12.2 Possible Error Messages
Error message
Card off line
Scanner not connected
Scanner X error
Scanner Y error
Signal cable not connected
External abort
External stop
Voltage error (15V)
Voltage error (24V)
Laser power supply error
Shutter error
Cover connector opened during marking
External sum alarm
System locked by key switch
Laser temperature
Laser power
Laser not ready for emission
Laser back reflection
Laser system error
Emergency stop button
Error
09/01/2012
Trotec Produktions- und Vertriebs GmbH_Linzer Strasse 156, A-4600 Wels, Austria, Technical Support
tel_+43 (0)7242 239-7000, fax_+43 (0)7242 239-7380, e-mail:
Below is a list of possible errors which may be detected by the system.
These will appear in the software as messages on the display.
The Reset signal (X11) or the reset button on the laser rack are used
to acknowledge an error. In order for the system to be reset, the error
or the corresponding input signal must be acknowledged.
System errors which cannot be reset or which indicate a
hardware error should only be resolved by Trotec Produktions
und Vertriebs Ges.m.b.H. trained service personnel.
Cause
Software has lost connection to the TLC2
controller
No connection to the galvo
The galvo X-axis has identified an error
The galvo Y-axis has identified an error
No connection to the marking head
External abort signal identified on X11
External stop signal identified on X11
+/- 15V power supply not functioning correctly
24V power supply not functioning correctly
Faulty laser source power supply
Shutter has not reached intended position
ICL1 and ICL2 were opened during the
marking process
External error signal identified on X11
Key switch on laser rack locked
Laser source overheated
24 V power supply outside the permissible
tolerance zone
e.g. key switch not activated
Back reflection of the laser beam
Laser power supply voltage is too high or too
low
Emergency stop button activated
+/-15V monitoring
24V laser monitoring
24V monitoring
Shutter temperature