Page 2
Manual Revision 1.0b Release Date: June 6, 2008 Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document. Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 6025B-UR. Installation and maintainance should be performed by experienced technicians only. The SuperServer 6025B-UR is a high-end server based on the SC825TQ-R700U 2U rackmount chassis and the X7DBU, a dual processor serverboard that supports ®...
Page 4
UPER ERVER 6025B-UR User's Manual Chapter 5: Advanced Serverboard Setup Chapter 5 provides detailed information on the X7DBU serverboard, including the locations and functions of connections, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfi guring the serverboard.
UPER ERVER 6025B-UR User's Manual Table of Contents Chapter 1: Introduction Overview ... 1-1 Serverboard Features ... 1-2 Server Chassis Features ... 1-4 Contacting Supermicro ... 1-6 Chapter 2: Server Installation Overview ... 2-1 Unpacking the System ... 2-1 Preparing for Setup ... 2-1 Installing the System into a Rack ...
Overview The SuperServer 6025B-UR is a high-end server comprised of two main subsystems: the SC825TQ-R700U 2U server chassis and the X7DBU dual Intel Xeon processor serverboard. Please refer to our web site for information on operating systems that have been certifi ed for use with the 6025B-UR (www.supermicro.com).
UIO card types to add SAS ports, additional LAN ports, etc. to the serverboard. This allows the user to tailor the serverboard to their own needs. Note: the 6025B-UR does not come with a UIO card installed.
ATI Graphics Controller The X7DBU features an integrated ATI video controller based on the ES1000 graph- ics chip. The ES1000 was designed specifi cally for servers, featuring low power consumption, high reliability and superior longevity. Other Features Other onboard features that promote system health include onboard voltage moni- tors, a chassis intrusion header, auto-switching voltage regulators, chassis and CPU overheat sensors, virus protection and BIOS rescue.
Front Control Panel The control panel on the SuperServer 6025B-UR provides you with system monitor- ing and control. LEDs indicate system power, HDD activity, network activity, system overheat and power supply failure. A main power button and a system reset but- ton are also included.
Page 15
I/O Backplane The SC825TQ-R700U is an ATX form factor chassis designed to be used in a 2U rackmount confi guration. The I/O backplane provides seven low-profi le PCI expansion slots, one COM port, a VGA port, two USB 2.0 ports, PS/2 mouse and keyboard ports and two gigabit Ethernet ports.
Precautions in the next section. Preparing for Setup The box the SuperServer 6025B-UR was shipped in should include two sets of rail assemblies, two rail mounting brackets and the mounting screws you will need to install the system into the rack. Follow the steps in the order given to complete the installation process in a minimum amount of time.
UPER ERVER 6025B-UR User's Manual Choosing a Setup Location - Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches). - Leave approximately 30 inches of clearance in the back of the rack to allow for suffi...
Chapter 2: Server Installation Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating tempera- ture of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient tempera- ture (Tmra).
This section provides information on installing the SuperServer 6025B-UR into a rack unit. If the 6025B-UR has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly.
Installing the Server into a Telco Rack If you are installing the SuperServer 6025B-UR into a Telco type rack, follow the di- rections given on the previous pages for rack installation. The only difference in the installation procedure will be the positioning of the rack brackets to the rack.
Page 23
Chapter 2: Server Installation Figure 2-2. Installing the Server into a Rack...
UPER ERVER 6025B-UR User's Manual Checking the Serverboard Setup After you install the 6025B-UR in the rack, you will need to open the unit to make sure the serverboard is properly installed and all the connections have been made. 1. Accessing the inside of the System (see Figure 2-3) First, grasp the two handles on either side and pull the unit straight out until it locks (you will hear a "click").
Page 25
Chapter 2: Server Installation Figure 2-3. Accessing the Inside of the System...
UPER ERVER 6025B-UR User's Manual Checking the Drive Bay Setup Next, you should check to make sure the peripheral drives and the Serial ATA drives have been properly installed and all connections have been made. 1. Accessing the drive bays All drives are accessable from the front of the server.
System Interface Overview There are several LEDs on the control panel as well as others on the drive carri- ers to keep you constantly informed of the overall status of the system as well as the activity and health of specifi c components. There are also two buttons on the chassis control panel.
