Advertisement

Quick Links

Operating Instructions
Manual
IDEAL Air Blaster
Smart Ag
© AGCO 2024
Original Operating Instructions Manual
December 2024
ACX5606620
NA
English

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IDEAL Air Blaster and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AGCO IDEAL Air Blaster

  • Page 1 Operating Instructions Manual IDEAL Air Blaster December 2024 Smart Ag ACX5606620 © AGCO 2024 Original Operating Instructions Manual English...
  • Page 3: How To Use This Manual

    You must read this manual before you operate or do work on the machine. If more assistance is necessary, you should speak to your AGCO dealer. This manual is only applicable to the models specified in the build of material.
  • Page 4 IDEAL Air Blaster ACX5606620...
  • Page 5: Table Of Contents

    Table of Contents IDEAL Air Blaster Operation ..........................7 Operation ........................9 Quick Guide ......................10 How to utilize the Control Unit ................12 Installation ..........................13 Installation........................ 15 How to connect the wiring harness to the valve connector ......16 Fitting for the air tank ....................
  • Page 6 Table of contents IDEAL Air Blaster ACX5606620...
  • Page 7: Operation

    Table of contents 1 Operation Operation ..........................9 Quick Guide........................10 How to utilize the Control Unit..................12 IDEAL Air Blaster ACX5606620...
  • Page 8 Table of contents IDEAL Air Blaster ACX5606620...
  • Page 9: Operation

    By scanning the QR code below you will get directly access to resources including videos showing how to operate and adjust the system. Fig. 1 IDEAL Air Blaster ACX5606620...
  • Page 10: Quick Guide

    The short pipes should be placed on the feeder house during transport mode and when picking up the header and connecting the PTO. Fig. 2 After the header is attached lift the short pipes from the feeder house. IDEAL Air Blaster ACX5606620...
  • Page 11 1 Operation Fig. 3 Place the short pipes on the header, example like in the picture below. Fig. 4 IDEAL Air Blaster ACX5606620...
  • Page 12: How To Utilize The Control Unit

    Wear ear and eye production. CAUTION: Never activate the push button when bystanders are close to the feeder house. Release of pressurized air can result in dust in eyes and loud sounds. Wear ear and eye production. IDEAL Air Blaster ACX5606620...
  • Page 13: Installation

    Safety Stickers........................19 Special instructions for Dust Ejector feeder houses..........20 Fault Finding ........................21 2.6.1 The system is not operating when activating ..............21 2.6.2 No air is coming out when activating................22 2.6.3 Leaking and Low pressure..................22 IDEAL Air Blaster ACX5606620...
  • Page 14 Table of contents IDEAL Air Blaster ACX5606620...
  • Page 15: Installation

    DANGER: Tripping Hazard Be careful lifting your feet while working Fig. 1 on the feeder house. The installed hoses and pipes can cause a tripping hazard. IDEAL Air Blaster ACX5606620...
  • Page 16: How To Connect The Wiring Harness To The Valve Connector

    How to connect the wiring harness to the valve connector T0035067977 Follow these steps to connect the wiring harness to the valve connector: Procedure Pass the end of the wire with the loose ends through the grommet and the plastic cap. Fig. 2 IDEAL Air Blaster ACX5606620...
  • Page 17 2 Installation Connect the positive wire to terminal 1. Connect the ground wire to terminal 2. Fig. 3 Reassemble everything. Make sure to include the screw and sealing. Fig. 4 IDEAL Air Blaster ACX5606620...
  • Page 18: Fitting For The Air Tank

    2 Installation Fitting for the air tank T0035067981 Make sure to add this fitting (ACX4979990) to the air tank. Fig. 5 IDEAL Air Blaster ACX5606620...
  • Page 19: Safety Stickers

    2 Installation Safety Stickers T0035067987 Don’t forget to place the stickers from the kit on your combine and your feeder house to keep you and your staff safe. Fig. 6 IDEAL Air Blaster ACX5606620...
  • Page 20: Special Instructions For Dust Ejector Feeder Houses

    Fig. 7 Cut 540 mm (21.3 in) off the long pipe cover (part ACX4716730) as shown in the picture. After cutting, smooth any sharp edges for safety. Paint the cut area to prevent rust. Fig. 8 IDEAL Air Blaster ACX5606620...
  • Page 21: Fault Finding

    If it doesn’t click: Check connection between box and valve. If connection/wire is not damaged, solenoid or PCB might be broken. If it clicks: If it clicks, your electronics might be okay, see next capture for fault-finding on-air system. IDEAL Air Blaster ACX5606620...
  • Page 22: No Air Is Coming Out When Activating

    If there is a leaking issue where the to-connector is connected to the air hose underneath the ladder, please add a groom like shown below. Contact your dealer to get one for hose size ½ inch. Fig. 10 IDEAL Air Blaster ACX5606620...
  • Page 23: Maintenance And Service

    Table of contents 3 Maintenance and Service After Season........................25 Cleaning windows......................26 Attaching or Detaching Headers.................. 27 IDEAL Air Blaster ACX5606620...
  • Page 24 Table of contents IDEAL Air Blaster ACX5606620...
  • Page 25: After Season

    3 Maintenance and Service After Season T0035068056 Drain the air tank for water before storing the machine after season IDEAL Air Blaster ACX5606620...
  • Page 26: Cleaning Windows

    Always be careful when climbing on a combine, as dust can cause surfaces to be slippery. DANGER: Tripping Hazard Be careful lifting your feeds while working on the feeder house. The installed hoses and pipes can cause a tripping hazard. IDEAL Air Blaster ACX5606620...
  • Page 27: Attaching Or Detaching Headers

    DANGER: The machines engine must be shut off and feeder house lowered when installing the system to avoid any crushing of humans. Lifting or lowering the feeder house during installation can cause fatal injury or death. IDEAL Air Blaster ACX5606620...
  • Page 28 3 Maintenance and Service IDEAL Air Blaster ACX5606620...
  • Page 29: Safety

    Table of contents 4 Safety Safety Instructions ......................31 IDEAL Air Blaster ACX5606620...
  • Page 30 Table of contents IDEAL Air Blaster ACX5606620...
  • Page 31: Safety Instructions

    Lifting or lowering the feeder house during installation can cause fatal injury or death. DANGER: Be careful lifting your feet while working on the feeder house. The installed hoses and pipes can cause a tripping hazard. IDEAL Air Blaster ACX5606620...
  • Page 32 4 Safety IDEAL Air Blaster ACX5606620...
  • Page 33: Waste Disposal

    Table of contents 5 Waste disposal Waste disposal ......................... 35 IDEAL Air Blaster ACX5606620...
  • Page 34 Table of contents IDEAL Air Blaster ACX5606620...
  • Page 35: Waste Disposal

    Speak with the local authorities on the correct procedure to discard of the waste. Fig. 1 The control elements of the IDEAL Air Blaster system contain special materials and alloys. Please make sure that all disposal of the components is considered as electric waste.
  • Page 36 5 Waste disposal IDEAL Air Blaster ACX5606620...
  • Page 37: Index

    Leaking and Low pressure........22 No air is coming out when activating ......22 Operation..............9 Quick Guide ............10 Safety ..............31 Safety Stickers ............19 The system is not operating when activating ....21 Waste disposal ............35 IDEAL Air Blaster ACX5606620...
  • Page 38 © AGCO Corporation, 2024. All rights reserved. ACX5606620 (English) December 2024...

Table of Contents