LEGAL STATEMENT Teledyne, the Teledyne Logo, Gas Measurement Instruments, GMI, and Protégé ZM are registered and/or unregistered marks of Teledyne Gas Measurement Instruments Ltd, also referred to as “the Company.” All rights reserved. No part of this documentation may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without written permission from the Company.
Protégé ZM SYSTEM GUIDE DISPOSAL ADVICE Dispose of the monitor carefully and with respect for the environment. If returned, the Company will dispose of the monitor without charge. AREAS OF USE Exposure to certain chemicals can result in a loss of sensor sensitivity. Where such environments are known or suspected it is recommended that more frequent response checks are carried out.
Protégé ZM SYSTEM GUIDE Table of Contents General Information ........................6 1.1. Guide Conventions ........................6 1.2. Certification and Approvals ....................7 1.3. General Safety Information ....................8 1.4. Warnings and Cautions - Monitor and Test Station ............9 1.5. Warnings and Cautions - Sensor Use and Care ..............
Page 5
Protégé ZM SYSTEM GUIDE 5.3. Calibrating the Monitor Using the IR Connect Software ..........36 5.4. Calibrating the O Monitor Using the Front Button ............38 Maintenance ........................... 39 6.1. Self-Testing the Monitor ...................... 30 6.2. Retrieving the Event Log using IR Connect .................
Protégé ZM SYSTEM GUIDE 1. General Information WARNING: READ, UNDERSTAND AND FOLLOW THE ENTIRE CONTENT OF THIS GUIDE PRIOR TO USE. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH. This guide describes the steps required to use the Protégé ZM Portable Gas Monitor and optional system products.
Protégé ZM SYSTEM GUIDE 1.2. Certifications and Approvals The Test Station has the following approvals: Symbol Notes European Mark of Conformity Federal Communications Commission UKCA (UK Conformity Assessed) The IR Connect has the following approvals: Symbol Notes European Mark of Conformity 1.3.
Page 8
This service can be accessed by contacting Customer Services, who will be happy to assist. Please do not send products back to Teledyne GMI. In other parts of Europe, other systems are in place. Please contact your local provider of Teledyne GMI products for more details.
Protégé ZM SYSTEM GUIDE WARNING: ONLY USE THE MONITOR TO MONITOR ATMOSPHERE FOR THE GASES AND CONCENTRATIONS FOR WHICH IT IS SET-UP TO DETECT. WARNING: TO PREVENT IGNITION OF AN EXPLOSIVE ATMOSPHERE, READ AND ADHERE TO THE MANUFACTURER’S LIVE MAINTENANCE PROCEDURES.
Protégé ZM SYSTEM GUIDE 1.6. Warnings and Cautions – Battery Use and Care Caution: No attempt should be made to alter or repair the monitor. Caution: Do not attempt to replace the monitor’s battery. It is not replaceable. Caution: Discard monitor as soon as the battery indicator shows fully discharged battery.
Protégé ZM SYSTEM GUIDE 2. Introduction 2.1. Monitor Overview and Optional System Products The Protégé ZM is a portable clip-on single gas disposable monitor that is operated with a single button and has a 2 year life span. Comes with a non-field replaceable lithium-ion battery, filter and sensor already installed and ready for use.
Page 12
Protégé ZM SYSTEM GUIDE The monitor ships preconfigured and ready for operation using the factory default settings. However, user may to reconfigure some of the parameters based upon the application. See Configuring the IR Connect Software Parameters section for more details. IR Interface Port LED Alarm Alligator Clip...
Page 13
Protégé ZM SYSTEM GUIDE USB Cable Comms Window Figure 2-3: Major parts of the IR Connect 087-0048 Revision 1...
Above software is only compatible with the Microsoft Windows operating system and supports the following versions: XP, Vista, 7, 8, 10, and 1 1. Installers of the IR Connect and Test Station Software can be downloaded directly from the Teledyne Gas & Flame Detection website.
