Summary of Contents for Dometic ZAMP SOLAR Legacy Black KIT 1025
Page 1
KIT 1025 Legacy Black 190 Watt Cinder 40 Deluxe Kit INSTALLATION INSTRUCTIONS INSTALLATION SAFETY - Inspect the installation area for safety hazards. - Be sure to remove all metal such as rings and other jewelry. - Disconnect all power sources and ensure solar panels are completely covered by a box or blanket until installation is done.
Page 2
Set panel with feet attached on the roof to 2 inch clear area locate the best mounting position. Position Example top panel at least 2 inches away from any other roof mounting locations items. Mark the locations where your feet connect with the roof, then set the panel aside.
Using a 1-inch step bit, create the opening for the wire harness to pass through by removing the plastic “wafer” on the base of the roof cap. *There are alternative ports on the left and right sides to the interior of the cap for use in different scenarios which allow for more customization.
Page 4
B - MOUNTING WITH VHB TAPE B-08 Find an area on the roof to mount your roof cap. Drill a hole no smaller than 1/2 Inch to allow for wiring access. (Deburring the hole is recommended.) Once the hole is made, feed the wires through from the inside and secure them respectively to the positive and negative terminals housed within the roof cap.
Page 5
12 Locate the terminals on the bottom of your charge controller. 13 Connecting Battery Connect the negative and positive wires (controller to battery) to the corresponding terminals on the bottom of your charge controller labeled “battery” using a flat head screwdriver.
Page 6
16 Attach the fuse block assembly to the positive terminal on the battery. Place the fuse block on the terminal and slide the flat washer over the post. Attach the positive wire from the controller on top of the washer, followed by the split washer and security nut.
Page 7
20 Install the breaker to an easy access spot near the controller. Connect the positive wire from the controller to the circuit breaker. 20 Install the black stub post in an easy to access spot. Connect the negative wire from the charge controller to the black stub post.
Follow your manual to set up your battery profiles. Please contact us with any questions or concerns you have. TECH SUPPORT 541-728-0924 customer.support.zampsolar@dometic.com Solar panel Roof port cap (connect wiring) House battery Charge controller System Diagram...
Need help?
Do you have a question about the ZAMP SOLAR Legacy Black KIT 1025 and is the answer not in the manual?