  • Page 1 UPER ERVER ® 6038R-TXR USER’S MANUAL 1.0a...
  • Page 2 This product, including software and This manual is written for professional system integrators and PC technicians. It documentation, is the property of Supermicro and/or its licensors, and is supplied only under a provides information for the installation and use of the SuperServer 6038R-TXR license.
  • Page 3 Preface UPER ERVER 6038R-TXR User's Manual Notes Chapter 6: Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC835XTQ-R982B server chassis. You should follow the procedures given in this chapter when installing, removing or reconfiguring SATA or peripheral drives and when replacing system power supply units and cooling fans.
  • Page 4: Table Of Contents

    Power Disconnection Warning ................ 4-6 Front Control Panel ..................1-3 Equipment Installation ..................4-8 Cooling System ....................1-3 Restricted Area ....................4-9 Contacting Supermicro ..................1-5 Battery Handling .................... 4-10 Chapter 2 Server Installation Redundant Power Supplies ................4-12 Overview ......................2-1 Backplane Voltage ..................
  • Page 5 UPER ERVER 6038R-TXR User's Manual X10DRX Quick Reference ................5-13 Connector Definitions ................... 5-15 Jumper Settings .................... 5-21 5-10 Onboard Indicators ..................5-23 5-11 SATA Ports ....................5-24 5-12 Installing Software ..................5-25 SuperDoctor® 5 .................... 5-26 5-13 Onboard Battery .................... 5-27 Chapter 6 Advanced Chassis Setup Static-Sensitive Devices ..................
  • Page 6: Chapter 1 Introduction

    Chapter 1 Introduction Overview The SuperServer 6038R-TXR is comprised of two main subsystems: the SC835XTQ-R982B 3U server chassis and the X10DRX dual Intel Xeon processor serverboard. Please refer to our website for information on operating systems that have been certified for use with the system (www.supermicro.com).
  • Page 7: Serverboard Features

    IPMI IPMI (Intelligent Platform Management Interface) is a hardware-level interface At the heart of the SuperServer 6038R-TXR lies the X10DRX, a dual processor specification that provides remote access, monitoring and administration for serverboard based on the Intel C612 chipset. Below are the main features of the Supermicro server platforms.
  • Page 8: Contacting Supermicro

    Fax: +1 (408) 503-8008 VR12.5 PCIE-3.0 x8 * 5 PCIE-2.0 x4 * 1 6 PHASE PCIE2.0 x8 Slots 11(x4) 145W Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) PCIE3.0 x8 Slots [6/7/8/9/10] Website: www.supermicro.com CPU REAR PROCESSOR 2 Europe Address: Super Micro Computer B.V.
  • Page 9 UPER ERVER 6038R-TXR User's Manual Notes...
  • Page 10: Chapter 2 Server Installation

    Precautions in the next section. Preparing for Setup The box the SuperServer 6038R-TXR was shipped in should include two sets of rail assemblies, two rail mounting brackets and the mounting screws you will need to install the system into the rack. Follow the steps in the order given to complete the installation process in a minimum amount of time.
  • Page 11: Warnings And Precautions

    Chapter 2: Server Installation UPER ERVER 6038R-TXR User's Manual • Rack Mounting Considerations This product is not suitable for use with visual display work place devices acccording to §2 of the the German Ordinance for Work with Visual Display Units. Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating tempera- ture of the rack environment may be greater than the ambient temperature of the...
  • Page 12: Installing The System Into A Rack

    Chapter 2: Server Installation UPER ERVER 6038R-TXR User's Manual Installing the System into a Rack This section provides information on installing the SC835 chassis into a rack unit with the quick-release rails provided. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly.
  • Page 13: Installing The Chassis Into A Rack

    UPER ERVER 6038R-TXR User's Manual Figure 2-4. Installing the Chassis into the Rack Installing the Chassis into a Rack Installing into a Rack 1. Confirm that the inner and outer rails are installed on the rack. 2. Line chassis rails with the front of the rack rails. 3.
  • Page 14: Chapter 3 System Interface

    Chapter 3: System Interface Chapter 3 System Interface Overview There are several LEDs on the control panel as well as others on the drive carri- ers to keep you constantly informed of the overall status of the system as well as the activity and health of specific components.
  • Page 15: Control Panel Leds

    LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective On the SuperServer 6038R-TXR, this LED indicates SATA hard drive and/or DVD- action you may need to take.
  • Page 16 SUPERSERVER 6038R-TXR User's Manual Notes...
  • Page 17: Chapter 4 Standardized Warning Statements For Ac Systems

    Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. These warnings may also be found on our web site at http://www.supermicro.com/ about/policies/safety_information.cfm. Warning Definition Warning! This warning symbol means danger.
  • Page 18 SUPERSERVER 6038R-TXR User's Manual Warning Statements for AC Systems ‫جسذٌة‬ ‫اصابة‬ ً‫تتسبب ف‬ ‫حالة ٌوكي أى‬ ً‫اًك ف‬ ‫خطز‬ ًٌ‫ٌع‬ ‫هذا الزهز‬ !‫تحذٌز‬ Warnung ‫الذوائز‬ ‫بالوخاطز الٌاجوة عي‬ ‫ي على علن‬ ، ‫ك‬ ‫هعذات‬ ‫تعول على أي‬ ‫قبل أى‬ ‫الكهزبائٍة‬...
  • Page 19: Installation Instructions

    SUPERSERVER 6038R-TXR User's Manual Chapter 4: Warning Statements for AC Systems Installation Instructions Circuit Breaker Warning! Warning! Read the installation instructions before connecting the system to the power source. This product relies on the building's installation for short-circuit (overcurrent) 設置手順書...
  • Page 20: Power Disconnection Warning

    SUPERSERVER 6038R-TXR User's Manual Chapter 4: Warning Statements for AC Systems Warnung Das System muss von allen Quellen der Energie und vom Netzanschlusskabel ‫في‬ ‫التي تم تثبيتها‬ ‫مه الدوائرالقصيرة‬ ‫الحمايت‬ ‫معداث‬ ‫يعتمد على‬ ‫هذا المنتج‬ getrennt sein, das von den Spg.Versorgungsteilmodulen entfernt wird, bevor es ‫المبنى‬...
  • Page 21: Equipment Installation

    SUPERSERVER 6038R-TXR User's Manual Chapter 4: Warning Statements for AC Systems Equipment Installation Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door geschoold en gekwalificeerd personeel. Warning! Only trained and qualified personnel should be allowed to install, replace, or service Restricted Area this equipment.
  • Page 22: Battery Handling

    SUPERSERVER 6038R-TXR User's Manual Chapter 4: Warning Statements for AC Systems Warnung ‫אזור עם גישה מוגבלת‬ Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die !‫אזהרה‬ Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. ‫יש להתקין את היחידה באזורים שיש בהם הגבלת גישה. הגישה ניתנת בעזרת‬...
  • Page 23: Redundant Power Supplies

    SUPERSERVER 6038R-TXR User's Manual Chapter 4: Warning Statements for AC Systems Redundant Power Supplies ‫امداد الطاقة‬ ‫بوحدات‬ ‫عدة اتصاالت‬ ‫جهاز‬ ‫ال‬ ‫يكون لهذا‬ ‫قد‬ ‫الكهرباء‬ ‫عن‬ ‫وحدة‬ ‫ال‬ ‫لعسل‬ ‫كافة االتصاالت‬ ‫يجب إزالة‬ Warning! This unit might have more than one power supply connection. All connections must 경고!
  • Page 24: Comply With Local And National Electrical Codes

    SUPERSERVER 6038R-TXR User's Manual Chapter 4: Warning Statements for AC Systems Attention ¡Advertencia! Lorsque le système est en fonctionnement, des tensions électriques circulent sur La instalacion del equipo debe cumplir con las normas de electricidad locales y le fond de panier. Prendre des précautions lors de la maintenance.
  • Page 25: Hot Swap Fan Warning

    SUPERSERVER 6038R-TXR User's Manual Chapter 4: Warning Statements for AC Systems 当您从机架移除风扇装置,风扇可能仍在转动。小心不要将手指、螺丝起子和其他 Warnung 物品太靠近风扇 Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen. 警告 ¡Advertencia! 當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他 物品太靠近風扇。 Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales.
  • Page 26: Power Cable And Ac Adapter

