User and maintenance instructions FlowMaster II rotary driven electric pump, V Model and MSO*, series “B” Date of issue October Form number Version Indicates change.
Page 2
Contents Declaration of Conformity* .. U.K. Declaration of Conformity* .. Safety* .........
Page 3
Lincoln Industrial Corporation N. Hanley Road St. Louis, MO U.S.A. TEL: + () - FAX: + () - Authorized to compile the technical file: SKF Lubrication Systems Germany GmbH Heinrich-Hertz-Straße - Walldorf, Germany EMAIL: robert.collins@skf.com WEBSITE: www.skf.com...
Page 4
Lincoln Industrial Corporation N. Hanley Road St. Louis, MO U.S.A. TEL: + () - FAX: + () - Authorized to compile the technical file: SKF (U.K.) Limited Canada Close Banbury, Oxfordshire, OX RT, GBR EMAIL: robert.collins@skf.com WEBSITE: www.skf.com This U.K.
Page 5
Explanation of signal words Safety* CAUTION for safety Do not operate equipment without The assembly must be installed, maintained wearing personal protective gear. and repaired exclusively by persons familiar Wear eye protection. Protective with the instructions. equipment such as dust mask, non-skid NOTE Always disconnect power source Emphasizes useful hints and...
Page 6
Description Operation with System operation mechanical shut-off* with controller Model is a pumping unit designed to operate a Centro-Matic lubrication system. Units include a vent valve to relieve line When controller times out, lube cycle begins When attached, a mechanical shut-off pressure and recharge injectors.
Page 7
Fig. * Dimensions Ø 16 - / in (425 mm) Ø 15 - / in (394 mm) 37.9 in (963 mm) Ø / in 20.3 in (15 mm) (517 mm) 45° ) Mounting holes X ° apart. Indicates change. ...
Page 8
Install pump Pump operation Verify electric connections are accessible Fill reservoir to pump location. Mark center locations of all holes at Remove lower and upper pipe plugs from bottom of reservoir. side of reservoir to bulk fill. ...
Page 9
Diagram Wiring diagram Item Description V Battery + Fuse Amp Red wire, motor positive Motor Black wire, motor negative Vent valve Battery - ) System control contacts, manual switch, or other form of system control. NOTE Connect red motor lead to positive side of circuit.
Page 10
Outlet check service Maintenance Pump will not build up sufficient Keep area around pump clean. Clean off lubricant pressure if outlet check () is filling port area prior to filling reservoir. fouled. Foreign material may lodge beneath Clean area around filler after filling as check ball () or between check disc () lubricants will attract dirt.
Page 11
Follower Lift entire pump, vent valve, cover Remove follower weight () and assembly and follower out of reservoir. foam (). Replace foam with a new one. If follower foam appears to be damaged or Remove cable assembly () from ...
Page 12
Mechanical low level Fig. * Diagram Low level indicator indicator O-ring () may be damaged if indicator pin appears to drop prematurely or water is noticeable on top of follower, († Fig. IPB , page ). Remove eight bolts () and lock washers () that hold cover onto reservoir.
Page 13
Safety unloader valve Bare pump assembly Safety unloader valve () († Fig. IPB , Please refer to operation manual for page ) is not serviceable and should be bare pump assembly () († Fig. IPB , replaced if malfunction is apparent. Upon page ).
Page 14
Troubleshooting* Condition Possible cause Corrective action Pump does not operate. No electric power to pump: Turn on or connect electric supply to pump. Motor relay failure. Replace relay. Motor overheated. Turn power off for minutes and restart. Motor tripped out on locked rotor protection. Remove high pressure or repair cause of locked pump.
Page 15
Table Service parts Item Description Part number Quantity Vent fitting Hose assembly Hex head screw, - x Lock washer, Safety unloader ) Male run tee ...
Page 16
Table (continued) Service parts (continued) Item Description Part number Quantity Gasket, level sensor* ) Indicator nut O-ring ) Cable assembly Retaining ring ) Indicator bracket ...
Page 18
Fig. IPB * Fig. IPB * Electric vent valve () Mechanical shut-off assembly Indicates change. ) All ports are in NPTF. ) Apply two drops of threadlocker, ° apart. ) Torque from to ft-lbf (41 to 47 Nm). Indicates change.