  • Page 1 Instructions for use KaVo Lumina...
  • Page 2 Distributed by: Manufacturer: KaVo Dental GmbH KaVo Dental GmbH Bismarckring 39 Bismarckring 39 88400 Biberach 88400 Biberach Germany Germany Phone +49 7351 56-0 www.kavo.com Fax +49 7351 56-1488...
  • Page 3: Table Of Contents

    2.5 Disposal........................9 3 Description of the product ....................11 3.1 General information ...................... 11 3.2 KaVo Lumina operating light ..................12 3.3 Dimensions and swing ranges ..................12 3.4 Rating plates ........................ 14 3.5 Purpose – Proper use ....................15 3.6 Technical specifications and requirements................
  • Page 4 Instructions for use KaVo Lumina Table of contents 5.1 General care instructions ....................29 5.2 General reprocessing instructions ................... 29 5.2.1 Cleaning and disinfection of the light, cover and mirror ........30 5.3 Cleaning the silicone handles..................30 5.3.1 Thermodisinfect the silicone handles ..............30 5.3.2...
  • Page 5: User Instructions

    1 User instructions | 1 User instructions Dear user, Congratulations on purchasing this KaVo quality product. By following the notes below you will be able to work smoothly, economically and safely. © Copyright by KaVo Dental GmbH All other trademarks are property of their respective owners.
  • Page 6: Hazard Levels

    Instructions for use KaVo Lumina 1 User instructions | HIBC Code EAC conformity mark (Eurasian Conformity) Transportation and storage conditions (temperature range) Transportation and storage conditions (air pressure) Transportation and storage conditions (Humidity) Protect from moisture (Keep dry) Protect from impact...
  • Page 7: Terms And Conditions Of Warranty

    1.1 Terms and conditions of warranty KaVo provides the final customer with a warranty that the product cited in the transfer form will function properly and guarantees zero defects in the material or processing for a period of 12 months from the date of purchase, subject to...
  • Page 8 Terms and Conditions, Art. 28). Outside Germany NOTE KaVo shall not be held liable for damage arising from transportation. The shipment must be checked on arrival. If the packaging is visibly damaged on delivery, please proceed as follows: 1. The recipient of the package must record the loss or damage on the delivery receipt.
  • Page 9: Safety

    Dispose of and recycle the packaging appropriately in accordance with current packaging law, employing waste management / recycling companies. Comply with the comprehensive return system. KaVo has had its packaging licensed for this purpose. Please comply with the regional public waste-disposal system.
  • Page 10 Any waste produced must be recycled or disposed of in strict compliance with all applicable national regulations in a manner which is safe for both people and the environment. If you have any questions regarding the proper disposal of the KaVo product, please contact the KaVo branch office. NOTE A recycling pass can be downloaded from www.kavo.com.
  • Page 11: Description Of The Product

    ▪ ESTETICA E50 Life ▪ Primus 1058 Life ▪ KaVo uniQa ▪ KaVo amiQa ▪ ESTETICA E30 The KaVo Lumina can be mounted in the following additional positions/to the following equipment: ▪ On the ceiling ▪ CENTRO support system ▪ DSEclinical E50 Life "Intended use"...
  • Page 12: Kavo Lumina Operating Light

    Instructions for use KaVo Lumina 3 Description of the product | 3.2 KaVo Lumina operating light 3.2 KaVo Lumina operating light ① Mounting post ② Swivel arm Alternative for Centro (adapter 150, adapter 400) ③ Spring arm ④ Handles ⑤ Mirror (optional) ⑥...
  • Page 13 Instructions for use KaVo Lumina 3 Description of the product | 3.3 Dimensions and swing ranges CAUTION Danger of crushing between the swivel arm and the light mounting post Injury and damage 4 Always move or swivel the operating light with great care.
  • Page 14: Rating Plates

