Summary of Contents for KaVo SMARTtorque LUX S619 L

  • Page 1 Instructions for use SMARTtorque LUX S619 L - 1.008.1641 SMARTtorque Mini LUX S615 L - 1.008.1643 SMARTtorque S619 C - 1.008.1642 Always be on the safe side.
  • Page 2 Distributed by: Manufacturer: KaVo Dental GmbH Kaltenbach & Voigt GmbH Bismarckring 39 Bismarckring 39 D-88400 Biberach D-88400 Biberach Phone +49 7351 56-0 www.kavo.com Fax +49 7351 56-1488...
  • Page 3: Table Of Contents

    Instructions for use SMARTtorque LUX S619 L - 1.008.1641 SMARTtorque Mini LUX S615 L - 1.008.1643 SMARTtorque S619 C - 1.008.1642 Table of contents Table of contents User instructions ............................2 Safety ................................ 3 Description of safety instructions ..................... 3 Safety instructions ...........................
  • Page 4: User Instructions

    Instructions for use SMARTtorque LUX S619 L - 1.008.1641 SMARTtorque Mini LUX S615 L - 1.008.1643 SMARTtorque S619 C - 1.008.1642 1 User instructions 1 User instructions Dear User Congratulations on purchasing this KaVo quality product. By following the instruc‐...
  • Page 5: Safety

    Instructions for use SMARTtorque LUX S619 L - 1.008.1641 SMARTtorque Mini LUX S615 L - 1.008.1643 SMARTtorque S619 C - 1.008.1642 2 Safety | 2.1 Description of safety instructions 2 Safety 2.1 Description of safety instructions Warning symbol Structure DANGER The introduction describes the type and source of the hazard.
  • Page 6 Instructions for use SMARTtorque LUX S619 L - 1.008.1641 SMARTtorque Mini LUX S615 L - 1.008.1643 SMARTtorque S619 C - 1.008.1642 2 Safety | 2.2 Safety instructions WARNING Hazard from contraindication. If the soft tissue in the oral cavity is injured, the compressed air may enable sep‐...
  • Page 7: Product Description

    Instructions for use SMARTtorque LUX S619 L - 1.008.1641 SMARTtorque Mini LUX S615 L - 1.008.1643 SMARTtorque S619 C - 1.008.1642 3 Product description | 3.1 Purpose – Proper use 3 Product description Mat. no. 1.008.1641 SMARTtorque LUX S619 L ( Mat.
  • Page 8: Technical Specifications

    Instructions for use SMARTtorque LUX S619 L - 1.008.1641 SMARTtorque Mini LUX S615 L - 1.008.1643 SMARTtorque S619 C - 1.008.1642 3 Product description | 3.2 Technical Specifications 3.2 Technical Specifications SURGtorque S459 L Minimal drive pressure 2.1 bar (30 psi) Drive pressure 2.1 to 4.2 bar (30 to 61 psi)
  • Page 9: Start Up And Shut Down

    Instructions for use SMARTtorque LUX S619 L - 1.008.1641 SMARTtorque Mini LUX S615 L - 1.008.1643 SMARTtorque S619 C - 1.008.1642 4 Start up and shut down | 4.1 Mount the MULTIflex (LUX) / MULTIflex LED coupling 4 Start up and shut down WARNING Hazard from non-sterile products.
  • Page 10: Checking The Pressures

    Instructions for use SMARTtorque LUX S619 L - 1.008.1641 SMARTtorque Mini LUX S615 L - 1.008.1643 SMARTtorque S619 C - 1.008.1642 4 Start up and shut down | 4.3 Checking the pressures 4.3 Checking the pressures CAUTION Compressed air connection on devices.
  • Page 11: Operation

    Instructions for use SMARTtorque LUX S619 L - 1.008.1641 SMARTtorque Mini LUX S615 L - 1.008.1643 SMARTtorque S619 C - 1.008.1642 5 Operation | 5.1 Attaching the medical device 5 Operation Note At the beginning of each workday, the water-conducting systems should be rinsed for at least 2 min.
  • Page 12: Removing The Milling Tool Or Diamond Grinder

    Instructions for use SMARTtorque LUX S619 L - 1.008.1641 SMARTtorque Mini LUX S615 L - 1.008.1643 SMARTtorque S619 C - 1.008.1642 5 Operation | 5.4 Removing the milling tool or diamond grinder. WARNING Use of unauthorised cutters or grinders. Injury to the patient or damage to the medical device.
  • Page 13: Troubleshooting