    UL ou CSA câbles certifiés qui ont UL ou CSA indiqué sur le code use of UL or CSA -certified cables (that have UL/CSA shown on the code) for any pour tous les autres appareils électriques que les produits désignés par Supermicro other electrical devices than products designated by Supermicro only.
  • Page 27 Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik van UL of CSA gecertificeerde kabels die UL of CSA die op de code voor andere elektrische apparaten dan de producten die door Supermicro alleen. 4-20...
  • Page 28: Chapter 5 Advanced Serverboard Setup

    Chapter 5: Advanced Serverboard Setup Chapter 5 Advanced Serverboard Setup This chapter covers the data and power cables and expansion cards. All serverboard jumpers and connections are also described. A layout and quick reference chart are included in this chapter for your reference. Remember to completely close the chassis when you have finished working with the serverboard to better cool and protect the system.
  • Page 29: Connecting Cables

    Chapter 5: Advanced Serverboard Setup UPER ERVER 6038R-TXR User's Manual Connecting Cables Figure 5-1. Control Panel Header Pins Several cables need to be connected from the chassis to the serverboard. These Ground include the data cables for the peripherals and control panel and the power cables. Connecting Data Cables FP PWRLED 3.3 V...
  • Page 30: Installing The Processor And Heatsink

    (Do not drop the CPU • on the socket. Do not move the Refer to the Supermicro web site for updates on CPU support. CPU horizontally or vertically and do not rub the CPU against any Installing an LGA 2011 Processor pins of the socket, which may damage the CPU or the socket.)
  • Page 31: Installing A Cpu Heatsink

    Chapter 5: Advanced Serverboard Setup UPER ERVER 6038R-TXR User's Manual Warning: You can only install the CPU to the socket in one direction. Make sure that Installing a CPU Heatsink the CPU is properly inserted into the socket before closing the load plate. If it doesn't Note: heatsinks are optional parts.
  • Page 32: Removing The Heatsink

    Chapter 5: Advanced Serverboard Setup UPER ERVER 6038R-TXR User's Manual Installing Memory Removing the Heatsink Warning: We do not recommend that the CPU or the heatsink be removed. However, if you do need to uninstall the heatsink, please follow the instructions below to uninstall Warning: Exercise extreme care when installing or removing DIMM modules to prevent the heatsink to prevent damage done to the CPU or the CPU socket.
  • Page 33: Memory Support

    Adding PCI Add-On Cards 1 CPU & P1-DIMMA1/P1-DIMMB1, P1-DIMMC1/P1-DIMMD1 + Any memory pairs in P1- 5~8 DIMMs DIMMA2/P1-DIMMB2/P1-DIMMC2/P1-DIMMD2 slots The SuperServer 6038R-TXR server can support 10 PCI-Express 3.0 x8 and one 2 CPUs & CPU1 + CPU2 4 DIMMs P1-DIMMA1/P1-DIMMB1, P2-DIMME1/P2-DIMMF1 PCI-Express 2.0 x4 (in x8 slot) expansion cards.
  • Page 34: Serverboard Details

    Chapter 5: Advanced Serverboard Setup UPER ERVER 6038R-TXR User's Manual Serverboard Details 6. Push the PCI bracket release tab down until it locks into place with an audible "click". Figure 5-8. X10DRX Layout (not drawn to scale) 7. Secure the PCI card with the screw previously removed from the chassis. IPMI LAN 8.
  • Page 35: Connector Definitions

    Chapter 5: Advanced Serverboard Setup UPER ERVER 6038R-TXR User's Manual Connector Definitions Connector Description COM1/COM2 COM1 Port/COM2 Header Power Connections Fan1-7, A-D CPU/System Fan Headers (FAN6: CPU1 fan, FAN7: CPU2 fan) 24-pin Main Power Connector Pin Definitions Control Panel Header A 2 4 - p i n m a i n p o w e r s u p p l y Pin# Definition Pin # Definition...
  • Page 36 Chapter 5: Advanced Serverboard Setup UPER ERVER 6038R-TXR User's Manual NIC1/NIC2 LED Indicators Power Button GLAN1/2 LED Pin Definitions (JF1) The NIC (Network Interface Controller) The Power Button connection is located Pin# Definition LED connection for GLAN port 1 is on pins 1 and 2 of JF1.
  • Page 37 IPMI on the serverboard. For more Data JIPMB1. Connect the appropriate information on IPMI, please refer to Ground cable here to use the IPMB I the IPMI User's Guide posted on our Clock connection on your system. website at http://www.supermicro.com. No Connection 5-18 5-19...
  • Page 38: Jumper Settings

