Powerex STSV0302 Operating & Maintenance Manual

Vertical scroll tankmount compressors

Advertisement

Quick Links

Vertical Scroll Tankmount Compressors
Operating & Maintenance Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product
described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal
injury and/or property damage! Retain instructions for future reference.
Powerex • 150 Production Drive • Harrison, OH 45030 • USA
IN600101AV • November 2024
P 1.888.769.7979 • F 513.367.3125 • www.powerexinc.com
Page 1 of 20

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the STSV0302 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Powerex STSV0302

  • Page 1 Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Powerex • 150 Production Drive • Harrison, OH 45030 • USA IN600101AV • November 2024 P 1.888.769.7979 •...
  • Page 3: Table Of Contents

    Maintenance Schedule ..............................8 Wiring Diagram ................................10 Replacement Parts List ..............................13 Powerex Warranty ................................ 18 Powerex • 150 Production Drive • Harrison, OH 45030 • USA IN600101AV • November 2024 P 1.888.769.7979 • F 513.367.3125 • www.powerexinc.com Page 3 of 20...
  • Page 4: Performance & Specification

    Outlet Air Connections ½" FNPT Overpressure Protection ASME safety valve factory set and sealed Powerex • 150 Production Drive • Harrison, OH 45030 • USA IN600101AV • November 2024 P 1.888.769.7979 • F 513.367.3125 • www.powerexinc.com Page 4 of 20...
  • Page 5: General & Safety Guidelines

    10,000 hours of operation. On high pressure units, the tip seal should be replaced every 5,000 hours of operation. Powerex • 150 Production Drive • Harrison, OH 45030 • USA IN600101AV • November 2024 P 1.888.769.7979 • F 513.367.3125 • www.powerexinc.com...
  • Page 6: Installation

    3. Never install the compressor where the ambient temperature is higher than 104°F or where humidity is high. Powerex • 150 Production Drive • Harrison, OH 45030 • USA IN600101AV • November 2024 P 1.888.769.7979 • F 513.367.3125 • www.powerexinc.com...
  • Page 7: Operation

    3. Confirm that the electric power source and ground have been firmly connected. 4. Be sure all pressure connections are tight. Powerex • 150 Production Drive • Harrison, OH 45030 • USA IN600101AV • November 2024 P 1.888.769.7979 • F 513.367.3125 • www.powerexinc.com...
  • Page 8: Maintenance Schedule

    Proper belt tension is just enough to prevent slippage. See following section on belt tensioning method. 4. See Compressor Pump Manuals for replacement or service procedures. Powerex • 150 Production Drive • Harrison, OH 45030 • USA IN600101AV • November 2024 P 1.888.769.7979 • F 513.367.3125 • www.powerexinc.com...
  • Page 9 Each month (see dry- Switch dryer online/ Desiccant dryer Monthly er manual for mainte- offline nance instructions) Powerex • 150 Production Drive • Harrison, OH 45030 • USA IN600101AV • November 2024 P 1.888.769.7979 • F 513.367.3125 • www.powerexinc.com Page 9 of 20...
  • Page 10: Wiring Diagram

    Operating & Maintenance Manual Electrical Wiring Diagram Simplex - 3HP Simplex Single Phase 208-230 Volts Powerex • 150 Production Drive • Harrison, OH 45030 • USA IN600101AV • November 2024 P 1.888.769.7979 • F 513.367.3125 • www.powerexinc.com Page 10 of 20...
  • Page 11 Operating & Maintenance Manual Electrical Wiring Diagram Simplex - 3-5HP Simplex 3 Phase 208/230/460 Volts Powerex • 150 Production Drive • Harrison, OH 45030 • USA IN600101AV • November 2024 P 1.888.769.7979 • F 513.367.3125 • www.powerexinc.com Page 11 of 20...
  • Page 12 Operating & Maintenance Manual Electrical Wiring Diagram Duplex - 3-5HP Duplex 3 Phase 208/230/460 Volts Powerex • 150 Production Drive • Harrison, OH 45030 • USA IN600101AV • November 2024 P 1.888.769.7979 • F 513.367.3125 • www.powerexinc.com Page 12 of 20...
  • Page 13: Replacement Parts List

    V-215106AV Pressure Switch Standard Pressure CW207573AV High Pressure CW207595AV 1/2" FNPT Air Regulator ST178409AJ Powerex • 150 Production Drive • Harrison, OH 45030 • USA IN600101AV • November 2024 P 1.888.769.7979 • F 513.367.3125 • www.powerexinc.com Page 13 of 20...
  • Page 14 V-215106AV Pressure Switch Standard Pressure CW207573AV High Pressure CW207595AV 1/2" FNPT Air Regulator ST178409AJ Powerex • 150 Production Drive • Harrison, OH 45030 • USA IN600101AV • November 2024 P 1.888.769.7979 • F 513.367.3125 • www.powerexinc.com Page 14 of 20...
  • Page 15 After-Filter Element NDR010 ST178184AV ST178185AV NDR015 ST178184AV ST178185AV NDR025 ST178184AV ST178185AV NDR035 ST178108AV ST178109AV Powerex • 150 Production Drive • Harrison, OH 45030 • USA IN600101AV • November 2024 P 1.888.769.7979 • F 513.367.3125 • www.powerexinc.com Page 15 of 20...
  • Page 16 Vertical Scroll Tankmount Compressors Operating & Maintenance Manual Notes Powerex • 150 Production Drive • Harrison, OH 45030 • USA IN600101AV • November 2024 P 1.888.769.7979 • F 513.367.3125 • www.powerexinc.com Page 16 of 20...
  • Page 17 Vertical Scroll Tankmount Compressors Operating & Maintenance Manual Notes Powerex • 150 Production Drive • Harrison, OH 45030 • USA IN600101AV • November 2024 P 1.888.769.7979 • F 513.367.3125 • www.powerexinc.com Page 17 of 20...
  • Page 18: Powerex Warranty

    Powerex warrants and represents all Products shall be free from Defects for the first thirty (30) months from the date of shipment by Powerex, or twenty-four (24) months from the documented date of startup, or seven thousand five hundred (7,500) hours of use, whichever occurs first.
  • Page 19 Powerex after any initial warranty period has expired or where another warranty does not apply for any reason, Powerex warrants that the Air-End or Vacuum Pumps shall be free of Defects for the first twelve (12) months from the date of shipment by Powerex. Supplier’s repair or replacement of any Product shall not extend the period of any warranty of any Product.
  • Page 20 Prices, discounts, and terms are subject to change without notice or as stipulated in specific Product quotations. Powerex shall not be liable for any delay or failure arising out of acts of the public enemy, fire, flood, or any disaster, labor trouble, riot or disorder, delay in the supply of materials or any other cause, whether similar or dissimilar, beyond the control of Company.

This manual is also suitable for:

Stsv1302Stsv0502Stdv0303Stdv0503

Table of Contents