SELF TESTING NON-MAINTAINED EMERGENCY CEILING MOUNTED LUMINAIRES WITH WIRELESS COMMUNICATION
TECHNICAL CHARACTERISTICS
OPERATION VOLTAGE
MAX. SUPPLY CURRENT
MAXIMUM POWER CONSUMPTION
MINIMUM POWER FACTOR (λ)
U-OUT
BATTERY
INSULATION BETWEEN SUPPLY & CONTROL TERMINALS
INSULATION BETWEEN SUPPLY & BATTERY CIRCUIT
WORKING VOLTAGE AT WHICH THE INSULATION IS DESIGNED
BATTERY PROTECTION
BATTERY VOLTAGE RANGE
BATTERY SUPPLY CURRENT DURING EMERGENCY
BATTERY CHARGE CURRENT RANGE
BATTERY DISCHARGE CURRENT RANGE
TX/RX FREQUENCY RANGE
TX POWER
INDICATIONS - CONTROLS
CHARGE TIME
MINIMUM DURATION
LIGHT SOURCE
EMERGENCY ILLUMINATION
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
Prated/Irated
CONTROL GEAR MAX.TEMPERATURE (tc)
RELATIVE HUMIDITY
CONSTRUCTION MATERIAL
EXTERNAL DIMENSION
WEIGHT
GUARANTEE
CONTROL GEAR WITH AUTOMATIC
TEST FUNCTION
Controlgear is suitable for LED module only
The controlgear has mains-connected windings of transformer
GENERAL
This device is used indoors (ta 40 C) in places
where emergency luminaires are needed. Each
device must be permanently connected to mains
power supply. The luminaire GR-292/M/HL/WL
is suitable for corridors lighting and the GR-
293/M/HL/WL for open area lighting. In normal
operation the battery is charging. In case of a
mains power supply failure, the device enters
emergency mode and the illumination LED turns
on. When the mains power supply is restored,
the device turns to normal operation.
Page 1 from 6
GR-292/M/HL/WL
130 - 200mA (normal charge) / 20 - 30mA (trickle charge)
ΕΝ 61000-3-3, ETSI EN 303 446-1 v1.1.0, ETSI EN 300 220-2 v3.1.1
Thank you for your trust in our products
Olympia Electronics - European manufacturer
o
(for LED MODULE specifications see page 6)
220-240V AC / 50-60Hz
19.5mA AC
4.9W / 5.2 VA
4.8V/4Ah, NiMH (4KRMT 23/62)
Basic insulation
Basic insulation
500V
Deep discharge and overcharge protection
(Vbat=4.8V):650mA
550 - 730mA
868.150-868.450MHz
11dBm
Charge, lamp fault, battery fault, TEST button
24 hours
3 hours
1 white power LED
330lm
EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2,
5 to 40 C
2.3W/760mA
80°C at Q2
Up to 95%
ABS/PC
Ø125 x 72 mm
737gr.
3 years (1 year for the battery)
Battery Charging
The battery charging is completely controlled. In
this case, is achieved the perfect
maintenance , as well as the elongation of its
duration. When the battery has completely
charged, it charges with a maintenance current.
Battery charge failure due to shortcut
The recharging device will recharge the battery
normally after the short circuit is removed and the
batterie(s) are reinstalled.
GR-293/M/HL/WL
0.9
6V
4-6V
IP20
o
923292009_09_001
battery