    Ground backward-compatible power support Ground to non-Supermicro SATA DOMs that require external power. CMOS Clear JBT1 is used to clear CMOS (which will also clear any passwords). Instead of pins, this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS.
  • Page 39: 5-10 Onboard Indicators

    Chapter 5: Advanced Serverboard Setup UPER ERVER 6038R-TXR User's Manual LAN1/2 Enable/Disable ME Manufacturing Mode Select LAN1/2 Enable/Disable Change the setting of jumper JPL1 Close pin 2 and pin 3 of Jumper Jumper Settings to enable or disable the LAN1/LAN2 JPME2 to bypass SPI flash security Jumper Setting Definition ME Mode Select...
  • Page 40: 5-11 Sata Ports

    UPER ERVER 6038R-TXR User's Manual 5-11 SATA Ports 5-12 Installing Software The Supermicro FTP site contains drivers and utilities for your system at ftp://ftp. supermicro.com. Some of these must be installed, such as the chipset driver. SATA 3.0 Ports After accessing the FTP site, go into the CDR_Images directory and locate the ISO Ten SATA 3.0 ports (I-SATA0-5, S-SATA0-3) are provided on the X10DRX.
  • Page 41: Superdoctor® 5

    5-13 Onboard Battery SuperDoctor® 5 The Supermicro SuperDoctor 5 is a program that functions in a command-line Please handle used batteries carefully. Do not damage the battery in any way; a or web-based interface in Windows and Linux operating systems. The program damaged battery may release hazardous materials into the environment.
  • Page 42 UPER ERVER 6038R-TXR User's Manual Notes 5-28...
  • Page 43: Chapter 6 Advanced Chassis Setup

    Chapter 6: Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform main- tenance on the SC835XTQ-R982B chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the step that follows.
  • Page 44: Control Panel

    Chapter 6: Advanced Chassis Setup UPER ERVER 6038R-TXR User's Manual Accessing the Inside of the System Figure 6-1. Front and Rear Chassis Views Performing maintenance on componenets such as fans requires access to the inside of the server system. Follow the steps below to remove the top/left side cover to Slim DVD-ROM Drive (optional) Control Panel gain access to the inside of the 6038R-TXR.
  • Page 45: System Fans

    System power does not need to be removed since the fans are hot-pluggable. Replace the failed fan with an identical 8-cm 12 volt fan (available from Supermicro). 1. Open the chassis and locate the faulty fan. Never run the server for an ex- tended period of time with the chassis open.
  • Page 46: Air Shroud

    Installation" section later in this chapter for instructions. Hard Drive Backplane Warning: Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro The hard drives plug into a backplane that provides power, drive ID and bus termi- website at http://www.supermicro.com/products/nfo/files/storage/SAS-1-Com-...
  • Page 47: Dvd-Rom Drive Installation

    Chapter 6: Advanced Chassis Setup UPER ERVER 6038R-TXR User's Manual DVD-ROM Drive Installation The SC835 chassis model supports a slim DVD-ROM drive. Use these instructions in this section in the event that you must replace any of these components. Figure 6-5. Installing a Hard Drive to a Carrier Installing a DVD-ROM Drive (Figure 6-6) 1.
  • Page 48: Power Supply

    ERVER 6038R-TXR User's Manual Power Supply The SuperServer 6038R-TXR has a 980 watt redundant power supply consisting of two power modules. Each power supply module has an auto-switching capability, which enables it to automatically sense and operate at a 100V - 240V input voltage.
  • Page 49: Chapter 7 Bios

    The configuration data that determines the system parameters may be changed by entering the AMI BIOS setup utility by pressing <F2> at the appropriate time during system boot. Note: For AMI UEFI BIOS Recovery, please refer to the UEFI BIOS Recovery User Guide posted at http://www.supermicro.com/support/manuals/.
  • Page 50: Main Setup

    ERVER 6038R-TXR User's Manual Chapter 7: BIOS Starting the Setup Utility Supermicro X10DRX Normally, the only visible Power-On Self-Test (POST) routine is the memory test. BIOS Version As the memory is being tested, press the <F2> key to enter the main menu of This item displays the version of the BIOS ROM used in this system.
  • Page 51: Boot Features