SUPERSERVER 6025B-UR User's Manual Control Panel LEDs The control panel located on the front of the chassis has several LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take.
HDD: Indicates IDE channel activity. On the SuperServer 6025B-UR, this LED indicates SAS/SATA and/or DVD-ROM drive activity when fl ashing. Power: Indicates power is being supplied to the system's power supply units. This LED should normally be illuminated when the system is operating.
Electrical Safety Precautions Basic electrical safety precautions should be followed to protect yourself from harm and the SuperServer 6025B-UR from damage: Be aware of the locations of the power on/off switch on the chassis as well as the room's emergency power-off switch, disconnection switch or electrical outlet.
General Safety Precautions Follow these rules to ensure general safety: Keep the area around the SuperServer 6025B-UR clean and free of clutter. The SuperServer 6025B-UR weighs approximately 57 lbs (25.9 kg.) when fully loaded. When lifting the system, two people at either end should lift slowly with their feet spread out to distribute the weight.
After accessing the inside of the system, close the system back up and secure it to the rack unit with the retention screws after ensuring that all connections have been made. ESD Precautions Electrostatic discharge (ESD) is generated by two objects with different electrical charges coming into contact with each other.
Operating Precautions Care must be taken to assure that the chassis cover is in place when the 6025B-UR is operating to assure proper cooling. Out of warranty damage to the 6025B-UR system can occur if this practice is not strictly followed.
Advanced Serverboard Setup This chapter covers the steps required to install processors and heatsinks to the X7DBU serverboard, connect the data and power cables and install add-on cards. All serverboard jumpers and connections are described and a layout and quick reference chart are included in this chapter. Remember to close the chas- sis completely when you have fi...
UPER ERVER 6025B-UR User's Manual Processor and Heatsink Installation When handling the processor, avoid placing direct pressure on the label area of the fan. Also, do not place the serverboard on a conductive surface, which can damage the BIOS battery and prevent the system from booting up.
Page 37
3. Use your thumb and your index fi nger to hold the CPU at opposite sides. 4. Align pin1 of the CPU (the cor- ner marked with a triangle) with the notched corner of the CPU socket. 5. Find the corner of the CPU that has a semi-circle cutout below a gold dot (CPU key).
Page 38
UPER ERVER 6025B-UR User's Manual Installing the Heatsink 1. Do not apply any thermal grease to the heatsink or the CPU die; the required amount has already been applied. 2. Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the (preinstalled) heatsink retention mechanism.
Connecting Cables Now that the processors are installed, the next step is to connect the cables to the serverboard. These include the data (ribbon) cables for the peripherals and control panel and the power cables. Connecting Data Cables The ribbon cables used to transfer data from the peripheral devices have been carefully routed in preconfi...
UPER ERVER 6025B-UR User's Manual Connecting the Control Panel JF1 contains header pins for various front control panel connectors. See Figure 5-1 for the pin locations of the various front control panel buttons and LED indi- cators. Please note that even and odd numbered pins are on opposite sides of each header.
I/O Ports The I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-2 below for the colors and locations of the various I/O ports. Figure 5-2. Rear Panel I/O Ports Mouse (Green) USB0/1 Ports COM1 Port (Turquoise) Keyboard...
Page 42
UPER ERVER 6025B-UR User's Manual modules of the same size and speed to be installed in pairs. You should not mix DIMMs of different sizes and speeds. Notes: Due to OS limitations, some operating systems may not show more than 4 GB of memory.
Figure 5-3. Installing DIMM into Slot To Install: Insert module vertically and press down until it snaps into place. Pay attention to the bottom notch. To Remove: Use your thumbs to gently push each release tab outward to free the DIMM from the slot.
X7DBU Quick Reference Jumper Description JBT1 CMOS Clear C1/II C Enable/Disable JPG1 VGA Enable/Disable JPL1/ JPL2 JLAN1/JLAN2 Enable/Disable Watch Dog Connector Description COM1/COM2 COM1/COM2 Serial Port Connector/Header FAN 1-8 Fan Headers 1-8 Floppy Floppy Disk Drive Connector IDE#1 IDE Hard Drive Connector Power LED (pins1-3)/Speaker Header (pins 4-7) Front Control Panel Connector Chassis Intrusion Header...
