Download Print this page

Extron electronics UCS SW 313 Setup Manual page 3

Advertisement

UCS SW 313 • Setup Guide (Continued)
LAN port (see
figure 1
G
an RJ‑45 connector.
Default LAN port settings (if DHCP is not enabled):
Rear panel LAN IP address — 192.168.254.254
Subnet mask — 255.255.255.0
Gateway — 0.0.0.0
DNS — 127.0.0.1
Front panel USB-C port IP address — 203.0.113.22 at port 22023
Username — admin
Password — The product unit serial number. If an absolute system reset (for example, the
is performed, all passwords on this device are reset to extron.
NOTES:
• DHCP is disabled by default.
• If the UCS is set as a DHCP client and cannot locate a DHCP server, the port is set to a link local address.
• All Ethernet interfaces on the UCS SW 313 support up to 10/100/1000 Mbps (Gigabit Ethernet).
To wire the LAN connector (see figure 2):
Use a straight‑through cable for connection to a switch, hub, or router.
Use a crossover cable or a straight‑through cable for connection directly to a PC.
Pins:
12345678
RJ-45
Connector
Insert Twisted
Pair Wires
Figure 2. 
Wiring for Ethernet Control
Contact/Tally ports — (Optional) Wire a push‑button switch or other contact closure device to pin C (contact, see
H
image below, right) and pin G (ground, G) of the 2‑pole connectors (see the image below right). These ports are configured via
PCS or SIS commands.
To make input selections via contact closure, short the C pin of each port momentarily to the G (ground) pin (
switching occurs immediately on contact, and not on the release.
Alternatively, wire a Show Me (SM) cable to the C and T pins.
The contact closure ports have the following functions:
Port Number Function
1
2
3
Ports 1 - 3 — (See
exclusive input group to allow for input switching via SM cables. The selected input tally lights steadily when displayed, or
blinks when muted. Optionally, successive contact closures of the current input can be configured to toggle A/V mute or
output sync mute.
If None is selected, contact events broadcast unsolicited SIS responses for action via external control system. Tally ports
are configured via an external control system.
on page 2) — Connect the switcher to an active network using an Ethernet cable terminated with
Straight-through Cable
(for connection to a switch, hub, or router)
End 1
End 2
Pin
Wire Color
Pin
Wire Color
1
white-orange
1
white-orange
2
orange
2
orange
3
white-green
3
white-green
4
blue
4
blue
5
white-blue
5
white-blue
6
green
6
green
7
white-brown
7
white-brown
8
brown
8
brown
TIA/EIA-T568B
T568B
Pin Number
Input 1
4
5
Input 2
G
Input 3
in the Contact/Tally ports diagram, above right) These ports can be configured as a mutually
1
Crossover Cable
(for direct connection to a PC)
End 1
End 2
Pin
Wire Color
Pin
Wire Color
1
white-orange
1
white-green
2
orange
2
green
3
white-green
3
white-orange
4
blue
4
blue
5
white-blue
5
white-blue
6
green
6
orange
7
white-brown
7
white-brown
8
brown
8
brown
T568B
T568A
Function
AUX
AUX
Ground
E
]
ZQQQ
SIS command)
2
5
1 1 1
CONTACT/TALLY
1
2
3
4
5
C T
C T
C T
C T
C T +V G
2
2 2
3 3 3
in the
). Input
5
5 5
4 4
4
3

Advertisement

loading