Heatsink Installation
1. Do not apply any thermal com-
pound to the heatsink or the CPU
die; the required amount has al-
ready been applied.
2. Place the heatsink on top of the
CPU so that the four mounting
holes are aligned with those on the
retention mechanism.
3. Screw in two diagonal screws (ie
the #1 and the #2 screws) until just
snug (-do not fully tighten the
screws to avoid possible damage to
the CPU.)
4. Finish the installation by fully
tightening all four screws.
Figure 5-1. 604-pin PGA Socket: Empty and with Processor Installed
Warning!
installing the CPU. If the lever is only partly raised, damage
!
to the socket or CPU may result.
Empty socket
Lever
Triangle (pin 1)
Chapter 5: Advanced Serverboard Setup
Make sure you lift the lever completely when
Triangle locating pin 1
5-3
With processor installed