UPER ERVER 6025B-UR User's Manual Connector Defi nitions ATX Power Connector The primary ATX power supply con- nector meets the SSI (Superset ATX) 20-pin specifi cation. Make sure that the orientation of the connector is correct. See the table on the right for pin defi...
HDD LED The HDD (IDE Hard Disk Drive) LED connection is located on pins 13 and 14 of JF1. Attach the IDE hard drive LED cable to display disk activity. Refer to the table on the right for pin defi nitions. NIC1 LED The NIC1 (Network Interface Control- ler) LED connection is located on pins...
UPER ERVER 6025B-UR User's Manual Power Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1. Re- fer to the table on the right for pin defi nitions. Reset Button The Reset Button connection is lo- cated on pins 3 and 4 of JF1.
Universal Serial Bus Headers Three additional USB headers (USB2/ USB3 and USB4) are included on the serverboard. These may be used for front side access. A USB cable (not included) is needed for the connec- tion. See the table on the right for pin defi...
UPER ERVER 6025B-UR User's Manual Chassis Intrusion A Chassis Intrusion header is located at JL1. Attach the appropriate cable to inform you of a chassis intrusion. Power LED/Speaker On the JD1 header, pins 1-3 are for a power LED, pins 4-7 are for the speaker.
Wake-On-LAN The Wake-On-LAN header is desig- nated JWOL. See the table on the right for pin defi nitions. You must enable the LAN Wake-Up setting in BIOS to use this feature. You must also have a LAN card with a Wake- on-LAN connector and cable.
UPER ERVER 6025B-UR User's Manual LAN1/2 (Ethernet Ports) Two Ethernet ports (designated LAN1 and LAN2) are located beside the VGA port on the I/O backplane. These ports accept RJ45 type cables. Alarm Reset (JAR) The system will notify you in the event of a power supply failure.
Jumper Settings Explanation of Jumpers To modi f y the operat ion of the serverboard, jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function of the connector. Pin 1 is identifi ed with a square solder pad on the printed circuit board.
UPER ERVER 6025B-UR User's Manual LAN Enable/Disable Change the setting of jumper JPL1 or JPL2 to enable or disable the onboard Ethernet (RJ45) ports LAN1 and LAN2, respectively. See the table on the right for jumper settings. The default setting...
5-10 Onboard Indicators LAN1/LAN2 LEDs The Ethernet ports (located beside the VGA port) have two LEDs. On each Gigabit LAN port, one LED indicates activity when blinking while the other LED may be green, amber or off to indicate the speed of the connection. See the table on the right for the func- tions associated with the connection speed LED.
UPER ERVER 6025B-UR User's Manual 5-11 Floppy, IDE and SATA Drive Connections Note the following when connecting the fl oppy and hard disk drive cables: • The fl oppy disk drive cable has seven twisted wires. • A red mark on a wire typically designates the location of pin 1.
IDE Connector There are no jumpers to con- fi gure the onboard IDE#1 con- nector. See the table on the right for pin defi nitions. SATA Ports See the table on the right for pin defi nitions for the onboard SATA ports.
Advanced Chassis Setup This chapter covers the steps required to install components and perform main- tenance on the SC825TQ-R700U chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the step that follows. Tools Required The only tool you will need to install components and perform maintenance is a Philips screwdriver.
UPER ERVER 6025B-UR User's Manual Figure 6-1. Front and Rear Chassis Views 3.5" Drive Bays (2) Slim DVD-ROM Drive Hard Drives (8) Keyboard/Mouse Ports USB Ports COM1 Port Control Panel The control panel (located on the front of the chassis) must be connected to the JF1 connector on the serverboard to provide you with system status indications.
Chapter 6: Advanced Chassis Setup System Fans Three 8-cm hot-swap fans provide the cooling for the SuperServer 6025B-UR. It is very important that the chassis top cover is properly installed and making a good seal in order for the cooling air to circulate properly through the chassis and cool the components.
