American Standard IoT DetectLnk 607B322 Owner's Manual
American Standard IoT DetectLnk 607B322 Owner's Manual

American Standard IoT DetectLnk 607B322 Owner's Manual

Flush valve, piston-type for toilet & urinal

Advertisement

American Standard is devoted to making life,
in the heart of your home, better every day...
...so, thank you for inviting us in! With the very best in kitchen
and bathroom products, we are here to help make your life
happier, healthier and simpler. Our commitment to quality,
innovation and performance has made us part of your everyday
routine for nearly 150 years, and we look forward to being a
part of your life for many years to come.
Learn more at www.AmericanStandard.com
REGISTER YOUR WARRANTY
Try the easy-scan QR code to quickly enter
your information or find your product's
detailed warranty here:
www.AmericanStandard.com/warranty
Registering allows you to keep your product information
safe, and us the ability to contact you in the event of a
product recall or any news about your purchase.
And if ever you have a question or need help...?
Call us at 1-855-815-0004
M985166 EN (7/23)
607B322/607B501/607B505

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IoT DetectLnk 607B322 and is the answer not in the manual?

Questions and answers

Summary of Contents for American Standard IoT DetectLnk 607B322

  • Page 1 American Standard is devoted to making life, in the heart of your home, better every day… …so, thank you for inviting us in! With the very best in kitchen and bathroom products, we are here to help make your life happier, healthier and simpler.
  • Page 2: Inside The Box

    File Hex Wrench Solder & Torch NOTE TO INSTALLER: Please give this manual to the customer after installation. To learn more about American Standard Selectronic Products visit our website at: ® www.americanstandard-us.com or e-mail us at: ASdetectlnk@lixil.com For Parts, Service, Warranty or other Assistance,...
  • Page 3: Installation Instructions

    WALL THICKNESS Top Spud Fixtures 389 x 265 mm (15-5/16" x 10-3/8") FINISHED WALL ROUGH OPENING FOR BOX CAUTION: Use only American Standard 15˚ supplied transformers and cable sets. SENSOR Using non-AS supplied cables, or cutting, DETECTION ZONE splicing or modifying any components will 400 -800 mm void the warranty.
  • Page 4 FLUSH VALVE INSTALLATION INSTALL WALL BOX Fig. 3 (TOP SPUD FIXTURE ILLUSTRATED) 1. Frame out a 389 mm x 265 mm (15-5/4" X 10-3/8") 389 mm ROUGH OPENING IN WALL (15-5/16") rough opening in wall for the WALL BOX (1) at the LEVEL dimension shown.
  • Page 5 INSTALL VACUUM BREAKER AND FLUSH CONNECTIONS Note: Toilet or urinal graphics may vary depending on model. Fig. 6 1. Place the SPUD FLANGE (1) over the spud on the Fixture. 2. Place FRICTION WASHER (3) and SEAL WASHER (4) inside SPUD COUPLING NUT (2) and thread onto Spud.
  • Page 6 INSTALL FLUSH VALVE 1. Insert the side ADJUSTABLE TAILPIECE (1) on the FLUSH VALVE (2) into the STOP VALVE (3). Lubricate the TAILPIECE O-RING (4) with water if necessary. Thread the COUPLING NUT (5) onto the STOP VALVE (3) and tighten lightly. Important: Do not use lubricants (other than water) or any type of thread sealing paste or tape.
  • Page 7: Electrical Installation

    Fig. 9 ELECTRICAL INSTALLATION PWRX POWER KIT (PK00.WRK) Connect one end of the 27" EXTENSION CABLE (1) to a SENSOR CABLE (2). Connect the other end of the 27" EXTENSION CABLE (1) to the SOLENOID CABLE (3). 2. Connect BATTERY (6) to available SENSOR CABLE (5) Fig.
  • Page 8 HARD-WIRED VERSION (PK00.HAC POWER KIT) Connect one end of the first 27" EXTENSION CABLE (1) to SENSOR CABLE (5). Connect the other end of the 27" EXTENSION CABLE (1) to the SOLENOID CABLE (3). Connect the second 27" EXTENSION CABLE (4) to the BACK-UP BATTERY KIT (10), and the other end of the 27"...
  • Page 9 7. Plug in AC power supply into wall outlet once all daisy-chain unit connections have been made. CAUTION: Use only American Standard supplied transformers and cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components will void the warranty.
  • Page 10: Maintenance

    MAINTENANCE INSTALL NEW BATTERY Remove the COVER PLATE ( ) by removing Fig. 13 the four SCREWS ( Disconnect the OLD BATTERY (3) and replace with new battery. Install COVER PLATE ( Fig. 13a REPLACE BACK-UP BATTERY KIT FOR AC VERSION Remove old back-up battery by disconnecting the two wires.
  • Page 11 ADJUST STOP VALVE IMPORTANT: To avoid overflowing, the STOP VALVE (3) must never be opened to the point where the flow from the valve exceeds the flow capacity of the fixture. Valve is designed to provide stated flush volume with a 25 GPM flow rate.
  • Page 12 SET DETECTION RANGE (IF REQUIRED) 1. Once the device is paired, you may edit the settings by navigating to Device Management screen and finding the DEVICE CARD (1). You must be in Bluetooth range to the device. 2. Press on the DEVICE CARD (1) and scroll down to find the CONNECT (2) button.
  • Page 13 TROUBLESHOOTING: TOILET/URINAL FLUSH VALVE PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION Stop valve is closed. Open stop valve. Supply valve is closed. Open supply valve. Battery/The electric wire(s) is not Connect the wires. connected. Sensor lens is dirty. Clean lens. Remove the reflective surface from in front Reflective surface in front of sensor.
  • Page 14 TROUBLESHOOTING: TOILET/URINAL FLUSH VALVE CONT’D PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION Adjust the control stop for quiet operation Control stop is not adjusted for quiet keeping in mind the fixture evacuation operation. requirements. Check noise created by fixture by placing a cover over the bowl opening to separate Fixture is contributing to noise.
  • Page 15 APPENDIX A Supplier’s Declaration of Conformity 47 CFR § 2.1077 Compliance Information Unique Identifier: IoT Detectlnk TPS/UPS and 607B322 / 607B501 / 607B505 Responsible Party : AS America, Inc. d/b/a LIXIL Americas Address : AS America, Inc. d/b/a LIXIL Americas 865 Centennial Ave.
  • Page 16: Tell Us What You Think

    Register your sink at www.americanstandard.com. Please save your proof of purchase (sale receipt). If you need assistance or do not have access to our website, please contact American Standard Customer Care at: (800) 442-1902. An American Standard representative will assist in completing the warranty registration.

This manual is also suitable for:

Iot detectlnk 607b501Iot detectlnk 607b505

Table of Contents