and accessories properly the display screen.
  • Page 18: Features And Technical Parameters

    Features and technical arameters Features and technical arameters 1. Features 3. Operation and storage conditions: 90 groups of memory Operation conditions: Average value display of three times measurement a temperature range of +5℃ to +40℃; a relative humidity range of 15% to 90%, 2.
  • Page 19: Electromagnetic Compatibility Information

    Guidance and manufacture s declaration- electromagnetic emission This equipment might not offer adequate protection The YE660D Electronic Blood Pressure Monitor is intended for use in to radio-frequency communication services. The electromagnetic environment specified below. The customer or user...
  • Page 20 LIFE-SUPPORTING Guidance and manufacture s declaration-electromagnetic emission Guidance and manufacture s declaration-electromagnetic immunity The YE660D Electronic Blood Pressure Monitor is intended for use in the electromagnetic environment specified below. The customer The YE660D Electronic Blood Pressure Monitor...
  • Page 21 Electromagnetic compatibility information Table 4 Test specifications for ENCLOSURE PORT IMMUNITY to RF wireless communications equipment IMMUNITY Test TEST Band Service frequency Modulation LEVEL (MHz) (MHz) (V/m) Pulse 380 to 390 TETRA 400 modulation 18 Hz ±5 kHz deviation GMRS 460, FRS 460 1 kHz sine Pulse LTE Band 13, 17...

This manual is also suitable for:

Ye-61mcYe-61lcYe-62mcYe-62lcYe-63mcYe-63lc

Table of Contents