UPER ERVER 6025B-UR User's Manual Figure 6-2. Removing System Cooling Fans Drive Bay Installation/Removal Accessing the Drive Bays SAS/SATA Drives: You do not need to access the inside of the chassis or remove power to replace or swap SAS/SATA drives. Proceed to the next step for instruc- tions.
SAS/SATA Drive Installation 1. Mounting a SAS/SATA drive in a drive carrier The SAS/SATA drives are mounted in drive carriers to simplify their installation and removal from the chassis. These carriers also help promote proper airfl ow for the drives. For this reason, even empty carriers without SAS/SATA drives installed must remain in the chassis.
Page 64
UPER ERVER 6025B-UR User's Manual 2. Installing/removing hot-swap SAS/SATA drives The SAS/SATA drive carriers are all easily accessible at the front of the chassis. These hard drives are hot-pluggable, meaning they can be removed and installed without powering down the system. To remove a carrier, push the release button located beside the drive LEDs.
The top cover of the chassis must be opened to gain full access to the DVD-ROM and fl oppy drive bays. The 6025B-UR accomodates only slim type DVD-ROM drives. Side mounting brakets are typically needed to mount a slim DVD-ROM drive in the 6025B-UR server.
ERVER 6025B-UR User's Manual Power Supply The SuperServer 6025B-UR has a 700 watt redundant power supply consisting of two power modules. Each power supply module has an auto-switching capability, which enables it to automatically sense and operate at a 100V - 240V input volt- age.
Introduction This chapter describes the Phoenix BIOS™ Setup utility for the X7DBU. The Phoenix ROM BIOS is stored in a fl ash chip and can be easily upgraded using a fl oppy disk-based program. Note: Due to periodic changes to the BIOS, some settings may have been added or deleted and might not yet be recorded in this manual.
UPER ERVER 6025B-UR User's Manual Running Setup Default settings are in bold text unless otherwise noted. The BIOS setup options described in this section are selected by choosing the ap- propriate text from the main BIOS Setup screen. All displayed text is described in this section, although the screen display is often all you need to understand how to set the options (See the next page).
Chapter 7: BIOS Main BIOS Setup Menu Main Setup Features System Time To set the system date and time, key in the correct information in the appropriate fi elds. Then press the <Enter> key to save the data. System Date Using the arrow keys, highlight the month, day and year fi...
Page 70
UPER ERVER 6025B-UR User's Manual IDE Channel 0 Master/Slave and Secondary IDE Master/Slave These settings allow the user to set the parameters of IDE Channel 0 Master/Slave and Secondary IDE Master/Slave slots. Press <Enter> to activate the following submenu screen for detailed options of these items. Set the correct confi gurations accordingly.
Page 71
Chapter 7: BIOS Multi-Sector Transfers This item allows the user to specify the number of sectors per block to be used in multi-sector transfer. The options are Disabled, 4 Sectors, 8 Sectors, and 16 Sectors. LBA Mode Control This item determines whether the Phoenix BIOS will access the IDE Channel 0 Master Device via the LBA mode.
Page 72
UPER ERVER 6025B-UR User's Manual Parallel ATA This setting allows the user to enable or disable the function of Parallel ATA. The options are Enabled and Disabled. Serial ATA This setting allows the user to enable or disable the function of Serial ATA. The options are Disabled and Enabled.
Advanced Setup Choose Advanced from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. The items with a triangle beside them have submenus that can be accessed by highlighting the item and pressing <Enter>. Boot Features Access the submenu to make changes to the following settings.
Page 74
UPER ERVER 6025B-UR User's Manual Power Button Behavior If set to Instant-Off, the system will power off immediately as soon as the user hits the power button. If set to 4-sec., the system will power off when the user presses the power button for 4 seconds or longer. The options are instant-off and 4-sec override.
Page 75
Chapter 7: BIOS Select Write Protect to prevent data from being written into the base memory area of Block 0-512K. Select Write Back to allow CPU to write data back directly from the buffer without writing data to the System Memory for fast CPU data processing and operation.
Page 76
UPER ERVER 6025B-UR User's Manual Emulated IRQ Solutions When Enabled, Emulated IRQ Scheme allows PCI devices to run on legacy operating systems that use the MSI mechanism to generate INTX compatible interrupts. The options are Disabled and Enabled. PCI-Exp. I/O Performance Some add-on cards perform faster with the coalesce feature, which limits the payload size to 128 Bytes;...
Page 77
Enable Master This setting allows you to enable the selected device as the PCI bus master. The options are Enabled and Disabled. Latency Timer This setting allows you to set the clock rate for Bus Master. A high-priority, high- throughout device may benefi t from a greater clock rate. The options are Default, 0020h, 0040h, 0060h, 0080h, 00A0h, 00C0h, and 00E0h.
Page 78
UPER ERVER 6025B-UR User's Manual Branch 1 Rank Interleaving & Sparing Select enable to enable the functions of Memory Interleaving and Memory Sparing for Branch 1 Rank. The options for Memory Interleaving are 1:1, 2:1 and 4:1. The options for Sparing are Enabled and Disabled.
Page 79
Chapter 7: BIOS Enabling Multi-Media Timer Select Yes to activate a set of timers that are alternative to the traditional 8254 timers for the OS use. The options are Yes and No. USB Function Select Enabled to enable the function of USB devices specifi ed. The settings are Enabled and Disabled.
Page 80
UPER ERVER 6025B-UR User's Manual Adjacent Cache Line Prefetch The CPU fetches the cache line for 64 bytes if this option is set to Disabled. The CPU fetches both cache lines for 128 bytes as comprised if Enabled. The default settings are Disabled for the Intel 5100 Series Processors and Enable for the 5000 Series Processors.
Page 81
Interrupt This setting allows you to select the IRQ (interrupt request) for serial port A. The options are IRQ3 and IRQ4. Serial Port B This setting allows you to assign control of serial port B. The options are Enabled (user defi ned), Disabled, Auto (BIOS controlled) and OS Controlled. Mode This setting allows you to set the type of device that will be connected to serial port B.
Page 82
UPER ERVER 6025B-UR User's Manual DMI Event Logging Access the submenu to make changes to the following settings. Event Log Validity This is a display to inform you of the event log validity. It is not a setting. Event Log Capacity This is a display to inform you of the event log capacity.
Page 83
Chapter 7: BIOS Console Redirection Access the submenu to make changes to the following settings. COM Port Address This item allows you to specify which COM port to direct the remote console to: Onboard COM A or Onboard COM B. This setting can also be Disabled. BAUD Rate This item allows you to set the BAUD rate for console redirection.
UPER ERVER 6025B-UR User's Manual Hardware Monitor Logic Note: The Phoenix BIOS will automatically detect the type of CPU(s) and hardware monitoring chip used on the motherboard and will display the Hardware Monitoring Screen accordingly. Your Hardware Monitoring Screen may look like the one shown on this page, or on p.
Page 85
Chapter 7: BIOS Hardware Monitor Logic (See note on page 7-18.) CPU Temperature Threshold This option allows the user to set a CPU temperature threshold that will activate the alarm system when the CPU temperature reaches this pre-set temperature threshold. The hardcode default setting is 75 CPU1 Temperature/CPU1 Second Core CPU2 Temperature/CPU2 Second Core Temperature Monitoring (Available if supported by the CPU)
Page 86
UPER ERVER 6025B-UR User's Manual IPMI (Available only when an IPMI card is installed in the system.) IPMI Specifi cation Version: Firmware Version: This item displays the current Firmware Version. System Event Logging Select Enabled to enable IPMI Event Logging. When this function is set to Disabled, the system will continue to log events received via system interface.
Page 87
Chapter 7: BIOS OS Boot Watch Dog Set to Enabled to enable OS Boot Watch Dog. The options are Enabled and Disabled. Timer for Loading OS (Minutes) This feature allows the user to set the time value (in minutes) for the previous item: OS Boot Watch Dog by keying-in a desired number in the blank.
Page 88
UPER ERVER 6025B-UR User's Manual Realtime Sensor Data This feature display information from motherboard sensors, such as temperatures, fan speeds and voltages of various components. 7-22...
Chapter 7: BIOS Security Choose Security from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. Security setting options are displayed by highlighting the setting using the arrow keys and pressing <Enter>. All Security BIOS settings are described in this section.