Protégé ZM SYSTEM GUIDE Figure 3-2: IR Connect - successful Read Device 3.2.2. Adjusting the Monitor Configuration The various parameters available are displayed in Figure 3-2 (appears after establishing communication between the IR Connect and the Monitor). These parameters, also detailed in the table below, allows users to program the individual Monitor to meet the specific requirements of the application.
Page 16
Protégé ZM SYSTEM GUIDE Item Details Self-Test Interval Allows adjustments to this item. Default = 20hours Range = 6 to 24hours Display This setting adjusts the detector display to show either ‘Sensor/Life Remaining’ , ‘Sensor Reading’ , or ‘Life Remaining’. In ‘Sensor/Life Remaining’...
Protégé ZM SYSTEM GUIDE Figure 3-3: IR Connect - successful Write Device WARNING: AFTER MAKING CHANGES TO HIGH/LOW ALARM PARAMETERS AND PERFORMING A WRITE DEVICE COMMAND, PERFORM A READ DEVICE COMMAND TO VERIFY CHANGES. THIS ENSURES DESIRED CHANGES HAVE BEEN STORED IN THE MONITOR MEMORY.
3.2.4. Upgrading the Monitor Firmware Upgrades may include product improvements to add additional features or to enhance monitor performance. Most firmware upgrades are not required unless specifically notified by Teledyne GMI. 1. Connect the Monitor to the PC using the IR Connect dongle.
Protégé ZM SYSTEM GUIDE 3.3. Test Station Software The Test Station Software enables users to execute the following tasks: • Modify the software settings. • Modify the setup of the Test Station. • Change the monitor settings. • Retrieve data from the monitor’s datalogger. •...
Protégé ZM SYSTEM GUIDE Figure 3-11: Test Station - Successful Connection 3.3.2. Adjusting Configuration of the Software To adjust the configuration of the software, access the ‘Config’ tab within the software. Below tabled details the available configuration items: Item Details Date Format Customize how the date is displayed in the software, including on printed certificates and in datalogger.
Protégé ZM SYSTEM GUIDE Item Details Print Adjust various attributes of the test certificate format, including: • Text displayed in the document footer (Bottom Left / Right). • Template of the certificate’s main section (Format). • Text style for the document (Font). •...
Page 22
Protégé ZM SYSTEM GUIDE Item Details Max Bump Time Set the maximum allowable time for a bump test. If the monitor being tested fails to reach the Bump Pass Limit before this specified time, the bump test will FAIL. Bump Pass Limit Define the pass limit value for the bump test.
Protégé ZM SYSTEM GUIDE Note: Click the ‘WRITE’ button after altering the parameters to ensure the new settings are saved to the device. 3.3.4. Adjusting Configuration of the Monitor The Test Station has the ability to change the Monitor’s settings using two approaches: •...
Page 24
Protégé ZM SYSTEM GUIDE • LOW Alarm threshold • HIGH Alarm threshold • STEL Alarm threshold • TWA Alarm threshold • Display mode • Option to enable/disable visual alarm for Bump Due • Option to enable/disable the ability to perform manual Self-Test For more information on these attributes, refer to Section 3.2.2: Adjusting the Monitor Configuration.
Page 25
Protégé ZM SYSTEM GUIDE 6. Optional: The Test Station is equipped with the capability to store a firmware upgrade file for the monitor and can automatically update any older monitor firmware during a bump test or calibration. To utilize this feature, the ‘Allow Firmware Updates’ option must be enabled in the ‘Docking Station’...
Protégé ZM SYSTEM GUIDE 4. Optional: To update the monitor firmware, click the ‘Firmware download’ button. This will load the firmware update file stored in the station. Upon completion of the download, the result will be displayed in the status table. Figure 3-23: Firmware download status •...
Page 27
Protégé ZM SYSTEM GUIDE • Start Purge - This function clears all logs from the Test Station.. • Load - This option is used to load a single log of bump test and calibration from local storage onto the Test Station. Figure 3-26: Log tab operations Once downloaded, the log files are organized into five categories, each accessible through the corresponding tab in the software:...