    UPER ERVER 6038R-TXR User's Manual Chapter 7: BIOS Boot Features Power Button Function If this feature is set to Instant_Off, the system will power off immediately as soon Quiet Boot as the user presses the power button. If this feature is set to 4-Second Override, Use this item to select the bootup screen display between POST messages and the system will power off when the user presses the power button for 4 seconds or the OEM logo.
  • Page 52: Advanced Power Management Configuration

    UPER ERVER 6038R-TXR User's Manual Chapter 7: BIOS If this feature is set to Enable, the DCU (Data Cache Unit) IP prefetcher will prefetch Clock Spread Spectrum the IP address in advance to improve network connectivity and system performance. Select Enable to enable Clock Spectrum support, which will allow the BIOS attempt The options are Disable and Enable.
  • Page 53: Chipset Configuration

    UPER ERVER 6038R-TXR User's Manual Chapter 7: BIOS CPU C6 Report ing fan-speeds, which might compromise system performance. The fan speeds are controlled by the firmware management via IPMI 2.0. The options are Performance, Select Enable to allow the BIOS to report the CPU C6 State (ACPI C3) to the Balanced Performance, Balanced Power, and Power.
  • Page 54 UPER ERVER 6038R-TXR User's Manual Chapter 7: BIOS IOU0 (IIO1 PCIe Port 2) This item configures the link speed of a PCI-E port specified by the user. The options are Gen 1 (Generation 1) (2.5 GT/s), Gen 2 (Generation 2) (5 GT/s), This item configures the PCI-E port Bifuraction setting for a PCI-E port specified and Gen 3 (Generation 3) (8 GT/s).
  • Page 55: Memory Configuration

    UPER ERVER 6038R-TXR User's Manual Chapter 7: BIOS No Snoop Link Frequency Select Select Enable to support no-snoop mode for each CB device. The options are Use this feature to select the desired QPI link frequency. The options are 6.4 Disable and Enable.
  • Page 56: Dimm Information

    UPER ERVER 6038R-TXR User's Manual Chapter 7: BIOS Select Enable to enable memory-sparing support for memory ranks to improve Enable ADR memory performance. The options are Disabled and Enabled. Asynchronous DRAM Refresh (ADR), supported by the Haswell-EP/EN pro- cessors, provides a mechanism to preserve the key data in DDR4 NVDIMM Patrol Scrub system memory when an AC power-supply failure occurs.
  • Page 57 UPER ERVER 6038R-TXR User's Manual Chapter 7: BIOS EHCI Hand-Off *If the item above "Configure SATA as" is set to AHCI, the following items will display: This item is for operating systems that do not support Enhanced Host Controller Support Aggressive Link Power Management Interface (EHCI) hand-off.
  • Page 58: Sata Ports

    UPER ERVER 6038R-TXR User's Manual Chapter 7: BIOS Port 0 ~ Port 5 SATA Device Type (Available when a SATA port is Port 0 ~ Port 5 Spin Up Device detected) On an edge detect from 0 to 1, set this item to allow the PCH to start a COMRE- Use this item to specify if the SATA port specified by the user should be con- SET initialization to the device.
  • Page 59 UPER ERVER 6038R-TXR User's Manual Chapter 7: BIOS sSATA Port 0~ Port 3 SATA/sSATA RAID Boot Select Select Enabled to enable an sSATA port specified by the user. The options are Select SATA Controller to boot the system from a SATA RAID device. Select Disabled and Enabled.
  • Page 60 UPER ERVER 6038R-TXR User's Manual Chapter 7: BIOS • Warning: Enabling ASPM support may cause some PCI-E devices to fail! ME Firmware Status #1 • ME Firmware Status #2 MMIOHBase Use this item to select the base memory size according to memory-address map- •...
  • Page 61 UPER ERVER 6038R-TXR User's Manual Chapter 7: BIOS Serial Port 1 Configuration/Serial Port 2 Configuration COM1 Console Redirection Settings  Serial Port 1/Serial Port 2 Terminal Type Select Enabled to enable the onboard serial port specified by the user. The options This feature allows the user to select the target terminal emulation type for Con- are Enabled and Disabled.
  • Page 62 UPER ERVER 6038R-TXR User's Manual Chapter 7: BIOS Recorder Mode Select VT-UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes. The options are ANSI, VT100, VT100+, and VT-UTF8. Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server.
  • Page 63 UPER ERVER 6038R-TXR User's Manual Chapter 7: BIOS Resolution 100x31 and function key support. Select ANSI to use the extended ASCII character set. Select VT-UTF8 to use UTF8 encoding to map Unicode characters into one or Select Enabled for extended-terminal resolution support. The options are Dis- more bytes.
  • Page 64: Event Logs

