NOTE: LED= Light Emitting Diode
LABELING EXPLANATION:
X: Self contained
0: Non Maintained (*)
A:
Including test device
F: Automatic test gear complying with IEC 61347-2-7 denoted EL-T
180: 3 hours duration
X 0 A F
1
8
0
(*) Non Maintained operation: The luminaire lights its illumination source, only in power supply's
failure.
The light source contained in this luminaire shall only be replaced by the manufacturer, or his
agent, or a similar qualified person.
NOTE! The light source is non-user replaceable.
LED MODULE CHARACTERISTICS
Manufacturer
Model Number
Voltage Range
Nominal Power
Cable connection between main pcb and led module
Connections
Temperature (tc)
WARRANTY
Olympia Electronics guarantees the quality, condition and operation of the goods. The period of warranty
is specified in the official catalogue of Olympia Electronics and also in the technical leaflet, which
accompanies each product. This warranty ceases to exist if the buyer does not follow the technical
instructions included in official documents given by Olympia Electronics or if the buyer modifies the goods
provided or has any repairs or re-setting done by a third party, unless Olympia Electronics has fully agreed
to them in writing. Products that have been damaged can be returned to the premises of our company for
repair or replacement, as long as the warranty period is valid.
Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge the
buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or not the
buyer the transportation cost.
HEAD OFFICE
72
nd
km. O.N.R. Thessaloniki-Katerini
P.C. 60300 P.O. Box 06 Εginio Pierias Greece
www.olympia-electronics.com
info@olympia-electronics.gr
Page 4 from 4
Olympia Electronics S.A.
2002163
19-23V
4.9W
60 °C max. across the board
923029019_09_001
WATERPROOF SELF TESTING NON MAINTAINED EMERGENCY LUMINAIRE
TECHNICAL CHARACTERISTICS
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERY (LiFePO )
4
BATTERY PROTECTION
INDICATIONS - CONTROLS
POWER-CHARGE indicator, LAMP FAULT–BATT. FAULT indicator, TEST button
CHARGING TIME
MINIMUM AUTONOMOUS DURATION
LIGHT SOURCE
EMERGENCY ILLUMINATION
DEGREES OF COVER PROTECTION
EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
CONSTRUCTION MATERIALS
EXTERNAL DIMENSIONS
TYPICAL WEIGHT
GUARANTEE
Thank you for your trust in our products
Olympia Electronics - European manufacturer
GENERAL
These luminaires are used indoors (ta 60 C)
where emergency light is needed. Each
luminaire must be connected permanently to
the mains power supply.
OPERATION DESCRIPTION
When the unit is connected to the mains power
supply (after connecting the battery) the
indicator LAMP FAULT – BATT. FAULT remains
OFF whereas the indicator POWER CHARGE
blinks to indicate that the batteries are charging.
When the batteries are fully charged this
indicator will light permanently. If this indicator
does not light then probably the battery has not
been connected. If the batteries are connected
and the indicator does not light then contact a
qualified service technician for assistance. The
charging procedure is monitored by a
microprocessor and is based on a 3 stage cycle
thus ensuring a fast and full charge of the battery.
The charge current is supplied by a high
efficiency switch mode power supply which
ensures perfect charging even during the
fluctuations of the mains power supply.
BATTERY CUTOFF
The unit enters this state during the power
Page 1 from 4
(for LED MODULE Specifications see page 4)
GRL-29/WP/LF
220-240V AC/50-60Hz
8.2W/8.7VA
12.8V/5Ah
From overcharge and deep discharge
16h
180 min
White LEDs
1760lm
IP65
o
0 to 60 C
Up to 95%
ABS/PC, PC
302 x 94 x 345 mm
2250gr.
10 years
supply failure and when the battery has been
o
fully discharged. In this state the luminaire draws
the least power from the battery in order to
prevent deep discharge.
MANUAL TESTING
Is accomplished by briefly (<1 sec.) pressing the
TEST button. This permits the user to test the
good operation of the luminaire's emergency
circuit. The unit simulates a power failure and the
lamps are lit using the batteries. This manual test
does not affect the automatic test.
DIMMING OPTION
When the luminaire is in emergency mode, with
corresponding pressings of the button, we can
choose the illumination of 100%, 50%, 33% or
turned off, either to increase the autonomy time
or not to consume the battery power
unnecessarily. This option is canceled when the
network is restored.
LAMP TESTING
The luminaire tests the good condition of the
lamps in emergency mode and warns the user
for probable malfunction. If a lamp is found faulty
then the LAMP FAULT indicator starts to blink. To
verify which lamp is faulty use the TEST button. If
923029019_09_001