Download Print this page
Microlife CVS BP3KX1-1B Instruction Manual
Microlife CVS BP3KX1-1B Instruction Manual

Microlife CVS BP3KX1-1B Instruction Manual

Bluetooth blood pressure monitor

Advertisement

Quick Links

CVS
INSTRUCTION MANUAL
Bluetooth"'
Blood
Pressure
Monitor
Model
BP3KX1-1B
#
QUESTIONS? 1-800-568-4147

Advertisement

loading
Need help?

Need help?

Do you have a question about the CVS BP3KX1-1B and is the answer not in the manual?

Questions and answers

Summary of Contents for Microlife CVS BP3KX1-1B

  • Page 1 INSTRUCTION MANUAL Bluetooth"' Blood Pressure Monitor Model BP3KX1-1B QUESTIONS? 1-800-568-4147...
  • Page 2 ® detected. The device can be connected via Bluetooth to a smart mobile device running the Microlife Connected Health App. This blood pressure monitor IS intended to be used: • For self-measurement/monitoring of blood pressure and pulse in adults, including those with Diabetes mellitus;...
  • Page 3 ×Service the device when being used or when power is supplied. When the device is not in use and power is removed, cuff assembly, batteries and ac adapter (if applicable) may be replaced by the user with Microlife supplied replacements. No other parts/components are accessible.
  • Page 4 • When replacing the batteries, ensure all the batteries are replaced simultaneously to avoid battery damage and potential damage to the monitor. Microlife USA does not recommend using rechargeable batteries. • To avoid inaccurate measurements and to lessen any...
  • Page 5 measurements, injury, and/or damage the device. STANDARDS In addition to the standards stated in the Instruction Manual: • This medical device is compliant with medical device and non-invasive blood pressure monitor standards IEC 60601-1, IEC 60601-1-2, IEC 60601-1-11, and AAMI/ANSI/IEC 80601-2-30, and •...
  • Page 6 Changes or modifications to the product are not approved by Microlife USA and could void the user's authority to operate the equipment under FCC jurisdiction. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
  • Page 7 3.5. Setting the date and time 3.6. Setting alarm time 3.7. Select the user 3.8. Select the measuring mode: standard or Microlife Averaging Mode 3.9. Microlife Averaging Mode (MAM) 3.10. Connecting the cuff and monitor 3.11. Using the AC power adapter 4.
  • Page 8 7. How is blood pressure measured? 7.1. What is blood pressure, and why does it fluctuate? 7.2. Measurement guidelines 7.3. What can I do to change my blood pressure? 8. Care and maintenance 9. Limited warranty 10. Technical specifications 11. How to contact us...
  • Page 9 1.2. Diabetes mellitus validation Diabetes, and stiff arteries, can make accurate blood pressure readings a challenge. Microlife's commitment to health has led to a breakthrough clinical validation for accurate readings in the presence of diabetes. This innovation reinforces our commitment to quality, accuracy, and helping you take control of your health.
  • Page 10 Components of your blood pressure monitor 2.1. Blood pressure monitor Stand Display Cuff socket Battery compartment AC Adapter Port Screen Lock MAM mode switch Select 1 or 3 Measurements...
  • Page 11 User Button Systolic Traffic light Diastolic indicator Pulse SET Button Memory Button START/STOP Button Error1 Cuff signal indicator User 1 & 2 Error 2 Arm movement indicator Guest Error 3 Cuff pressure check Bluetooth® Memory Averaging Battery Indicator Date/Time Memory Pause Average Indicator «MyCheck»...
  • Page 12 2.2 Wide Range Cuff: For arm circumference 8.7” - 16.5” (22 cm - 42 cm) If you ever need to buy a replacement cuff, call us toll-free at 1-800-568-4147. Anti-Slip Cuff: Your wide range cuff is equipped with anti-slip grips that ease the process of correctly positioning the cuff on your arm.
  • Page 13 3. How do I get started? 3.1 Protective screen film There is a protective piece of static film covering the monitor’s screen. Please remove it before use. 3.2 Inserting the batteries After you have unpacked your device, insert the batteries. The battery compartment is located on the back of the device.
  • Page 14 To activate your monitor, push the switch on the right hand side of the monitor to the unlocked position. Please keep your monitor locked if you have no need to use the device to avoid lots of battery power consumption. 3.4.
  • Page 15 Before taking a measurement, be certain that the correct user has been selected. With the monitor unlocked, tap user icon to change users. 3.8. Select measuring mode: standard or Microlife Averaging Mode (MAM) This instrument enables you to select either standard (single measurement) or measurement averaging mode (automatic triple measurement).
  • Page 16 •After pressing the START/STOP button the selected Microlife Averaging Mode appears in the display as the MAM symbol. •The bottom, right-hand section of the display shows a 1, 2 or 3 to indicate which of the 3 measurements is currently being taken.