    UPER ERVER 6038R-TXR User's Manual Chapter 7: BIOS Event Logs Trusted Computing (Available when a TPM device is installed and detected by the BIOS) Use this feature to configure Event Log settings. Configuration Security Device Support If this feature and the TPM jumper on the motherboard are both set to Enabled, onboard security devices will be enabled for TPM support to enhance data integrity and network security.
  • Page 65: Ipmi

    UPER ERVER 6038R-TXR User's Manual Chapter 7: BIOS IPMI SMBIOS Event Log Standard Settings Log System Boot Event Use this feature to configure Intelligent Platform Management Interface (IPMI) settings. Select Enabled to log system boot events. The options are Disabled and Enabled. MECI (Multiple Event Count Increment) Enter the increment value for the multiple event counter.
  • Page 66: Bmc Network Configuration

    UPER ERVER 6038R-TXR User's Manual Chapter 7: BIOS BMC Network Configuration  The following items will be displayed: • IPMI LAN Selection • IPMI Network Link Status Update IPMI LAN Configuration Select Yes for the BIOS to automatically reset the following IPMI settings at next system boot.
  • Page 67: Security Settings

    UPER ERVER 6038R-TXR User's Manual Chapter 7: BIOS Secure Boot Menu  Security Settings Secure Boot This menu allows the user to configure the following security settings for the system. Select Enable for secure boot support to ensure system security at bootup. The options are Enabled and Disabled.
  • Page 68: Boot Settings

    UPER ERVER 6038R-TXR User's Manual Chapter 7: BIOS Boot Settings  Append KEK (Key Exchange Key) Select <Yes> to load the new KEK from the manufacture defaults. Select <No> to Use this feature to configure Boot Settings: load the new KEK from other sources. Authorized Signatures ...
  • Page 69: Save & Exit

    UPER ERVER 6038R-TXR User's Manual Chapter 7: BIOS Save & Exit  Delete Boot Option Use this item to select a boot device to delete from the boot priority list. Select the Save & Exit tab from the BIOS setup screen to configure the settings below.
  • Page 70 UPER ERVER 6038R-TXR User's Manual Restore Defaults Select Restore Defaults from the Exit menu and press <Enter> to load manufacture default settings for your system to maximize system performance but not stability. Save As User Defaults Select Save as User Defaults from the Exit menu and press <Enter> to save changes to the BIOS setup for future use.
  • Page 71: Appendix A Bios Error Beep Codes

    Appendix A: BIOS POST Error Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed at each system boot, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue to boot.
  • Page 72 UPER ERVER 6038R-TXR User's Manual Notes...
  • Page 73: Appendix B System Specifications

    Appendix B: System Specifications Appendix B System Specifications Processors Two E5-2600 v3/v4 series processors in LGA 2011 sockets (Socket R3) Note: Please refer to our web site for a complete listing of supported processors. Chipset Intel C612 chipset BIOS 16 MB AMIBIOS® SPI Flash ROM Memory Capacity Sixteen DIMM slots that can support up to 2 TB of ECC LRDIMM (Load Reduced DIMM) or 512 GB of ECC RDIMM (Registered DIMM) DDR4-...
  • Page 74 Appendix B: System Specifications UPER ERVER 6038R-TXR User's Manual Chassis SC835XTQ-R982B (3U rackmount) Dimensions: (WxHxD) 17.7 x 5.2 x 25.6 in. (450 x 132 x 650 mm) Weight (Gross Weight) 72.6 lbs. (33 kg.) System Cooling Three 8-cm system fans and one 8-cm rear exhaust fan System Input Requirements AC Input Voltage: 100 - 240V AC auto-range Rated Input Current: 12-8A (100-140 V);...
  • Page 75 Notes (continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency com- munication devices or other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage.