1. About this document 1.1. Scope These operating instructions apply to all CES-A-C5H-01-EX of version V1.0.X. These operating instructions, the document Safety information and any available data sheet form the complete user information for your device. Important! Make sure to use the operating instructions valid for your product version. Please contact the EUCHNER support team if you have any questions.
Ì EN IEC 60079-31 Ì The safety switch must be used only in conjunction with the designated CES actuators from EUCHNER. On the use of different actuators, EUCHNER provides no warranty for safe function. Important! Devices with ATEX rating may be operated only with actuators that also have an ATEX rating for the Ì...
Combination possible Key to symbols Combination not permissible NOTICE Approved connecting cables can be found at www.euchner.com. Enter the item number in the search Ì box and go to the Accessories tab. 3. Description of the safety function Devices from this series feature the following safety functions: Monitoring of the guard position (interlocking device according to EN ISO 14119)
Operating Instructions Non-Contact Safety Switch CES-A-C5H-01-EX 4. Explosion protection safety concept Safety switches series CES-A-C5H-01-EX can be used in potentially explosive atmospheres only if the associated housing guard is used. Important! In order to achieve the explosion protection stated, all the conditions in the operating instructions Ì...
Operating Instructions Non-Contact Safety Switch CES-A-C5H-01-EX 4.1. Additional notes on connection and mounting Generally observe the specifications of the EN IEC 60079-14 standard. Ì The specified type of protection ic applies only to the integrated reader module. The electrical circuits in the device con- Ì...
Operating Instructions Non-Contact Safety Switch CES-A-C5H-01-EX 6. General safety precautions Safety switches fulfill personnel protection functions. Incorrect installation or tampering can lead to fatal injuries to personnel. Check the safe function of the guard particularly after any setup work Ì...
Operating Instructions Non-Contact Safety Switch CES-A-C5H-01-EX 7. Function The safety switch monitors the position of movable guards. The safety outputs are switched on/off when the actuator is moved to/removed from the actuating range. The system consists of the following components: coded actuator (transponder with high coding level) and switch.
Operating Instructions Non-Contact Safety Switch CES-A-C5H-01-EX 7.3. Block diagram Coded Trans- actuator ponder Read head with Read head evaluation unit CES-A-.5 Pin assignment: Function Core color WH/white BN/brown Housing: GN/green 118 x 40 x 40 mm YE/yellow GY/gray PK/pink BU/blue...
Operating Instructions Non-Contact Safety Switch CES-A-C5H-01-EX 8. Changing the approach direction NOTICE Risk of damage to equipment as a result of trapped cables. Ì Make sure that the cables are not trapped or torn off when the approach direction is changed.
Operating Instructions Non-Contact Safety Switch CES-A-C5H-01-EX 9. Mounting WARNING On use in potentially explosive atmospheres, the following applies: Protection against mechanical effects on the switch: Ì - Mount the switch so that the rear of the housing is entirely covered in order to protect it from me- chanical damage through impact.
Page 14
Operating Instructions Non-Contact Safety Switch CES-A-C5H-01-EX Note the following points: Actuator and safety switch must be easily accessible for inspection and replacement. Ì Actuator and safety switch must be fitted so that Ì - the front faces are at the minimum operating distance 0.8 x S or closer when the guard is closed.
Operating Instructions Non-Contact Safety Switch CES-A-C5H-01-EX 10. Electrical connection WARNING Loss of the safety function due to incorrect connection. Not suitable for safety relays that implement short circuit monitoring with different potentials (0 V/24 V). Ì The voltage at +LA/+LB must correspond to the information in the technical data.
CAUTION Danger of explosion or malfunctions as a result of incorrect connecting cables. For connecting cables, the requirements in the following table apply. EUCHNER provides no warranty Ì for safe function in case of failure to comply with these requirements.
Operating Instructions Non-Contact Safety Switch CES-A-C5H-01-EX 10.5. Correct connection WARNING In the event of a fault, loss of the safety function due to incorrect connection. To ensure safety, both safety outputs (LA and LB) must always be evaluated. Ì To achieve category 4 according to EN ISO 13849-1, it is necessary to monitor the downstream Ì...
Operating Instructions Non-Contact Safety Switch CES-A-C5H-01-EX 10.6. Connection example Important! To achieve category 4 according to EN ISO 13849-1, it is necessary to monitor the downstream Ì contactors (not shown here). The example shows only an excerpt that is relevant for the connection of the CES system. The Ì...
Operating Instructions Non-Contact Safety Switch CES-A-C5H-01-EX 11. Setup 11.1. LED displays Color State Meaning illumi- Normal operation nated STATE green - Teach-in operation flashing (for further signal function, see chapter 12. System status table on page 22) illumi- yellow Valid actuator detected...
Operating Instructions Non-Contact Safety Switch CES-A-C5H-01-EX 11.2.2. Carrying out teach-in for a new actuator A maximum of 8 teach-in operations can be performed. The number of already completed teach-in operations is signaled by the flashing sequence of the STATE LED each time the power supply is connected (see 12. System status table on page 22, area Status indication).
Operating Instructions Non-Contact Safety Switch CES-A-C5H-01-EX 12. System status table LED indicator Output Output Operating mode State closed Normal operation, door closed Normal operation open Normal operation, door open open 4 Hz Initial setup after delivery, ready for first teach-in operation...
Operating Instructions Non-Contact Safety Switch CES-A-C5H-01-EX 13. Technical data NOTICE If a data sheet is available for this product, the information on the data sheet applies. 13.1. Safety switch CES-A-C5H-01-EX Read head and evaluation unit integrated in the normal housing Ì...
Operating Instructions Non-Contact Safety Switch CES-A-C5H-01-EX 13.1.1. Technical data for safety switch CES-A-C5H-01-EX Value Parameter Unit min. typ. max. Housing material PBT GF30 Dimensions Acc. to EN 60947-5-2 Weight Ambient temperature at U = 24 V DC °C Degree of protection...
Operating Instructions Non-Contact Safety Switch CES-A-C5H-01-EX 13.1.2. Typical system times Refer to the technical data for the exact values. Ready delay: After switch-on, the device carries out a self-test. The system is ready for operation only after this time. Turn-on time of safety outputs: The max. reaction time t is the time from the moment when the actuator is in the actu- ating range to the moment when the safety outputs switch on.
Operating Instructions Non-Contact Safety Switch CES-A-C5H-01-EX 13.2. Actuator CES-A-BPA-EX Cube-shaped design 40 x 40 mm Ì Dimension drawing for CES-A-BPA-EX - 0,25 CES-A-BPA-EX IP67 Active face Active face 2 safety screws M4 x 14 included 13.2.1. Technical data Value Parameter Unit min. typ.
Operating Instructions Non-Contact Safety Switch CES-A-C5H-01-EX 13.2.2. Typical operating distance Only in conjunction with actuator CES-A-BPA-EX on surface mounting. - 4 5 - 4 5 For a side approach direction for the actuator and read head, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.
Operating Instructions Non-Contact Safety Switch CES-A-C5H-01-EX 13.3. Actuator CES-A-BBA-EX Cube-shaped design 42 x 25 mm Ì Dimension drawing for CES-A-BBA-EX CES-A-B BA-EX 32 ±0,1 Active face Active face 2 M4 x 14 safety screws included 13.3.1. Technical data Value Parameter Unit min. typ. max. Housing material...
Operating Instructions Non-Contact Safety Switch CES-A-C5H-01-EX 13.3.2. Typical operating distance Only in combination with actuator CES-A-BBA-EX. - 3 0 - 3 0 For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm must be maintained so that the actuating range of the side lobes is not entered.
Explosion Protection Directive (ATEX) 2014/34/EU Ì The EU declaration of conformity can be found at www.euchner.com. Enter the order number of your device in the search box. The document is available under Downloads. (translation of the original operating instructions) 2110182-13-04/25...
Page 31
Operating Instructions Non-Contact Safety Switch CES-A-C5H-01-EX 2110182-13-04/25 (translation of the original operating instructions)
Need help?
Do you have a question about the CES-A-C5H-01-EX and is the answer not in the manual?
Questions and answers