  • Page 17 must be reset by removing the plug from the instrument. If you have any questions regarding the AC adapter, call us at 1-800-568-4147. 4. How do I take a measurement? Please note: You should always be seated before and during measurement.
  • Page 18 call 1-800-568-4147. • A loose cuff or a sideways protruding air pocket causes false measurement values. With repeated measurements, blood accumulates in the arm, which can lead to false results. Consecutive blood pressure measurements should be repeated after a 1 minute pause or after your arm has been held up in order to allow the accumulated blood to flow away.
  • Page 19 The measurement results are displayed until you switch the device off. If no button is pressed for 1 minute, the device switches off automatically. h) When the unit is set to the MAM (Microlife Averaging Mode)
  • Page 20 setting, 3 separate measurements will take place in succession, after which your result is calculated and displayed as a single, averaged measurement (individual results are not displayed). There is a 15 second resting time between each measurement. A count-down indicates the remaining time between measurements.
  • Page 21 If it is necessary to interrupt a blood pressure measurement for any reason (e.g., the patient feels unwell), the “START/STOP” button can be tapped at any time. The device then immediately lowers the cuff pressure automatically and enters sleep mode. 4.7.Hypertension risk indicator The bars on the left-hand edge of the display show the possible range for a blood pressure reading.
  • Page 22 4.8. Average Indicator «MyCheck» This symbol indicates after each measurement, if the most recent measured value lies below, above or on the same level as your stored average value (see also section 4.5.Memory: reviewing readings). •If the measured Systole or Diastole is more than 5mmHg higher than the stored average, the arrow shows upwards.
  • Page 23 We do not recommend using rechargeable batteries. 5. Bluetooth® functions and application (App) Please download the Microlife Connected Health App (referred to as App in this document) from Apple’s App Store® or Google Play® before pairing your devices.: 5.1 Bluetooth®...
  • Page 24 2 minutes if a smartphone does not connect to the device. 5.2 Bluetooth® pairing & app setup Open «Microlife Connected Health+» App on the smartphone (Make sure the app is running in the foreground, not in the back- ground.) Turn on Bluetooth®...
  • Page 25 Contact your doctor if you continue to get unusual readings. ERR bt Bluetooth® is malfunctioning. Contact your local Microlife distributor. Bluetooth®Symbol Bluetooth® connection error. Turn off blinks rapidly device Bluetooth® and close the app on the smartphone. Wait for 1...
  • Page 26 *If this or any other problem occurs repeatedly, please consult your doctor. Other possible errors and their solutions If problems occur when using the device, the following points should be checked and, if necessary, the corresponding measures are to be taken: Malfunction Remedy The display remains blank...
  • Page 27 result in a higher reading than at home under resting conditions. After the instrument has 1.Check cuff connections. inflated the cuff the 2.Ensure the unit has not pressure falls very slowly, been tampered with. or not at all. (No reasonable measurement possible.) 7.How is blood pressure measured? 7.1.What is blood pressure, and why does it fluctuate?
  • Page 28 detect possible changes in your values early and react appropriately. If you are undergoing medical treatment to control your blood pressure, keep a record of values along with time of day and date. Show these values to your physician. Never use the results of your measurements to independently alter the medication prescribed by your physician.
  • Page 29 differentiate between the common primary (essential) hypertension and secondary d)There are measures which you can take to reduce and even prevent high blood pressure. These measures must be permanent lifestyle changes. 1)Eating habits •Strive for a normal weight corresponding to your age. See your doctor for your ideal weight.
  • Page 30 9.Limited warranty Your Automatic Blood Pressure Monitor is warrantied for 5 years by Microlife USA Inc, against manufacturer defects for the original purchaser only, from date of purchase. The 5 year warranty applies to the monitor only. The following accessories are warrantied for 1 year: cuff and AC adapter.
  • Page 31 Accessories: ..... . .Cuff type: Wide range cuff for arm circumference 22-42 cm (8.7”-16.5”) Storage case Technical alterations reserved. Made in China 11.How to contact us Microlife USA, Inc. 1617 Gulf to Bay Blvd. Clearwater, FL 33755 Toll Free Help Line: 1-800-568-4147 Email: custserv@microlifeusa.com www.microlifeusa.com...