Page 28
Protégé ZM SYSTEM GUIDE Description Calibration This section contains the calibration history of the monitors. When a user selects any log from the list, its details will appear on the right side of the screen, and a print preview will be available in the ‘Print’ tab. Bump Test This tab shows the bump test history of the monitors.
Protégé ZM SYSTEM GUIDE 3.3.6. Printing Calibration and Bump Test Certificates The ‘Print’ tab enables the user to create and print a calibration or bump test certificate based on the data selected in the ‘Log’ tab. Figure 3-28: Test Station Software - Print tab The following functions are available in this tab: •...
Page 30
Protégé ZM SYSTEM GUIDE • Generates a report file and sends it via email at the scheduled time. To initiate the Auto-Mode, click on the ‘Auto’ button located in the bottom section of the window. Once activated, the software will display the date and time of the next scheduled download. Figure 3-30: Auto-Mode 087-0048 Revision 1...
Protégé ZM SYSTEM GUIDE 4. Test Station Operation 4.1. Test Station LEDs and Buttons Figure 4-1: Test Station LEDs and Buttons Item State Indicator Power LED Solid Green Battery Charged Blinking Green Battery Low Solid Orange Firmware update in progress Blinking Red USB memory not installed Unit 1 to 4 LEDs...
Protégé ZM SYSTEM GUIDE Caution: The station can only be charged using the DC power adapter included in the package. Note: The station does not charge while bump tests or calibrations are in progress. Note: If the battery is low (indicated by the power button blinking green), charge the station for 30 minutes before performing a bump test or calibration.
Protégé ZM SYSTEM GUIDE Ensure that the types and concentrations of the gases match the test station’s configuration. The Test Station Software enables you to set specific gas concentrations. The default configuration for gas concentrations is as follows: • H S (Hydrogen Sulfide): 25 ppm •...
Protégé ZM SYSTEM GUIDE • Clean the Test Station. Remove devices and disconnect from the power source. Use only a soft cloth to wipe surfaces. If necessary, a mild detergent may be used. Ensure it is dried thoroughly before applying power or replacing devices. WARNING: DO NOT USE THE EQUIPMENT WHEN AN EXPLOSIVE ATMOSPHERE MAY BE PRESENT.
Protégé ZM SYSTEM GUIDE 5. Calibration & Bump Test WARNING: OPERATING A DEVICE THAT HAS EXCEEDED ITS CALIBRATION DATE CAN CAUSE FALSE READINGS OF DETECTED GASES. READINGS OBTAINED WHILE MONITOR IS OUT OF CALIBRATION ARE INVALID AND COULD LEAD TO DEATH OR INJURY. The Company recognizes the potential of the monitor as a life saving device when operated and maintained correctly.
Protégé ZM SYSTEM GUIDE 5.2. Bump Testing using Calibration Adapter Equipment required: • Calibration gas – Verify the concentration level exceeds the set points of the monitor, and ensure the expiration date of the cylinder has not passed. • Tygon tubing – 2 feet of 3/16” ID •...
Page 37
Protégé ZM SYSTEM GUIDE 1. Launch the IR Connect software. 2. Connect the monitor to the PC as described in Section 3.5 of this manual. 3. Press the ‘SENSOR CALIBRATION’ , and a dialog box will appear as shown in Figure 5-2.
Protégé ZM SYSTEM GUIDE Note: Since the IR Connect is no longer connected to the monitor, once the count- down in Status Bar is finished, the Dialog Box will display a ‘Calibration... Time-out’ message. 9. Press ‘CLOSE’. 5.4. Calibrating the O Monitor Using the Front Button By default, the Protégé...
Protégé ZM SYSTEM GUIDE 6. Maintenance 6.1. Self-Testing the Monitor Before daily use, the monitor prompts the user to perform a self-test. This procedure is a straightforward and reliable method to ensure the safe operation of the monitor. The test involves activating the audio, visual, and vibration alarms, as well as testing the sensor.
Page 40
Protégé ZM SYSTEM GUIDE Steps A successful self-test results in the monitor reverting to the standard operating screen, displaying a CHECK MARK where the TEST icon was previously, accompanied by a short audible beep. By default, the monitor prompts another self-test 20 hours after the button was pressed.
