THANK YOU We appreciate the trust and confidence you have placed in Everbilt through the purchase of this sump pump. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs. Thank you for...
Safety Information (continued) OVERLOAD PROTECTION WARNING: Do not use if the pump is damaged. If the pump is damaged, have it inspected by an authorized This pump has a built in thermal protection switch. The pump service center. stops if an overload condition occurs. The motor restarts automatically after it has cooled down WARNING: Make sure that electric connections are protected from flooding.
This pump is suitable to pump rain water and also can be used both for permanent and temporary installation. The pump can be placed in a sump pit to pump rain water containing suspended solid particles 3/8 in. for EPC50-HDC, 3/16 in. for EPP33-HDC, or less in diameter.
Pre-Installation (continued) PACKAGE CONTENTS Part Description Quantity Pump Float assembly Spare float assembly parts MATERIALS REQUIRED (NOT INCLUDED) Before using this pump, ensure you have the following items: Inlet and Thread discharge Check valve PVC glue Sump basin sealant tape piping HOMEDEPOT.COM Please contact 1-844-883-1872 for further assistance.
Assembly Preparing the pump Attaching the float assembly □ □ Remove the upper rubber grommet (1) from the float Insert the top of the float assembly (B) in the switch arm assembly (B). hole. Slide the upper rubber grommet (1) over the end of the float assembly (B) to hold the float assembly in place.
Installation Preparing a pump basin Placing the pump in a basin □ □ The pump must be installed in a suitable basin (not Place the pump (A) on a hard surface inside the sump included). The basin must be a maximum of 24 in. deep basin.
Operation Connecting power and testing Operating the pump pump operation □ □ Plug the pump power cord plug into a 120V GFCI power The pump will start automatically when the water level outlet. raises to the appropriate depth to activate the switch. To test the pump, pour water into the sump until the pump activates.
Troubleshooting WARNING: Before servicing a pump, always shut off the main power breaker and then unplug the pump. Under flooded conditions, make sure you are not standing in water and that you are wearing insulated protective sole shoes. Contact your local electric company or a qualified licensed electrician for disconnecting electrical service prior to pump removal.
Replacement Parts Number Description Part Number Base w/screw – EPP 091PED014 Float rod retainer 091PED007 Float washer 091PED010 On/Off Switch 091PED005...
Page 11
Questions, problems, missing parts? Before returning to the store, call Everbilt Customer Service 8 a.m. - 6 p.m., EST, Monday-Friday 1-844-883-1872 HOMEDEPOT.COM Retain this manual for future use.
Need help?
Do you have a question about the EPP33-HDC and is the answer not in the manual?