    Instructions for use SMARTtorque LUX S619 L - 1.008.1641 SMARTtorque Mini LUX S615 L - 1.008.1643 SMARTtorque S619 C - 1.008.1642 6 Troubleshooting | 6.1 Exchanging the O-rings on the coupling on the supply hose 6 Troubleshooting 6.1 Exchanging the O-rings on the coupling on the supply hose CAUTION Hazard from improper care of the O-rings.
  • Page 14: Reprocessing Methods According To Iso 17664

    Instructions for use SMARTtorque LUX S619 L - 1.008.1641 SMARTtorque Mini LUX S615 L - 1.008.1643 SMARTtorque S619 C - 1.008.1642 7 Reprocessing methods according to ISO 17664 | 7.1 Preparations at the site of use 7 Reprocessing methods according to ISO 17664 7.1 Preparations at the site of use...
  • Page 15: Manual Internal Cleaning

    Instructions for use SMARTtorque LUX S619 L - 1.008.1641 SMARTtorque Mini LUX S615 L - 1.008.1643 SMARTtorque S619 C - 1.008.1642 7 Reprocessing methods according to ISO 17664 | 7.3 Disinfection ▶ In order to prevent negative effects on the medical device, make sure that the...
  • Page 16: Manual External Disinfection

    Instructions for use SMARTtorque LUX S619 L - 1.008.1641 SMARTtorque Mini LUX S615 L - 1.008.1643 SMARTtorque S619 C - 1.008.1642 7 Reprocessing methods according to ISO 17664 | 7.3 Disinfection 7.3.1 Manual external disinfection KaVo recommends the following products based on material compatibility.
  • Page 17: Drying

    Instructions for use SMARTtorque LUX S619 L - 1.008.1641 SMARTtorque Mini LUX S615 L - 1.008.1643 SMARTtorque S619 C - 1.008.1642 7 Reprocessing methods according to ISO 17664 | 7.4 Drying 7.4 Drying Manual Drying ▶ Blow off the outside and inside with compressed air until water drops are no longer visible.
  • Page 18: Care With Kavo Sprayrotor

    Instructions for use SMARTtorque LUX S619 L - 1.008.1641 SMARTtorque Mini LUX S615 L - 1.008.1643 SMARTtorque S619 C - 1.008.1642 7 Reprocessing methods according to ISO 17664 | 7.5 Care products and systems - Servicing ▶ Remove the cutter or grinder, place the INTRA spray nipple tip in the opening and spray.
  • Page 19: Packaging

    Instructions for use SMARTtorque LUX S619 L - 1.008.1641 SMARTtorque Mini LUX S615 L - 1.008.1643 SMARTtorque S619 C - 1.008.1642 7 Reprocessing methods according to ISO 17664 | 7.6 Packaging Note Close the chuck service mode. Option 1: Place the dental handpieces in the QUATTROcare PLUS 2124 A, close the front door and start theservice procedure.
  • Page 20: Storage

    Instructions for use SMARTtorque LUX S619 L - 1.008.1641 SMARTtorque Mini LUX S615 L - 1.008.1643 SMARTtorque S619 C - 1.008.1642 7 Reprocessing methods according to ISO 17664 | 7.8 Storage ▶ Use according to the manufacturer's Instructions for Use.
  • Page 21: Tools

    Instructions for use SMARTtorque LUX S619 L - 1.008.1641 SMARTtorque Mini LUX S615 L - 1.008.1643 SMARTtorque S619 C - 1.008.1642 8 Tools 8 Tools Available from dental suppliers. Material summary Mat. no. Replacement rotor Standard X.XXX.XXXX Wrench Standard X.XXX.XXXX Instrument stand 2151 0.411.9501...
  • Page 22: Warranty Terms And Conditions

    Instructions for use SMARTtorque LUX S619 L - 1.008.1641 SMARTtorque Mini LUX S615 L - 1.008.1643 SMARTtorque S619 C - 1.008.1642 9 Warranty terms and conditions 9 Warranty terms and conditions The following warranty conditions apply to this KaVo medical device:...
  • Page 23 Instructions for use SMARTtorque LUX S619 L - 1.008.1641 SMARTtorque Mini LUX S615 L - 1.008.1643 SMARTtorque S619 C - 1.008.1642 9 Warranty terms and conditions Poland Czech KaVo Polska Sp.z.o.o. Republic KaVo CZ spol. s.r.o. UL. Pomorska 251 p.405...

Table of Contents