Protégé ZM SYSTEM GUIDE 6.2. Retrieving the Event Log using IR Connect By default, the monitor stores the last twenty-five (25) alarm events. It uses a First In First Out (FIFO) method for storage. This means that the twenty-sixth event replaces the first event, and so on. This information can be downloaded to a PC using the IR Connect Software.
Protégé ZM SYSTEM GUIDE 6.3. Hibernating the Monitor using the IR Connect Software This operation preserves the battery when the monitor is not in service. Note: The hibernation function is only available in the CO and H S monitors. Note: It is recommended to save the event log prior to placing the monitor in hibernation. Once hibernation occurs, all prior event logs are erased.
6.5. Upgrading the Monitor Firmware using IR Connect Upgrades may include product improvements to add additional features or to enhance monitor performance. Most firmware upgrades are not required unless specifically notified by Teledyne GMI. 1. Launch the IR Connect software.
Press the button to acknowledge the error. Then corrupt attempt to load a new firmware image into the device via the IR Connect. If unsuccessful, contact Teledyne GMI. Bad battery Contact Teledyne GMI Bad sensor Contact Teledyne GMI. 087-0048 Revision 1...
Protégé ZM SYSTEM GUIDE 6.7. Troubleshooting Caution: Repairs on the equipment should only be attempted by trained and qualified personnel. Note: Do not move the monitor during the firmware upgrade. Item Symptom / Cause Solution IR Connect Monitor Connect Error •...
Page 46
• Attempt to use the Monitor again. If the Monitor fails three times, please get in touch with Teledyne GMI for further assistance. Red status Bar appears • Check that the Test Station is powered up. after READ or WRITE •...
Protégé ZM SYSTEM GUIDE 7. Accessories Part Number Part Number Category Description EMEA & APAC Americas Monitor 2025956 074-0564 Calibration Cap / Adapter 661 18 096-3167 Tygon Tubing 3/16” ID , 10’ length 2025957 073-0355 Alligator belt clip Calibration Station 2027001 Bump Test &...
Page 48
Protégé ZM SYSTEM GUIDE 087-0048 Revision 1...
Protégé ZM SYSTEM GUIDE Appendix A: Specifications Monitor Specifications Battery Life 2 years, 4 minutes of alarm time per day Alarms Visual, vibrating, audible 95dB Test Full function self-test on activation and every 20hours; Continuous automatic battery tests Datalogg Last 25 events Housing Impact Adsorbent Overmould Hydrogen Sulphide...
Page 50
Protégé ZM SYSTEM GUIDE IR Connect Specifications Range 2 to 16” (50 to 400mm) Power USB (5V) Dimensions 1.5”x1.7”x1.1” (39 x 45 x 29mm) Weight 0.7oz (20g) Operating Temperature 50 to 104°F (10 to 40°C) Operating Humidity 5% to 95% RH, Non-Condensing Bump Test &...
SYSTEM GUIDE Appendix B: Gas Interferences It is known that a limited number of chemical compounds can interfere with gas detection. Teledyne GMI endeavours to identify potential gas interferences that may affect gas sensors. However, it is important to note that not all existing chemical compounds have been tested for interference.
Protégé ZM SYSTEM GUIDE Appendix C: Technical Support This product is designed to provide you with reliable, trouble-free service. Contact your regional technical support if you have technical questions, need support, or if you need to return a product. Details can be found at: www.teledynegasandflamedetection.com Note: When returning a product, contact Technical Support to obtain a Return Material Authorization (RMA) number prior to shipping.
Page 53
AMERICAS EMEA ASIA PACIFIC 14880 Skinner Road Inchinnan Business Park 290 Guigiao Road Cypress, Renfrew, PA4, 9RG Pudang, Shanghai 201206 TX 77249, USA Scotland, UK People’s Republic of China Tel: +1-713-559-9200 Tel.: +44 (0) 141 812 321 1 Tel.: +86-21-3127-6373 www.teledynegasandflamedetection.com 087-0048 Revision 1...