UPER ERVER 6025B-UR User's Manual Password on Boot This setting allows you to determine if a password is required for a user to enter the system at system boot. The options are Enabled (password required) and Disabled (password not required).
Chapter 7: BIOS Exit Choose Exit from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. All Exit BIOS settings are described in this section. Exit Saving Changes Highlight this item and hit <Enter> to save any changes you've made and to exit the BIOS Setup utility.
Appendix A: BIOS POST Messages Appendix A BIOS POST Messages During the Power-On Self-Test (POST), the BIOS will check for problems. If a prob- lem is found, the BIOS will activate an alarm or display a message. The following is a list of such BIOS messages.
Page 94
UPER ERVER 6025B-UR User's Manual System CMOS checksum bad - Default confi guration used System CMOS has been corrupted or modifi ed incorrectly, perhaps by an application program that changes data stored in CMOS. The BIOS installed Default Setup Values.
Page 95
Appendix A: BIOS POST Messages System cache error - Cache disabled RAM cache failed and BIOS disabled the cache. On older boards, check the cache jumpers. You may have to replace the cache. See your dealer. A disabled cache slows system performance considerably.
Page 96
UPER ERVER 6025B-UR User's Manual Fixed Disk n Fixed disk n (0-3) identifi ed. Invalid System Confi guration Data Problem with NVRAM (CMOS) data. I/O device IRQ confl ict I/O device IRQ confl ict error. PS/2 Mouse Boot Summary Screen: PS/2 Mouse installed.
Page 97
Appendix A: BIOS POST Messages Press <F1> to resume, <F2> to Setup, <F3> for previous Displayed after any recoverable error message. Press <F1> to start the boot process or <F2> to enter Setup and change the settings. Press <F3> to display the previous screen (usually an initialization error of an Option ROM, i.e., an add-on card).
Appendix B BIOS POST Codes This section lists the POST (Power On Self Test) codes for the PhoenixBIOS. POST codes are divided into two categories: recoverable and terminal. Recoverable POST Errors When a recoverable type of error occurs during POST, the BIOS will display an POST code that describes the problem.
Page 100
UPER ERVER 6025B-UR User's Manual POST Code Description 8254 timer initialization 8237 DMA controller initialization Reset Programmable Interrupt Controller 1-3-1-1 Test DRAM refresh 1-3-1-3 Test 8742 Keyboard Controller Set ES segment register to 4 GB Auto size DRAM Initialize POST Memory Manager...
Page 101
POST Code Description Test RAM between 512 and 640 kB Test extended memory Test extended memory address lines Jump to UserPatch1 Confi gure advanced cache registers Initialize Multi Processor APIC Enable external and CPU caches Setup System Management Mode (SMM) area Display external L2 cache size Load custom defaults (optional) Display shadow-area message...
Page 102
UPER ERVER 6025B-UR User's Manual POST Code Description Check for SMART Drive (optional) Set up Power Management Initialize security engine (optional) Enable hardware interrupts Determine number of ATA and SCSI drives Set time of day Check key lock Initialize typematic rate Erase <ESC>...
Page 103
POST Code Description Unknown interrupt Check Intel Branding string Alert Standard Format initialization Late init for IPMI Log error if micro-code not updated properly The following are for boot block in Flash ROM POST Code Description Initialize the chipset Initialize the bridge Initialize the CPU Initialize system timer Initialize system I/O...
Appendix C: Software Installation Appendix C Software Installation After all the hardware has been installed, you must fi rst confi gure Intel's ESB2 SATA RAID before you install the Windows Operating System and other software drivers. Important Notes: If you do not wish to confi gure onboard SATA RAID functions, please go directly to Section C-3.
Page 106
UPER ERVER 6025B-UR User's Manual RAID Confi gurations The following types of RAID confi gurations are supported: RAID 0 (Data Striping): this writes data in parallel, interleaved ("striped") sections of two hard drives. Data transfer rate is doubled over using a single disk.
Page 107
Appendix C: Software Installation Using the Intel ESB2 SATA RAID Utility Program 1. Creating, Deleting and Resetting RAID Volumes a. After the system exits from the BIOS Setup Utility, it will automatically reboot. The following screen appears after the Power-On Self Test. b.
Page 108
UPER ERVER 6025B-UR User's Manual Creating a RAID 0 Volume a. Select "Create RAID Volume" from the main menu and press the <Enter> key. The following screen will appear: b. Specify a name for the RAID 0 set and press the <Tab> key or the <Enter> key to go to the next fi...
Page 109
Appendix C: Software Installation Creating a RAID 1 Volume a. Select "Create RAID Volume" from the main menu and press the <Enter> key. The following screen will appear: b. Specify a name for the RAID 1 set and press the <Tab> key or the <Enter> key to go to the next fi...
Page 110
UPER ERVER 6025B-UR User's Manual Creating a RAID 10 (RAID 1+ RAID 0) a. Select "Create RAID Volume" from the main menu and press the <Enter> key. The following screen will appear: b. Specify a name for the RAID 10 set and press <Enter>.
Page 111
Appendix C: Software Installation Creating a RAID 5 Set (Parity) a. Select "Create RAID Volume" from the main menu and press the <Enter> key. The following screen will appear: b. Specify a name for the RAID 5 set and press <Enter>. c.
Page 112
UPER ERVER 6025B-UR User's Manual Deleting a RAID Volume Warning! Be sure to back up your data before deleting a RAID set. You will lose all data on the disk drives when deleting a RAID set. a. From the main menu, select item2-Delete RAID Volume, and press <Enter>.
Page 113
Resetting to Non-RAID and Resetting a RAID HDD Warning! Use cautious when resetting a RAID volume HDD to non- RAID or resetting a RAID HDD. Resetting a RAID volume HDD or resetting a RAID HDD will reformat the HDD and delete the internal RAID structure on the drive.
Page 114
UPER ERVER 6025B-UR User's Manual C-2 Installing Windows XP/2000/2003 for RAID Systems New Operating System-Windows XP/2000/2003 Installation a. Insert the Microsoft Windows XP/2000/2003 Setup CD in the CD Drive and the system will start booting up from CD. b. Press the <F6> key when the message" Press F6 if you need to install a third party SCSI or RAID driver"...
Appendix C: Software Installation C-3 Installing the Operating System and other Software Programs After the hardware has been installed, you must fi rst install the operating system, and then, other software drivers. The necessary drivers are all included on the Supermicro CDs that came packaged with your motherboard.
Page 116
UPER ERVER 6025B-UR User's Manual Supero Doctor III The Supero Doctor III program is a Web base management tool that supports remote management capability. It includes Remote and Local Management tools. The local management is called SD III Client. The Supero Doctor III program included on the CDROM that came with your motherboard allows you to moni- tor the environment and operations of your system.
Page 117
Appendix C: Software Installation Supero Doctor III Interface Display Screen-II (Remote Control) Note: SD III Software Revision 1.0 can be downloaded from our Web Site at: ftp:// ftp.supermicro.com/utility/Supero_Doctor_III/. You can also download SDIII User's Guide at: http://www.supermicro.com/PRODUCT/Manuals/SDIII/UserGuide.pdf. For Linux, we will still recommend Supero Doctor II. C-13...
Appendix D: System Specifi cations Appendix D System Specifi cations Processors Single or dual Intel® Xeon™ 5300/5100/5000 Sequence processors at a front side (system) bus speed of 1333/1066/667 MHz. Note: Please refer to our web site for a complete listing of supported processors. Chipset Intel 5000P/ESB2 chipset BIOS...
Page 120
UPER ERVER 6025B-UR User's Manual Serverboard X7DBU (proprietary form factor) Dimensions: 12 x 13.05 in (305 x 331 mm) Chassis 6025B-UR: SC825TQ-R700U, 2U rackmount Dimensions (both): (WxHxD) 16.8 x 3.5 x 25.5 in. (427 x 89 x 648 mm) Weight Gross (Bare Bone): 57 lbs.
Page 121
Appendix D: System Specifi cations Regulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) Safety: EN 60950/IEC 60950-Compliant, UL Listed (USA), CUL Listed (Canada), TUV Certifi...
Need help?
Do you have a question about the SuperServer 6025B-UR and is the answer not in the manual?
Questions and answers