    Instructions for use KaVo Lumina 3 Description of the product | 3.4 Rating plates 3D joint (optional) Dimensions and angle 3.4 Rating plates There is one rating plate for the treatment centre and, in the case of ceiling mounting, one additional rating plate for the ceiling mounting kit, The rating plate of the ceiling mounting kit is fastened to the ceiling.
  • Page 15: Purpose - Proper Use

    EC directives. 3.5 Purpose – Proper use Product description The dental treatment lights from KaVo allow to illuminate the human oral cavity during general dental procedures. The operating lamp is specified as equipment for dentistry according to ISO 9680.
  • Page 16: Technical Specifications And Requirements

    No special restrictions regarding the population. Restrictions must be determ- ined by trained medical personnel - e.g. disabled (mental). Place of installation: KaVo dental treatment lights may only be used in medical rooms. 3.6 Technical specifications and requirements Photobiological safety (IEC 62471)
  • Page 17: Transportation And Storage Conditions

    Instructions for use KaVo Lumina 3 Description of the product | 3.7 Accessories Transportation and storage conditions Ambient temperature -20 to +55 C / -4 to +131°F Humidity limitation 5% to 95% non-condensing Atmospheric pressure limitation 700 hPa to 1060 hPa (10 psi to 15 psi) 3.7 Accessories...
  • Page 18: Operation

    4 Do not use the operating light in combination with a laser. Reduce third- party light in use with the operating light. The KaVo Lumina operating light can either be operated with the aid of ges- tures, via the integrated sensor, or via the operating buttons on the treatment unit.
  • Page 19: Operating Of Treatment Unit With Touch Display

    Instructions for use KaVo Lumina 4 Operation | 4.1 Operating of treatment unit with touch display ▪ Dimmed light: approx. 5,200 Kelvin; composites can be subject to prema- turel curing. 4.1 Operating of treatment unit with touch display 4.1.1 Switching the operating light on / off 4 Press the "Treatment light"...
  • Page 20: Setting The Brightness Of The Light In Normal Light And In Mode

    Instructions for use KaVo Lumina 4 Operation | 4.1 Operating of treatment unit with touch display ð This causes the settings options of the operating light to be displayed. 4 Press the "Dimmer mode" selection button to switch between COMPOshape and dimmer mode.
  • Page 21: Spalight Mode

    Instructions for use KaVo Lumina 4 Operation | 4.1 Operating of treatment unit with touch display ð Reducing the sensor sensitivity means that the gesture recognition dis- tance is reduced. 4.1.6 SPAlight mode In SPAlight mode, soothing lighting in line with modern colour psychology en- sures a relaxed atmosphere before and between treatments.
  • Page 22: Operation Of E50 Life And Dse Clinical E50 Life

    Instructions for use KaVo Lumina 4 Operation | 4.2 Operation of E50 Life and DSE Clinical E50 Life 4.2 Operation of E50 Life and DSE Clinical E50 Life 4.2.1 Switching the operating light on / off 4 Press the "Treatment light" button.
  • Page 23: Setting The Brightness Of The Light In Normal Light And In Mode

    Instructions for use KaVo Lumina 4 Operation | 4.2 Operation of E50 Life and DSE Clinical E50 Life 4 Press the "Back" and "Forward" keys to select the desired option (1 through 14). 4 Click through to option 12: Option 12: Setting dimming mode for the LED lamp NOTE The "Set dimming mode for LED lamp"...
  • Page 24: Operation Of 1058 Life

    Instructions for use KaVo Lumina 4 Operation | 4.3 Operation of 1058 Life 4.3 Operation of 1058 Life 4.3.1 Switching the operating light on / off 4 Press the "Treatment light" button. 4 Wipe with your hand in front of the sensor.
  • Page 25: Operation Of E30

    Instructions for use KaVo Lumina 4 Operation | 4.4 Operation of E30 4.4 Operation of E30 4.4.1 Switching the operating light on / off 4 Press the "Treatment light" button. 4 Wipe with your hand in front of the sensor.
  • Page 26: Setting The Brightness Of The Light In Normal Light And In Mode

    Instructions for use KaVo Lumina 4 Operation | 4.4 Operation of E30 ð Option 1 "Number of users" or most recently used option is displayed. 4 Press the "Back" and "Forward" keys to select the desired option (1 through 14).
  • Page 27: Operating Of Ceiling Mounting

    Instructions for use KaVo Lumina 4 Operation | 4.5 Operating of ceiling mounting 4.5 Operating of ceiling mounting 4.5.1 Switching the operating light on / off 4 Wipe with your hand in front of the sensor. 4.5.2 Switching COMPOshape mode/dimmer mode on/...
  • Page 28: Operation Of The 3D Joint (Optional)

    Instructions for use KaVo Lumina 4 Operation | 4.6 Operation of the 3D joint (optional) 4.6 Operation of the 3D joint (optional) 4 Turn the switching ring to the left until it snaps into place. ð Operating light can be rotated 45° to the left or 45° to the right.
  • Page 29: Processing Methods Din En Iso 17664-1 / 17664-2

    Instructions for use KaVo Lumina 5 Processing methods DIN EN ISO 17664-1 / 17664-2 | 5.1 General care instructions 5 Processing methods DIN EN ISO 17664-1 / 17664-2 5.1 General care instructions CAUTION Product damage or contamination due to improper disinfection.
  • Page 30: Cleaning And Disinfection Of The Light, Cover And Mirror

    Instructions for Use of the washer disinfector. In order to prevent impairment of the KaVo medical device, make sure that the inside and outside of the device is dry after the end of the cycle. Then service the product in ac- cordance with the product-specific care instructions.
  • Page 31 Instructions for use KaVo Lumina 5 Processing methods DIN EN ISO 17664-1 / 17664-2 | 5.3 Cleaning the silicone handles Select a suitable process from the following sterilisation processes (depending on the available steriliser): ▪ Steriliser with triple pre-vacuum: – at least 3 minutes at 134...
  • Page 32: Additional Equipment And Assembly Kits

    Instructions for use KaVo Lumina 6 Additional equipment and assembly kits 6 Additional equipment and assembly kits The operating light can be equipped with the following assembly kits: ▪ 3D joint ▪ Silicone handle ▪ Mirror ▪ Ceiling mounting kit...
  • Page 33: Safety Check - Test Instructions

    Instructions for use KaVo Lumina 7 Safety check - Test instructions 7 Safety check - Test instructions see also: technician's instructions and assembly instructions for the light and the treat- ment unit. 33 / 40...
  • Page 34: Troubleshooting

    Instructions for use KaVo Lumina 8 Troubleshooting 8 Troubleshooting Malfunction Cause Remedy Nothing works. Main switch is off. 4 Turn on the main switch. 4 Unplug the unit from the mains. Main service fuse inter- rupted the electric cir- 4 For ceiling mounting, check and replace, if cuit.
  • Page 35: Information Concerning The Electromagnetic Compatibility According To En Iec

    Instructions for use KaVo Lumina 9 Information concerning the electromagnetic compatibility according to EN IEC 60601-1-2 | 9.1 Operating environ- ment and EMC warning notes 9 Information concerning the electromagnetic compatibility according to EN IEC 60601-1-2 9.1 Operating environment and EMC warning notes This product is neither life-sustaining nor coupled to the patient.
  • Page 36 Instructions for use KaVo Lumina 9 Information concerning the electromagnetic compatibility according to EN IEC 60601-1-2 | 9.2 Results of the electromagnetic tests Requirement Class / test level Immunity to electromagnetic interference DIN EN 61000-4-2 VDE 0847-4-2 / 12.2009 Electrostatic discharge (ESD) Atmospheric discharge ±...
  • Page 37 Instructions for use KaVo Lumina 9 Information concerning the electromagnetic compatibility according to EN IEC 60601-1-2 | 9.2 Results of the electromagnetic tests Requirement Class / test level at 45° steps from 0°- 315° 0 %/ 1 cycle 70 %/ 25 cycles...